{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/104288"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/104288","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"A rapidly scanning three-velocity-component laser Doppler anemometer","abstract":"A rapidly scanning directionally-sensitive three-velocity - component laser Doppler anemometer has been developed. It permits scans through 3-dimensional flows to obtain space-time velocity information. Since it has lower signal-averaging bias than pointwise measurements, only short record times are required to obtain sufficient data for statistical averages and, hence, it enables rapid mapping of the U, V, and W velocities in such flows. A flexible optical system allows for easy variation of the fringe spacings as well as the location and the size of the measurement volume. The optical paths are equalized without use of any additional optical components. A Ronchi Ruling is employed to create a horizontal stationary fringe pattern, and a dual Bragg cell is used to produce sets of moving vertical fringes. It is also shown that a scheme proposed by other workers, relying on a fringe pattern moving in the on-axis direction, will not work. The Doppler frequency is independent of the position of the receiving optics, and only one photomultiplier tube is needed to receive the signals for all three velocity components. Measurements made on a stationary solid object as well as in a dispersion of particles in water show that signals with low noise level and high fringe visibility are obtained.","abstract_html":"A rapidly scanning directionally-sensitive three-velocity - component laser Doppler anemometer has been developed. It permits scans through 3-dimensional flows to obtain space-time velocity information. Since it has lower signal-averaging bias than pointwise measurements, only short record times are required to obtain sufficient data for statistical averages and, hence, it enables rapid mapping of the U, V, and W velocities in such flows. A flexible optical system allows for easy variation of the fringe spacings as well as the location and the size of the measurement volume. The optical paths are equalized without use of any additional optical components. A Ronchi Ruling is employed to create a horizontal stationary fringe pattern, and a dual Bragg cell is used to produce sets of moving vertical fringes. It is also shown that a scheme proposed by other workers, relying on a fringe pattern moving in the on-axis direction, will not work. The Doppler frequency is independent of the position of the receiving optics, and only one photomultiplier tube is needed to receive the signals for all three velocity components. Measurements made on a stationary solid object as well as in a dispersion of particles in water show that signals with low noise level and high fringe visibility are obtained.","abstract_has_math":false,"creators":["Antoine, Marc M. E."],"institution":"Virginia Polytechnic Institute and State University","degree_name":"M.S.","degree_level":"masters","degree_discipline":"Aerospace and Ocean Engineering","degree_department":"Aerospace and Ocean Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1985,"date_issued":"1985","date_published":"1985","updated_at":"2026-07-22T22:19:32Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/104288","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Aerospace and Ocean Engineering"]},{"key":"dc:creator","label":"Author","values":["Antoine, Marc M. E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-07-22T18:16:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-07-22T18:16:10Z"]},{"key":"dc:date.issued","label":"Date","values":["1985"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aerospace and Ocean Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/104288"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A rapidly scanning directionally-sensitive three-velocity - component laser Doppler anemometer has been developed. It permits scans through 3-dimensional flows to obtain space-time velocity information. Since it has lower signal-averaging bias than pointwise measurements, only short record times are required to obtain sufficient data for statistical averages and, hence, it enables rapid mapping of the U, V, and W velocities in such flows. A flexible optical system allows for easy variation of the fringe spacings as well as the location and the size of the measurement volume. The optical paths are equalized without use of any additional optical components. A Ronchi Ruling is employed to create a horizontal stationary fringe pattern, and a dual Bragg cell is used to produce sets of moving vertical fringes. It is also shown that a scheme proposed by other workers, relying on a fringe pattern moving in the on-axis direction, will not work. The Doppler frequency is independent of the position of the receiving optics, and only one photomultiplier tube is needed to receive the signals for all three velocity components. Measurements made on a stationary solid object as well as in a dispersion of particles in water show that signals with low noise level and high fringe visibility are obtained."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A rapidly scanning three-velocity-component laser Doppler anemometer"]}]}],"canonical_facts":{"dc:contributor.department":["Aerospace and Ocean Engineering"],"dc:creator":["Antoine, Marc M. E."],"dc:date.accessioned":["2021-07-22T18:16:10Z"],"dc:date.available":["2021-07-22T18:16:10Z"],"dc:date.issued":["1985"],"dc:description.abstract":["A rapidly scanning directionally-sensitive three-velocity - component laser Doppler anemometer has been developed. It permits scans through 3-dimensional flows to obtain space-time velocity information. Since it has lower signal-averaging bias than pointwise measurements, only short record times are required to obtain sufficient data for statistical averages and, hence, it enables rapid mapping of the U, V, and W velocities in such flows. A flexible optical system allows for easy variation of the fringe spacings as well as the location and the size of the measurement volume. The optical paths are equalized without use of any additional optical components. A Ronchi Ruling is employed to create a horizontal stationary fringe pattern, and a dual Bragg cell is used to produce sets of moving vertical fringes. It is also shown that a scheme proposed by other workers, relying on a fringe pattern moving in the on-axis direction, will not work. The Doppler frequency is independent of the position of the receiving optics, and only one photomultiplier tube is needed to receive the signals for all three velocity components. Measurements made on a stationary solid object as well as in a dispersion of particles in water show that signals with low noise level and high fringe visibility are obtained."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10919/104288"],"dc:language.iso":["en"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:title":["A rapidly scanning three-velocity-component laser Doppler anemometer"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Aerospace and Ocean Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:32Z"}