Back to results

Virginia Tech

Experimental Investigations of Residual Strength and Repaired Strength of Corrosion Damaged Prestressed Bridge Beams

Abstract

dc:description.abstract

The durability of infrastructure components, such as prestressed concrete bridge beams, can be significantly affected by long-term deterioration associated with corrosion. Corrosion is a major concern for bridges in Virginia, due to the frequent use of deicing salts during the winter, as well as the number of structures in marine environments. The residual capacity of corrosion damaged prestressed I-beams and box beams needs to be accurately estimated to determine if damaged bridges need to be posted, and to help with making informed decisions related to repair, rehabilitation and replacement of damaged bridges. The initial stage of the research investigated the ability to determine the in-situ strength of members that have visible corrosion-related damage. In this stage, six corrosion-damaged beams were investigated. Prior to testing, the beams were visually inspected and damage was documented. The beams were then tested in the lab to determine their flexural strength. Following testing, samples of strands were removed and tested to determine their tensile properties while cores were taken to determine compressive strength. Powdered concrete samples were removed to perform chloride concentration tests. The tested strengths of the beams were compared to calculated strengths using two methods for damage estimation and two different calculation approaches. Two repair methods were then evaluated through large-scale experimental testing, aimed at restoring the strength of deteriorated prestressed concrete beams. The investigated repairs included External Post-Tensioning (PT) and Carbon Fiber Reinforced Polymer (CFRP) laminates applied to the bottom flange of beams for flexural strengthening. A total of five full-scale bridge members were tested to failure throughout this stage. All beams were subjected to monotonically increasing loads until failure. For beams repaired with external PT, the experimental test was accompanied by a detailed approach for determining the ultimate failure load, the ultimate stress in the external tendons, and the location of the failure. For beams repaired with CFRP, the experimental test was accompanied by a parametric study that was performed to determine the maximum reduction in flexural strength for which CFRP can be considered as a viable repair method to restore the lost capacity. This dissertation provides additional information on estimating the residual capacity of corrosion-damaged beams and shows the types of repair that can restore their original strength. With this information, Departments of Transportation (DOT) can properly determine what types of repair are a suitable for the damaged girders based on their level of corrosion.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Civil Engineering
Department dc:contributor.department
Civil and Environmental Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Alfailakawi, Ali
Chairs dc:contributor.committeechair
  • Hebdon, Matthew Hardy
  • Roberts-Wollmann, Carin L.
Committee members dc:contributor.committeemember
  • Koutromanos, Ioannis
  • Mokarem, David Wayne

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:35287
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/111389

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Alfailakawi, Ali. Experimental Investigations of Residual Strength and Repaired Strength of Corrosion Damaged Prestressed Bridge Beams. doctoral thesis, Virginia Tech, 2022. http://hdl.handle.net/10919/111389