{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/10072"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/10072","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Low Frequency Modeling and Experimental Validation of Passive Noise Attenuation in Ear Defenders","abstract":"Circumaural ear cups have been used for decades as an effective way of protecting users from high noise fields. Over the decades, a number of researchers dedicated their time to understanding the dynamics that govern the attenuation of hearing protectors. This thesis duplicates some of this work with newer technology and better data processing ability. In addition to revitalizing the accepted knowledge of hearing protector technology, this thesis is the first documented effort to show how the previously ignored air leak, known to exist between the ear cup and the head, has a profound effect on the low and mid frequency attenuation of a circumaural hearing defender. Past research focused on the mechanical vibration of the cup on the seal as the main source of noise within the ear cup. This mechanical vibration, known as the piston resonance exists, and affected noise attenuation within the ear cup. A reasonably sized air leak of 160 e-7 m2 however, overwhelmed the piston resonance. An air leak of this size was shown to degrade noise attenuation by over 50 dB at 40Hz and 30 dB at 200 Hz when compared to a no-leak case. Further testing also suggested that the air leak has the ability to continue adding energy into the cup up to 3000 Hz.","abstract_html":"Circumaural ear cups have been used for decades as an effective way of protecting users from high noise fields. Over the decades, a number of researchers dedicated their time to understanding the dynamics that govern the attenuation of hearing protectors. This thesis duplicates some of this work with newer technology and better data processing ability. In addition to revitalizing the accepted knowledge of hearing protector technology, this thesis is the first documented effort to show how the previously ignored air leak, known to exist between the ear cup and the head, has a profound effect on the low and mid frequency attenuation of a circumaural hearing defender. Past research focused on the mechanical vibration of the cup on the seal as the main source of noise within the ear cup. This mechanical vibration, known as the piston resonance exists, and affected noise attenuation within the ear cup. A reasonably sized air leak of 160 e-7 m2 however, overwhelmed the piston resonance. An air leak of this size was shown to degrade noise attenuation by over 50 dB at 40Hz and 30 dB at 200 Hz when compared to a no-leak case. Further testing also suggested that the air leak has the ability to continue adding energy into the cup up to 3000 Hz.","abstract_has_math":false,"creators":["Sides, Jonathan Drapala"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Saunders, William R."],"committee_members":["Burdisso, Ricardo A.","West, Robert L. Jr."],"year":2004,"date_issued":"2004-08-06","date_published":"2004-08-06","updated_at":"2026-07-22T22:18:53Z","subjects":["Attenuation","Defender","Frequency","Noise","Passive","Ear"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-08202004-100252"],"render_values":[{"text":"etd-08202004-100252","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/10072","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Saunders, William R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Burdisso, Ricardo A.","West, Robert L. Jr."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Sides, Jonathan Drapala"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-08-06T16:05:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-08-06T16:05:50Z","2004-08-20"]},{"key":"dc:date.issued","label":"Date","values":["2004-08-06"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Attenuation","Defender","Frequency","Noise","Passive","Ear"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-08202004-100252"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/10072"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Circumaural ear cups have been used for decades as an effective way of protecting users from high noise fields. Over the decades, a number of researchers dedicated their time to understanding the dynamics that govern the attenuation of hearing protectors. This thesis duplicates some of this work with newer technology and better data processing ability. In addition to revitalizing the accepted knowledge of hearing protector technology, this thesis is the first documented effort to show how the previously ignored air leak, known to exist between the ear cup and the head, has a profound effect on the low and mid frequency attenuation of a circumaural hearing defender. Past research focused on the mechanical vibration of the cup on the seal as the main source of noise within the ear cup. This mechanical vibration, known as the piston resonance exists, and affected noise attenuation within the ear cup. A reasonably sized air leak of 160 e-7 m2 however, overwhelmed the piston resonance. An air leak of this size was shown to degrade noise attenuation by over 50 dB at 40Hz and 30 dB at 200 Hz when compared to a no-leak case. Further testing also suggested that the air leak has the ability to continue adding energy into the cup up to 3000 Hz."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Low Frequency Modeling and Experimental Validation of Passive Noise Attenuation in Ear Defenders"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Saunders, William R."],"dc:contributor.committeemember":["Burdisso, Ricardo A.","West, Robert L. Jr."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Sides, Jonathan Drapala"],"dc:date.accessioned":["2011-08-06T16:05:50Z"],"dc:date.available":["2011-08-06T16:05:50Z","2004-08-20"],"dc:date.issued":["2004-08-06"],"dc:description.abstract":["Circumaural ear cups have been used for decades as an effective way of protecting users from high noise fields. Over the decades, a number of researchers dedicated their time to understanding the dynamics that govern the attenuation of hearing protectors. This thesis duplicates some of this work with newer technology and better data processing ability. In addition to revitalizing the accepted knowledge of hearing protector technology, this thesis is the first documented effort to show how the previously ignored air leak, known to exist between the ear cup and the head, has a profound effect on the low and mid frequency attenuation of a circumaural hearing defender. Past research focused on the mechanical vibration of the cup on the seal as the main source of noise within the ear cup. This mechanical vibration, known as the piston resonance exists, and affected noise attenuation within the ear cup. A reasonably sized air leak of 160 e-7 m2 however, overwhelmed the piston resonance. An air leak of this size was shown to degrade noise attenuation by over 50 dB at 40Hz and 30 dB at 200 Hz when compared to a no-leak case. Further testing also suggested that the air leak has the ability to continue adding energy into the cup up to 3000 Hz."],"dc:description.degree":["Master of Science"],"dc:format.medium":["ETD"],"dc:identifier.other":["etd-08202004-100252"],"dc:identifier.uri":["http://hdl.handle.net/10919/10072"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Attenuation","Defender","Frequency","Noise","Passive","Ear"],"dc:title":["Low Frequency Modeling and Experimental Validation of Passive Noise Attenuation in Ear Defenders"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:18:53Z"}