Back to results

Virginia Tech

Desing of the high Pressure HIgh temperature annuLUS flow (PHILUS) Facility

Abstract

dc:description.abstract

Critical heat flux (CHF) and post-CHF are two critical phenomena in light water-cooled nuclear power plants regarding safety. Even though the general trends of CHF and post- CHF are known, the exact mechanisms are still unknown. To better understand CHF and post-CHF, experimental flow boiling facilities are constructed around the world. However, these facilities are limited in their experimental conditions and spatial resolution necessary to advance our understanding of two-phase heat transfer. Previous rod surface measurements were collected with thermocouples to measure CHF location and temperature excursion, yet thermocouples provide limited spatial resolution, which leads to significant uncertainties in the CHF prediction. On the other hand, optical fiber temperature sensors can measure the temperature and the CHF propagation with high spatial resolution. Also, the capability of the optical fiber at high temperatures has been proven in previous studies. The current study aims to apply optical fiber at high-pressure and high mass fluxes. The high-Pressure HIgh-temperature annuLUS flow (PHILUS) facility was designed to provide desired working conditions in the test section that uses optical fiber temperature sensors. The PHILUS test section has a length of 1320 mm, with 1000 mm of heated length. The working conditions of the PHILUS are up to 18 MPa, temperatures up to 357◦C, and coolant mass flux from 500 to 3700 kg/m2s. The main components of the loop are a steam separator, two heat exchangers (a condenser and a cooler), a bladder-type accumulator, two bypass lines, and a high-pressure pump. Coolant-Boiling in Rod Arrays-Two Fluids (COBRA-TF) code was used to design the CHF and post-CHF experiments to be performed at the PHILUS facility.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Nuclear Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Karabacak, Ali Haydar
Chair dc:contributor.committeechair
  • Pacheco Duarte, Juliana
Committee members dc:contributor.committeemember
  • Pierson, Mark Alan
  • Liu, Yang

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:35075
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/110838

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Karabacak, Ali Haydar. Desing of the high Pressure HIgh temperature annuLUS flow (PHILUS) Facility. masters thesis, Virginia Tech, 2022. http://hdl.handle.net/10919/110838