{"id":{"repo_id":"uwo","oai_identifier":"oai:uwo.scholaris.ca:20.500.14721/35673"},"canonical_url":"https://search.dev.ndltd.org/etd/uwo/oai:uwo.scholaris.ca:20.500.14721/35673","repository":{"repo_id":"uwo","name":"Western University","base_url":"https://uwo.scholaris.ca/server/oai/request"},"display":{"title":"Osteoarthritis Induced Glenoid Morphology and Bone Quality: An Evaluation of Augmented Glenoid Components","abstract":"Osteoarthritis of the glenoid results in regional bone density variations and bone loss that may compromise early component fixation and support. The two common morphologies, symmetric and asymmetric erosion, were characterized by bone density and morphology, and assessed on the basis of bone removal and bone quality in the context of augmented glenoid components. The bone strain field was also compared when different augmented glenoid components underwent simulated joint loading using finite element analysis. Asymmetrically eroded glenoids were found to have denser bone (p","abstract_html":"Osteoarthritis of the glenoid results in regional bone density variations and bone loss that may compromise early component fixation and support. The two common morphologies, symmetric and asymmetric erosion, were characterized by bone density and morphology, and assessed on the basis of bone removal and bone quality in the context of augmented glenoid components. The bone strain field was also compared when different augmented glenoid components underwent simulated joint loading using finite element analysis. Asymmetrically eroded glenoids were found to have denser bone (p","abstract_has_math":false,"creators":["Knowles, Nikolas K"],"institution":"The University of Western Ontario","degree_name":"M Eng Sci","degree_level":null,"degree_discipline":"Mechanical and Materials Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Louis M. Ferreira"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-04-15","date_published":"2015-04-15","updated_at":"2026-07-27T21:56:11Z","subjects":["Glenoid morphology","osteoarthritis","glenoid implant fixation","finite element analysis","bone density"],"languages":["en_ca"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14721/35673","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Louis M. Ferreira"]},{"key":"dc:creator","label":"Author","values":["Knowles, Nikolas K"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-07-10T20:40:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-07-10T20:40:26Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-04-15"]},{"key":"dc:publisher","label":"Institution","values":["The University of Western Ontario"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Materials Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M Eng Sci"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Glenoid morphology","osteoarthritis","glenoid implant fixation","finite element analysis","bone density"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_ca"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14721/35673"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The thesis cover page in the PDF document includes references to Western University’s previous institutional repository platform, known as Scholarship@Western, and links to that platform (beginning with ir.lib.uwo.ca). In citing or referring to this thesis, use the DOI or handle from this page instead. Sample citation: Author name, \"Thesis title.\" (Year). Western University Open Repository. https://doi.org/10.71858/123456."]},{"key":"dc:description.abstract","label":"Abstract","values":["Osteoarthritis of the glenoid results in regional bone density variations and bone loss that may compromise early component fixation and support. The two common morphologies, symmetric and asymmetric erosion, were characterized by bone density and morphology, and assessed on the basis of bone removal and bone quality in the context of augmented glenoid components. The bone strain field was also compared when different augmented glenoid components underwent simulated joint loading using finite element analysis. Asymmetrically eroded glenoids were found to have denser bone (p"]},{"key":"dc:title","label":"Title","values":["Osteoarthritis Induced Glenoid Morphology and Bone Quality: An Evaluation of Augmented Glenoid Components"]}]}],"canonical_facts":{"dc:contributor.advisor":["Louis M. Ferreira"],"dc:creator":["Knowles, Nikolas K"],"dc:date.accessioned":["2025-07-10T20:40:26Z"],"dc:date.available":["2025-07-10T20:40:26Z"],"dc:date.issued":["2015-04-15"],"dc:description":["The thesis cover page in the PDF document includes references to Western University’s previous institutional repository platform, known as Scholarship@Western, and links to that platform (beginning with ir.lib.uwo.ca). In citing or referring to this thesis, use the DOI or handle from this page instead. Sample citation: Author name, \"Thesis title.\" (Year). Western University Open Repository. https://doi.org/10.71858/123456."],"dc:description.abstract":["Osteoarthritis of the glenoid results in regional bone density variations and bone loss that may compromise early component fixation and support. The two common morphologies, symmetric and asymmetric erosion, were characterized by bone density and morphology, and assessed on the basis of bone removal and bone quality in the context of augmented glenoid components. The bone strain field was also compared when different augmented glenoid components underwent simulated joint loading using finite element analysis. Asymmetrically eroded glenoids were found to have denser bone (p"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14721/35673"],"dc:language.iso":["en_ca"],"dc:publisher":["The University of Western Ontario"],"dc:subject":["Glenoid morphology","osteoarthritis","glenoid implant fixation","finite element analysis","bone density"],"dc:title":["Osteoarthritis Induced Glenoid Morphology and Bone Quality: An Evaluation of Augmented Glenoid Components"],"dc:type":["thesis"],"thesis:degree_discipline":["Mechanical and Materials Engineering"],"thesis:degree_name":["M Eng Sci"]},"updated_at":"2026-07-27T21:56:11Z"}