Back to results

Institutional Repository of Vilnius University

Pilvinės aortos aneurizmos automatinės detekcijos nauda matuojant aneurizmos tūrį. Literatūros apžvalga ir modelio sukūrimas /

Abstract

dc:description

For almost 20 years, aortic diameter has been the main parameter used not only for diagnosing aortic aneurysms, but also for surveillance, clinical decision-making and follow-ups after interventions. Despite its widespread use, diameter measurement has some relevant limitations. Therefore, aortic aneurysm volume measurement has recently been reported as a superior and more accurate method than diameter. Although volume measurement excels in detecting aneurysm sac changes post-endovascular interventions and more accurately reflects aneurysm growth, it still not used in daily clinical practice due to technical limitations. Given that high time consumption is considered the primary drawback of volume measurement, leading to a mismatch between workload and workforce, this study aimed to compare the time consumption of manual and fully automatic aortic aneurysm volume measurement. Ten sets of abdominal and pelvic computed tomography angiography (CTA) images from 10 patients with abdominal aortic aneurysms (totaling 20 CTA image series) were utilized. Aortic and common iliac artery volumes were calculated manually in all patients using the 3mensio and OsiriX software and automatically using the EndoArt artificial intelligence algorithm. The time consumption for each measurement was recorded and then compared. Statistically significantly higher time costs were observed for manual volume calculation compared to fully automatic measurement (p<0.001, based on Wilcoxon's criterion). These findings highlight the benefits of automatic aortic aneurysm volume measurement. Implementing automatic volume measurement in clinical practice would save time, mitigate the mismatch between workload and workforce, and enable more accurate detection of small yet clinically relevant aneurysm size changes.

Degree

thesis:*
Grantor dc:publisher
Institutional Repository of Vilnius University
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Račytė, Austėja,

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
lit

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:vu.lt:elaba:210540578

Chain of custody

source
Harvested from
Vilnius University
Base URL
epublications.vu.lt/oai
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Račytė, Austėja,. Pilvinės aortos aneurizmos automatinės detekcijos nauda matuojant aneurizmos tūrį. Literatūros apžvalga ir modelio sukūrimas /. Institutional Repository of Vilnius University, 2024. https://repository.vu.lt/VU:ELABAETD210540578&prefLang=en_US