{"id":{"repo_id":"uwo","oai_identifier":"oai:uwo.scholaris.ca:20.500.14721/36064"},"canonical_url":"https://search.dev.ndltd.org/etd/uwo/oai:uwo.scholaris.ca:20.500.14721/36064","repository":{"repo_id":"uwo","name":"Western University","base_url":"https://uwo.scholaris.ca/server/oai/request"},"display":{"title":"Experimental Analysis of Parameters Influencing the Bone Burring Process","abstract":"The experimental quantification of the bone removal characteristics associated with bone burring represents a desirable outcome mainly for the selection of optimal parameters. An experimental apparatus was developed that allowed for concurrent measurement of three outputs associated with the bone removal process (cutting force, vibration, and temperature) as a function of various burring-specific parameters. Initial process trends were established on a uniform sawbone analog through use of a fully balanced multivariate statistical analysis. A smaller set of optimal and suboptimal parameters were further validated using a porcine femur. From the parameters tested, an optimal tool configuration, to avoid high temperature and high vibration, was found to be a 6 mm sphere burr at a rotational speed of 15,000 rpm, feed rate of 2 mm/s and a path overlap of 50%. This set of parameters also provided flexibility in tool depth/orientation angle relative to the bone without sacrificing optimal process outcomes.","abstract_html":"The experimental quantification of the bone removal characteristics associated with bone burring represents a desirable outcome mainly for the selection of optimal parameters. An experimental apparatus was developed that allowed for concurrent measurement of three outputs associated with the bone removal process (cutting force, vibration, and temperature) as a function of various burring-specific parameters. Initial process trends were established on a uniform sawbone analog through use of a fully balanced multivariate statistical analysis. A smaller set of optimal and suboptimal parameters were further validated using a porcine femur. From the parameters tested, an optimal tool configuration, to avoid high temperature and high vibration, was found to be a 6 mm sphere burr at a rotational speed of 15,000 rpm, feed rate of 2 mm/s and a path overlap of 50%. This set of parameters also provided flexibility in tool depth/orientation angle relative to the bone without sacrificing optimal process outcomes.","abstract_has_math":false,"creators":["Kusins, Jonathan"],"institution":"The University of Western Ontario","degree_name":"M Eng Sci","degree_level":null,"degree_discipline":"Mechanical and Materials Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Louis Ferreira","Remus Tutunea-Fatan"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-08-20","date_published":"2015-08-20","updated_at":"2026-07-27T21:55:54Z","subjects":["bone burring","bone resurfacing","bone removal parameters","experimental apparatus","superficial temperature","cutting forces"],"languages":["en_ca"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14721/36064","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Louis Ferreira","Remus Tutunea-Fatan"]},{"key":"dc:creator","label":"Author","values":["Kusins, Jonathan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-07-10T20:45:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-07-10T20:45:32Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-08-20"]},{"key":"dc:publisher","label":"Institution","values":["The University of Western Ontario"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Materials Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M Eng Sci"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["bone burring","bone resurfacing","bone removal parameters","experimental apparatus","superficial temperature","cutting forces"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_ca"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14721/36064"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The thesis cover page in the PDF document includes references to Western University’s previous institutional repository platform, known as Scholarship@Western, and links to that platform (beginning with ir.lib.uwo.ca). In citing or referring to this thesis, use the DOI or handle from this page instead. Sample citation: Author name, \"Thesis title.\" (Year). Western University Open Repository. https://doi.org/10.71858/123456."]},{"key":"dc:description.abstract","label":"Abstract","values":["The experimental quantification of the bone removal characteristics associated with bone burring represents a desirable outcome mainly for the selection of optimal parameters. An experimental apparatus was developed that allowed for concurrent measurement of three outputs associated with the bone removal process (cutting force, vibration, and temperature) as a function of various burring-specific parameters. Initial process trends were established on a uniform sawbone analog through use of a fully balanced multivariate statistical analysis. A smaller set of optimal and suboptimal parameters were further validated using a porcine femur. From the parameters tested, an optimal tool configuration, to avoid high temperature and high vibration, was found to be a 6 mm sphere burr at a rotational speed of 15,000 rpm, feed rate of 2 mm/s and a path overlap of 50%. This set of parameters also provided flexibility in tool depth/orientation angle relative to the bone without sacrificing optimal process outcomes."]},{"key":"dc:title","label":"Title","values":["Experimental Analysis of Parameters Influencing the Bone Burring Process"]}]}],"canonical_facts":{"dc:contributor.advisor":["Louis Ferreira","Remus Tutunea-Fatan"],"dc:creator":["Kusins, Jonathan"],"dc:date.accessioned":["2025-07-10T20:45:32Z"],"dc:date.available":["2025-07-10T20:45:32Z"],"dc:date.issued":["2015-08-20"],"dc:description":["The thesis cover page in the PDF document includes references to Western University’s previous institutional repository platform, known as Scholarship@Western, and links to that platform (beginning with ir.lib.uwo.ca). In citing or referring to this thesis, use the DOI or handle from this page instead. Sample citation: Author name, \"Thesis title.\" (Year). Western University Open Repository. https://doi.org/10.71858/123456."],"dc:description.abstract":["The experimental quantification of the bone removal characteristics associated with bone burring represents a desirable outcome mainly for the selection of optimal parameters. An experimental apparatus was developed that allowed for concurrent measurement of three outputs associated with the bone removal process (cutting force, vibration, and temperature) as a function of various burring-specific parameters. Initial process trends were established on a uniform sawbone analog through use of a fully balanced multivariate statistical analysis. A smaller set of optimal and suboptimal parameters were further validated using a porcine femur. From the parameters tested, an optimal tool configuration, to avoid high temperature and high vibration, was found to be a 6 mm sphere burr at a rotational speed of 15,000 rpm, feed rate of 2 mm/s and a path overlap of 50%. This set of parameters also provided flexibility in tool depth/orientation angle relative to the bone without sacrificing optimal process outcomes."],"dc:identifier.uri":["https://hdl.handle.net/20.500.14721/36064"],"dc:language.iso":["en_ca"],"dc:publisher":["The University of Western Ontario"],"dc:subject":["bone burring","bone resurfacing","bone removal parameters","experimental apparatus","superficial temperature","cutting forces"],"dc:title":["Experimental Analysis of Parameters Influencing the Bone Burring Process"],"dc:type":["thesis"],"thesis:degree_discipline":["Mechanical and Materials Engineering"],"thesis:degree_name":["M Eng Sci"]},"updated_at":"2026-07-27T21:55:54Z"}