{"id":{"repo_id":"vcu","oai_identifier":"oai:scholarscompass.vcu.edu:etd-1900"},"canonical_url":"https://search.dev.ndltd.org/etd/vcu/oai:scholarscompass.vcu.edu:etd-1900","repository":{"repo_id":"vcu","name":"Virginia Commonwealth University","base_url":"https://scholarscompass.vcu.edu/do/oai/"},"display":{"title":"Characterization of Perphenazine and Scopolamine Aerosols Generated Using the Capillary Aerosol Generator","abstract":"The characterization of perphenazine and scopolamine aerosols generated using the capillary aerosol generator (CAG) was reported. Variables including steady state power, the formulation vehicle, the drug concentration and the formulation flow rate were studied for their effects on the chemical stability and particle size of these drug aerosols.Stability-indicating HPLC and LC-MS assays were developed and validated for perphenazine and scopolamine, respectively. The chemical stability of each compound was investigated under a variety of stress conditions and the structure of degradation products was proposed.Perphenazine aerosols were generated from propylene glycol (PG) formulations with concentrations of 9, 48 and 90mM at formulation flow rates of 2.5 and 5.0&#181;L/s at a series of steady state powers. At higher aerosolization powers, the low concentration formulation (9mM) degraded with dehalogenation being the major pathway. The size of perphenazine aerosols was between 0.4 to 0.6&#181;m. Changing the solute concentration produced only small changes (~0.2&#181;m) in perphenazine aerosol particle size. The formulation flow rate did not significantly affect the aerosol size.Scopolamine degraded significantly when aerosolized in PG formulations. It was possible to generate chemically stable scopolamine aerosols from ethanol formulations. Significant amounts of degradation products were formed only at or above 4.6W at 5.0&#181;L/s. Hydrolysis and dehydration appeared to be the major degradation pathways at higher powers and low formulation flow rate. The MMAD of scopolamine aerosols was between 0.5 and 2.0&#181;m from 8, 20 and 40mM formulations at 5.0 and 10.0&#181;L/s. The size of scopolamine aerosols increased as a function of increasing the solute concentration. Increasing the formulation flow rate increased the linear velocity of the spray, thus the Reynolds number was increased and smaller particles were generated.","abstract_html":"The characterization of perphenazine and scopolamine aerosols generated using the capillary aerosol generator (CAG) was reported. Variables including steady state power, the formulation vehicle, the drug concentration and the formulation flow rate were studied for their effects on the chemical stability and particle size of these drug aerosols.Stability-indicating HPLC and LC-MS assays were developed and validated for perphenazine and scopolamine, respectively. The chemical stability of each compound was investigated under a variety of stress conditions and the structure of degradation products was proposed.Perphenazine aerosols were generated from propylene glycol (PG) formulations with concentrations of 9, 48 and 90mM at formulation flow rates of 2.5 and 5.0&amp;#181;L/s at a series of steady state powers. At higher aerosolization powers, the low concentration formulation (9mM) degraded with dehalogenation being the major pathway. The size of perphenazine aerosols was between 0.4 to 0.6&amp;#181;m. Changing the solute concentration produced only small changes (~0.2&amp;#181;m) in perphenazine aerosol particle size. The formulation flow rate did not significantly affect the aerosol size.Scopolamine degraded significantly when aerosolized in PG formulations. It was possible to generate chemically stable scopolamine aerosols from ethanol formulations. Significant amounts of degradation products were formed only at or above 4.6W at 5.0&amp;#181;L/s. Hydrolysis and dehydration appeared to be the major degradation pathways at higher powers and low formulation flow rate. The MMAD of scopolamine aerosols was between 0.5 and 2.0&amp;#181;m from 8, 20 and 40mM formulations at 5.0 and 10.0&amp;#181;L/s. The size of scopolamine aerosols increased as a function of increasing the solute concentration. Increasing the formulation flow rate increased the linear velocity of the spray, thus the Reynolds number was increased and smaller particles were generated.","abstract_has_math":false,"creators":["Li, Xihao"],"institution":null,"degree_name":"Doctor of Philosophy","degree_level":"Dissertation","degree_discipline":"Pharmaceutics","degree_department":null,"school":null,"contributors":["Dr. Michael Hindle"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-01-01T08:00:00Z","date_published":"2006-01-01T08:00:00Z","updated_at":"2026-07-24T05:54:40Z","subjects":["condensation","dehydration","hydrolysis","volatility","flow rate","relative humidity","atomization","mass spectrometry","stability","Medicine and Health Sciences","Pharmacy and Pharmaceutical Sciences"],"languages":[],"rights":["© The Author"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarscompass.vcu.edu/etd/901"],"render_values":[{"text":"https://scholarscompass.vcu.edu/etd/901","href":"https://scholarscompass.vcu.edu/etd/901","code":true}]}]},"links":{"outbound_url":"https://doi.org/10.25772/A1SB-KT37","outbound_label":"DOI","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Michael Hindle"]},{"key":"dc:creator","label":"Author","values":["Li, Xihao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2014-07-09T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Pharmaceutics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["condensation","dehydration","hydrolysis","volatility","flow rate","relative humidity","atomization","mass spectrometry","stability","Medicine and Health Sciences","Pharmacy and Pharmaceutical Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["© The Author"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.25772/A1SB-KT37","https://scholarscompass.vcu.edu/etd/901"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The characterization of perphenazine and scopolamine aerosols generated using the capillary aerosol generator (CAG) was reported. Variables including steady state power, the formulation vehicle, the drug concentration and the formulation flow rate were studied for their effects on the chemical stability and particle size of these drug aerosols.Stability-indicating HPLC and LC-MS assays were developed and validated for perphenazine and scopolamine, respectively. The chemical stability of each compound was investigated under a variety of stress conditions and the structure of degradation products was proposed.Perphenazine aerosols were generated from propylene glycol (PG) formulations with concentrations of 9, 48 and 90mM at formulation flow rates of 2.5 and 5.0&#181;L/s at a series of steady state powers. At higher aerosolization powers, the low concentration formulation (9mM) degraded with dehalogenation being the major pathway. The size of perphenazine aerosols was between 0.4 to 0.6&#181;m. Changing the solute concentration produced only small changes (~0.2&#181;m) in perphenazine aerosol particle size. The formulation flow rate did not significantly affect the aerosol size.Scopolamine degraded significantly when aerosolized in PG formulations. It was possible to generate chemically stable scopolamine aerosols from ethanol formulations. Significant amounts of degradation products were formed only at or above 4.6W at 5.0&#181;L/s. Hydrolysis and dehydration appeared to be the major degradation pathways at higher powers and low formulation flow rate. The MMAD of scopolamine aerosols was between 0.5 and 2.0&#181;m from 8, 20 and 40mM formulations at 5.0 and 10.0&#181;L/s. The size of scopolamine aerosols increased as a function of increasing the solute concentration. Increasing the formulation flow rate increased the linear velocity of the spray, thus the Reynolds number was increased and smaller particles were generated."]},{"key":"dc:title","label":"Title","values":["Characterization of Perphenazine and Scopolamine Aerosols Generated Using the Capillary Aerosol Generator"]}]}],"canonical_facts":{"dc:contributor":["Dr. Michael Hindle"],"dc:creator":["Li, Xihao"],"dc:date.available":["2014-07-09T07:00:00Z"],"dc:description.abstract":["The characterization of perphenazine and scopolamine aerosols generated using the capillary aerosol generator (CAG) was reported. Variables including steady state power, the formulation vehicle, the drug concentration and the formulation flow rate were studied for their effects on the chemical stability and particle size of these drug aerosols.Stability-indicating HPLC and LC-MS assays were developed and validated for perphenazine and scopolamine, respectively. The chemical stability of each compound was investigated under a variety of stress conditions and the structure of degradation products was proposed.Perphenazine aerosols were generated from propylene glycol (PG) formulations with concentrations of 9, 48 and 90mM at formulation flow rates of 2.5 and 5.0&#181;L/s at a series of steady state powers. At higher aerosolization powers, the low concentration formulation (9mM) degraded with dehalogenation being the major pathway. The size of perphenazine aerosols was between 0.4 to 0.6&#181;m. Changing the solute concentration produced only small changes (~0.2&#181;m) in perphenazine aerosol particle size. The formulation flow rate did not significantly affect the aerosol size.Scopolamine degraded significantly when aerosolized in PG formulations. It was possible to generate chemically stable scopolamine aerosols from ethanol formulations. Significant amounts of degradation products were formed only at or above 4.6W at 5.0&#181;L/s. Hydrolysis and dehydration appeared to be the major degradation pathways at higher powers and low formulation flow rate. The MMAD of scopolamine aerosols was between 0.5 and 2.0&#181;m from 8, 20 and 40mM formulations at 5.0 and 10.0&#181;L/s. The size of scopolamine aerosols increased as a function of increasing the solute concentration. Increasing the formulation flow rate increased the linear velocity of the spray, thus the Reynolds number was increased and smaller particles were generated."],"dc:identifier":["https://doi.org/10.25772/A1SB-KT37","https://scholarscompass.vcu.edu/etd/901"],"dc:rights":["© The Author"],"dc:subject":["condensation","dehydration","hydrolysis","volatility","flow rate","relative humidity","atomization","mass spectrometry","stability","Medicine and Health Sciences","Pharmacy and Pharmaceutical Sciences"],"dc:title":["Characterization of Perphenazine and Scopolamine Aerosols Generated Using the Capillary Aerosol Generator"],"thesis:degree_discipline":["Pharmaceutics"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Doctor of Philosophy"]},"updated_at":"2026-07-24T05:54:40Z"}