{"id":{"repo_id":"uwo","oai_identifier":"oai:uwo.scholaris.ca:20.500.14721/32467"},"canonical_url":"https://search.dev.ndltd.org/etd/uwo/oai:uwo.scholaris.ca:20.500.14721/32467","repository":{"repo_id":"uwo","name":"Western University","base_url":"https://uwo.scholaris.ca/server/oai/request"},"display":{"title":"Modelling and Evaluation of Piezoelectric Actuators for Wearable Neck Rehabilitation Devices","abstract":"Neck pain is the most common neck musculoskeletal disorder, and the fourth leading cause of healthy years lost due to disability in the world. Due to the need of hands-on physical therapy and Canada’s aging population, access to treatment will become highly constrained. Wearable devices that allow at-home rehabilitation address this future limitation. However, few have emerged from the laboratory setting because they are limited by the use of conventional actuators. An overlooked type of actuation technology is that of piezoelectric actuators, more specifically, travelling wave ultrasonic motors (TWUM). In this work, a clear procedure that outlines how the required parameters within the hybrid TWUM model can be identified, as well as an assessment of the use of TWUMs within wearable devices for the neck, is presented. The procedure includes custom testing setups that were designed to identify the stator motion parameters, and the Coulomb coefficient of friction. The accuracy of the determined parameters were confirmed when the angular velocity of the hybrid model at different duty cycles was compared to the real TWUM being modelled, producing a coefficient of determination of 0.974. The model was then used to create a position control system that controlled the joints of a virtual robotic manipulator that modelled the neck. The manipulator exhibited a maximum absolute mean error of only 0.0289 m when simulating the required trajectories of range of motion exercises. This performance, in addition to the exemplary traits TWUMs express, demonstrate their potential to advance the field of wearable mechatronic devices.","abstract_html":"Neck pain is the most common neck musculoskeletal disorder, and the fourth leading cause of healthy years lost due to disability in the world. Due to the need of hands-on physical therapy and Canada’s aging population, access to treatment will become highly constrained. Wearable devices that allow at-home rehabilitation address this future limitation. However, few have emerged from the laboratory setting because they are limited by the use of conventional actuators. An overlooked type of actuation technology is that of piezoelectric actuators, more specifically, travelling wave ultrasonic motors (TWUM). In this work, a clear procedure that outlines how the required parameters within the hybrid TWUM model can be identified, as well as an assessment of the use of TWUMs within wearable devices for the neck, is presented. The procedure includes custom testing setups that were designed to identify the stator motion parameters, and the Coulomb coefficient of friction. The accuracy of the determined parameters were confirmed when the angular velocity of the hybrid model at different duty cycles was compared to the real TWUM being modelled, producing a coefficient of determination of 0.974. The model was then used to create a position control system that controlled the joints of a virtual robotic manipulator that modelled the neck. The manipulator exhibited a maximum absolute mean error of only 0.0289 m when simulating the required trajectories of range of motion exercises. This performance, in addition to the exemplary traits TWUMs express, demonstrate their potential to advance the field of wearable mechatronic devices.","abstract_has_math":false,"creators":["Tracey, Shaemus D"],"institution":"The University of Western Ontario","degree_name":"M Eng Sci","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Trejos, Ana Luisa"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-09-16","date_published":"2022-09-16","updated_at":"2026-07-27T21:55:59Z","subjects":["Piezoelectric","Travelling Wave Ultrasonic Motor","Wearable Mechatronic Devices"],"languages":["en_ca"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14721/32467","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Trejos, Ana Luisa"]},{"key":"dc:creator","label":"Author","values":["Tracey, Shaemus D"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-07-10T19:31:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-07-10T19:31:03Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-09-16"]},{"key":"dc:publisher","label":"Institution","values":["The University of Western Ontario"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M Eng Sci"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Piezoelectric","Travelling Wave Ultrasonic Motor","Wearable Mechatronic Devices"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_ca"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14721/32467"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Collaborative Specialization: Musculoskeletal Health Research","The thesis cover page in the PDF document includes references to Western University’s previous institutional repository platform, known as Scholarship@Western, and links to that platform (beginning with ir.lib.uwo.ca). In citing or referring to this thesis, use the DOI or handle from this page instead. Sample citation: Author name, \"Thesis title.\" (Year). Western University Open Repository. https://doi.org/10.71858/123456."]},{"key":"dc:description.abstract","label":"Abstract","values":["Neck pain is the most common neck musculoskeletal disorder, and the fourth leading cause of healthy years lost due to disability in the world. Due to the need of hands-on physical therapy and Canada’s aging population, access to treatment will become highly constrained. Wearable devices that allow at-home rehabilitation address this future limitation. However, few have emerged from the laboratory setting because they are limited by the use of conventional actuators. An overlooked type of actuation technology is that of piezoelectric actuators, more specifically, travelling wave ultrasonic motors (TWUM). In this work, a clear procedure that outlines how the required parameters within the hybrid TWUM model can be identified, as well as an assessment of the use of TWUMs within wearable devices for the neck, is presented. The procedure includes custom testing setups that were designed to identify the stator motion parameters, and the Coulomb coefficient of friction. The accuracy of the determined parameters were confirmed when the angular velocity of the hybrid model at different duty cycles was compared to the real TWUM being modelled, producing a coefficient of determination of 0.974. The model was then used to create a position control system that controlled the joints of a virtual robotic manipulator that modelled the neck. The manipulator exhibited a maximum absolute mean error of only 0.0289 m when simulating the required trajectories of range of motion exercises. This performance, in addition to the exemplary traits TWUMs express, demonstrate their potential to advance the field of wearable mechatronic devices."]},{"key":"dc:title","label":"Title","values":["Modelling and Evaluation of Piezoelectric Actuators for Wearable Neck Rehabilitation Devices"]}]}],"canonical_facts":{"dc:contributor.advisor":["Trejos, Ana Luisa"],"dc:creator":["Tracey, Shaemus D"],"dc:date.accessioned":["2025-07-10T19:31:03Z"],"dc:date.available":["2025-07-10T19:31:03Z"],"dc:date.issued":["2022-09-16"],"dc:description":["Collaborative Specialization: Musculoskeletal Health Research","The thesis cover page in the PDF document includes references to Western University’s previous institutional repository platform, known as Scholarship@Western, and links to that platform (beginning with ir.lib.uwo.ca). In citing or referring to this thesis, use the DOI or handle from this page instead. Sample citation: Author name, \"Thesis title.\" (Year). Western University Open Repository. https://doi.org/10.71858/123456."],"dc:description.abstract":["Neck pain is the most common neck musculoskeletal disorder, and the fourth leading cause of healthy years lost due to disability in the world. Due to the need of hands-on physical therapy and Canada’s aging population, access to treatment will become highly constrained. Wearable devices that allow at-home rehabilitation address this future limitation. However, few have emerged from the laboratory setting because they are limited by the use of conventional actuators. An overlooked type of actuation technology is that of piezoelectric actuators, more specifically, travelling wave ultrasonic motors (TWUM). In this work, a clear procedure that outlines how the required parameters within the hybrid TWUM model can be identified, as well as an assessment of the use of TWUMs within wearable devices for the neck, is presented. The procedure includes custom testing setups that were designed to identify the stator motion parameters, and the Coulomb coefficient of friction. The accuracy of the determined parameters were confirmed when the angular velocity of the hybrid model at different duty cycles was compared to the real TWUM being modelled, producing a coefficient of determination of 0.974. The model was then used to create a position control system that controlled the joints of a virtual robotic manipulator that modelled the neck. The manipulator exhibited a maximum absolute mean error of only 0.0289 m when simulating the required trajectories of range of motion exercises. This performance, in addition to the exemplary traits TWUMs express, demonstrate their potential to advance the field of wearable mechatronic devices."],"dc:identifier.uri":["https://hdl.handle.net/20.500.14721/32467"],"dc:language.iso":["en_ca"],"dc:publisher":["The University of Western Ontario"],"dc:subject":["Piezoelectric","Travelling Wave Ultrasonic Motor","Wearable Mechatronic Devices"],"dc:title":["Modelling and Evaluation of Piezoelectric Actuators for Wearable Neck Rehabilitation Devices"],"dc:type":["thesis"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["M Eng Sci"]},"updated_at":"2026-07-27T21:55:59Z"}