{"id":{"repo_id":"uwo","oai_identifier":"oai:uwo.scholaris.ca:20.500.14721/33001"},"canonical_url":"https://search.dev.ndltd.org/etd/uwo/oai:uwo.scholaris.ca:20.500.14721/33001","repository":{"repo_id":"uwo","name":"Western University","base_url":"https://uwo.scholaris.ca/server/oai/request"},"display":{"title":"Development and Validation of Mechatronic Systems for Image-Guided Needle Interventions and Point-of-Care Breast Cancer Screening with Ultrasound (2D and 3D) and Positron Emission Mammography","abstract":"The successful intervention of breast cancer relies on effective early detection and definitive diagnosis. While conventional screening mammography has substantially reduced breast cancer-related mortalities, substantial challenges persist in women with dense breasts. Additionally, complex interrelated risk factors and healthcare disparities contribute to breast cancer-related inequities, which restrict accessibility, impose cost constraints, and reduce inclusivity to high-quality healthcare. These limitations predominantly stem from the inadequate sensitivity and clinical utility of currently available approaches in increased-risk populations, including those with dense breasts, underserved and vulnerable populations. This PhD dissertation aims to describe the development and validation of alternative, cost-effective, robust, and high-resolution systems for point-of-care (POC) breast cancer screening and image-guided needle interventions. Specifically, 2D and 3D ultrasound (US) and positron emission mammography (PEM) were employed to improve detection, independent of breast density, in conjunction with mechatronic and automated approaches for accurate image acquisition and precise interventional workflow. First, a mechatronic guidance system for US-guided biopsy under high-resolution PEM localization was developed to improve spatial sampling of early-stage breast cancers. Validation and phantom studies showed accurate needle positioning and 3D spatial sampling under simulated PEM localization. Subsequently, a whole-breast spatially-tracked 3DUS system for point-of-care screening was developed, optimized, and validated within a clinically-relevant workspace and healthy volunteer studies. To improve robust image acquisition and adaptability to diverse patient populations, an alternative, cost-effective, portable, and patient-dedicated 3D automated breast (AB) US system for point-of-care screening was developed. Validation showed accurate geometric reconstruction, feasible clinical workflow, and proof-of-concept utility across healthy volunteers and acquisition conditions. Lastly, an orthogonal acquisition and 3D complementary breast (CB) US generation approach were described and experimentally validated to improve spatial resolution uniformity by recovering poor out-of-plane resolution. These systems developed and described throughout this dissertation show promise as alternative, cost-effective, robust, and high-resolution approaches for improving early detection and definitive diagnosis. Consequently, these contributions may advance breast cancer-related equities and improve outcomes in increased-risk populations and limited-resource settings.","abstract_html":"The successful intervention of breast cancer relies on effective early detection and definitive diagnosis. While conventional screening mammography has substantially reduced breast cancer-related mortalities, substantial challenges persist in women with dense breasts. Additionally, complex interrelated risk factors and healthcare disparities contribute to breast cancer-related inequities, which restrict accessibility, impose cost constraints, and reduce inclusivity to high-quality healthcare. These limitations predominantly stem from the inadequate sensitivity and clinical utility of currently available approaches in increased-risk populations, including those with dense breasts, underserved and vulnerable populations. This PhD dissertation aims to describe the development and validation of alternative, cost-effective, robust, and high-resolution systems for point-of-care (POC) breast cancer screening and image-guided needle interventions. Specifically, 2D and 3D ultrasound (US) and positron emission mammography (PEM) were employed to improve detection, independent of breast density, in conjunction with mechatronic and automated approaches for accurate image acquisition and precise interventional workflow. First, a mechatronic guidance system for US-guided biopsy under high-resolution PEM localization was developed to improve spatial sampling of early-stage breast cancers. Validation and phantom studies showed accurate needle positioning and 3D spatial sampling under simulated PEM localization. Subsequently, a whole-breast spatially-tracked 3DUS system for point-of-care screening was developed, optimized, and validated within a clinically-relevant workspace and healthy volunteer studies. To improve robust image acquisition and adaptability to diverse patient populations, an alternative, cost-effective, portable, and patient-dedicated 3D automated breast (AB) US system for point-of-care screening was developed. Validation showed accurate geometric reconstruction, feasible clinical workflow, and proof-of-concept utility across healthy volunteers and acquisition conditions. Lastly, an orthogonal acquisition and 3D complementary breast (CB) US generation approach were described and experimentally validated to improve spatial resolution uniformity by recovering poor out-of-plane resolution. These systems developed and described throughout this dissertation show promise as alternative, cost-effective, robust, and high-resolution approaches for improving early detection and definitive diagnosis. Consequently, these contributions may advance breast cancer-related equities and improve outcomes in increased-risk populations and limited-resource settings.","abstract_has_math":false,"creators":["Park, Claire KS"],"institution":"The University of Western Ontario","degree_name":"Ph D","degree_level":null,"degree_discipline":"Medical Biophysics","degree_department":null,"school":null,"contributors":[],"advisors":["Fenster, Aaron"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-05-30","date_published":"2023-05-30","updated_at":"2026-07-27T21:55:59Z","subjects":["three-dimensional ultrasound","automated breast ultrasound","breast cancer screening","point-of-care ultrasound","system development and validation","image registration"],"languages":["en_ca"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14721/33001","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fenster, Aaron"]},{"key":"dc:creator","label":"Author","values":["Park, Claire KS"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-07-10T19:40:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-07-10T19:40:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-05-30"]},{"key":"dc:publisher","label":"Institution","values":["The University of Western Ontario"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Medical Biophysics"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph D"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["three-dimensional ultrasound","automated breast ultrasound","breast cancer screening","point-of-care ultrasound","system development and validation","image registration"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_ca"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14721/33001"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Collaborative Specialization: Molecular Imaging","The thesis cover page in the PDF document includes references to Western University’s previous institutional repository platform, known as Scholarship@Western, and links to that platform (beginning with ir.lib.uwo.ca). In citing or referring to this thesis, use the DOI or handle from this page instead. Sample citation: Author name, \"Thesis title.\" (Year). Western University Open Repository. https://doi.org/10.71858/123456."]},{"key":"dc:description.abstract","label":"Abstract","values":["The successful intervention of breast cancer relies on effective early detection and definitive diagnosis. While conventional screening mammography has substantially reduced breast cancer-related mortalities, substantial challenges persist in women with dense breasts. Additionally, complex interrelated risk factors and healthcare disparities contribute to breast cancer-related inequities, which restrict accessibility, impose cost constraints, and reduce inclusivity to high-quality healthcare. These limitations predominantly stem from the inadequate sensitivity and clinical utility of currently available approaches in increased-risk populations, including those with dense breasts, underserved and vulnerable populations. This PhD dissertation aims to describe the development and validation of alternative, cost-effective, robust, and high-resolution systems for point-of-care (POC) breast cancer screening and image-guided needle interventions. Specifically, 2D and 3D ultrasound (US) and positron emission mammography (PEM) were employed to improve detection, independent of breast density, in conjunction with mechatronic and automated approaches for accurate image acquisition and precise interventional workflow. First, a mechatronic guidance system for US-guided biopsy under high-resolution PEM localization was developed to improve spatial sampling of early-stage breast cancers. Validation and phantom studies showed accurate needle positioning and 3D spatial sampling under simulated PEM localization. Subsequently, a whole-breast spatially-tracked 3DUS system for point-of-care screening was developed, optimized, and validated within a clinically-relevant workspace and healthy volunteer studies. To improve robust image acquisition and adaptability to diverse patient populations, an alternative, cost-effective, portable, and patient-dedicated 3D automated breast (AB) US system for point-of-care screening was developed. Validation showed accurate geometric reconstruction, feasible clinical workflow, and proof-of-concept utility across healthy volunteers and acquisition conditions. Lastly, an orthogonal acquisition and 3D complementary breast (CB) US generation approach were described and experimentally validated to improve spatial resolution uniformity by recovering poor out-of-plane resolution. These systems developed and described throughout this dissertation show promise as alternative, cost-effective, robust, and high-resolution approaches for improving early detection and definitive diagnosis. Consequently, these contributions may advance breast cancer-related equities and improve outcomes in increased-risk populations and limited-resource settings."]},{"key":"dc:title","label":"Title","values":["Development and Validation of Mechatronic Systems for Image-Guided Needle Interventions and Point-of-Care Breast Cancer Screening with Ultrasound (2D and 3D) and Positron Emission Mammography"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fenster, Aaron"],"dc:creator":["Park, Claire KS"],"dc:date.accessioned":["2025-07-10T19:40:46Z"],"dc:date.available":["2025-07-10T19:40:46Z"],"dc:date.issued":["2023-05-30"],"dc:description":["Collaborative Specialization: Molecular Imaging","The thesis cover page in the PDF document includes references to Western University’s previous institutional repository platform, known as Scholarship@Western, and links to that platform (beginning with ir.lib.uwo.ca). In citing or referring to this thesis, use the DOI or handle from this page instead. Sample citation: Author name, \"Thesis title.\" (Year). Western University Open Repository. https://doi.org/10.71858/123456."],"dc:description.abstract":["The successful intervention of breast cancer relies on effective early detection and definitive diagnosis. While conventional screening mammography has substantially reduced breast cancer-related mortalities, substantial challenges persist in women with dense breasts. Additionally, complex interrelated risk factors and healthcare disparities contribute to breast cancer-related inequities, which restrict accessibility, impose cost constraints, and reduce inclusivity to high-quality healthcare. These limitations predominantly stem from the inadequate sensitivity and clinical utility of currently available approaches in increased-risk populations, including those with dense breasts, underserved and vulnerable populations. This PhD dissertation aims to describe the development and validation of alternative, cost-effective, robust, and high-resolution systems for point-of-care (POC) breast cancer screening and image-guided needle interventions. Specifically, 2D and 3D ultrasound (US) and positron emission mammography (PEM) were employed to improve detection, independent of breast density, in conjunction with mechatronic and automated approaches for accurate image acquisition and precise interventional workflow. First, a mechatronic guidance system for US-guided biopsy under high-resolution PEM localization was developed to improve spatial sampling of early-stage breast cancers. Validation and phantom studies showed accurate needle positioning and 3D spatial sampling under simulated PEM localization. Subsequently, a whole-breast spatially-tracked 3DUS system for point-of-care screening was developed, optimized, and validated within a clinically-relevant workspace and healthy volunteer studies. To improve robust image acquisition and adaptability to diverse patient populations, an alternative, cost-effective, portable, and patient-dedicated 3D automated breast (AB) US system for point-of-care screening was developed. Validation showed accurate geometric reconstruction, feasible clinical workflow, and proof-of-concept utility across healthy volunteers and acquisition conditions. Lastly, an orthogonal acquisition and 3D complementary breast (CB) US generation approach were described and experimentally validated to improve spatial resolution uniformity by recovering poor out-of-plane resolution. These systems developed and described throughout this dissertation show promise as alternative, cost-effective, robust, and high-resolution approaches for improving early detection and definitive diagnosis. Consequently, these contributions may advance breast cancer-related equities and improve outcomes in increased-risk populations and limited-resource settings."],"dc:identifier.uri":["https://hdl.handle.net/20.500.14721/33001"],"dc:language.iso":["en_ca"],"dc:publisher":["The University of Western Ontario"],"dc:subject":["three-dimensional ultrasound","automated breast ultrasound","breast cancer screening","point-of-care ultrasound","system development and validation","image registration"],"dc:title":["Development and Validation of Mechatronic Systems for Image-Guided Needle Interventions and Point-of-Care Breast Cancer Screening with Ultrasound (2D and 3D) and Positron Emission Mammography"],"dc:type":["thesis"],"thesis:degree_discipline":["Medical Biophysics"],"thesis:degree_name":["Ph D"]},"updated_at":"2026-07-27T21:55:59Z"}