Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy

Abstract

dc:description.abstract

Kilovoltage cone-beam computed tomography (kV CBCT) has important applications in image guided radiation therapy (IGRT). In its current state, CBCT is suboptimal for these applications due to its considerable radiation dose, poor soft-tissue contrast and inaccurate Hounsfield Units as a result of in-patient scatter. The specific aims of this dissertation research are to: 1) reduce noise associated with the low-dose CBCT scans acquired with low tube current/time (mAs) protocols by the application of innovative software; and 2) develop a moving blocker system for kV scatter correction in CBCT scans acquired both with and without concurrent megavoltage radiation therapy. The noise reduction of low-dose CBCT was achieved through statistical image reconstruction or image restoration in the CBCT projections. Performance of three statistical iterative image reconstruction algorithms was compared through the noise-resolution-tradeoff analysis. Results of the comparison study suggested that different algorithms were favored in different imaging tasks and conditions. A CBCT projection smoothing algorithm that incorporates prior CBCT imaging data was proposed in this dissertation as an alternate way to improve image quality of the low-dose CBCT. For this approach, the Karhunen-Loève (KL) transform was used to account for the correlation among consecutively acquired CBCT projections. Results from phantom-based studies showed that the KL domain penalized weighted least-square (PWLS) restoration were superior to PWLS smoothing in the projection domain in overall image quality improvement of low-dose CBCT. A moving blocker system was implemented on a LINAC on-board imaging system. Experimental evaluation of the system demonstrated that the moving-blocker based scatter correction strategy in kV CBCT is reliable and practical. Finally, the moving-blocker scatter correction strategy was extended for simultaneous MV-kV scatter correction of kV CBCT acquired during rotational radiation therapy. In both kV-only scatter correction and MV-kV scatter correction, high quality CBCT images were reconstructed following the moving-blocker scatter correction. CBCT image sets acquired with these methods were found to contain accurate CT numbers and minimal shading artifacts and could therefore be used for dose calculation purposes in adaptive radiation therapy.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Radiological Sciences
Grantor
UT Southwestern Medical Center
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ouyang, Luo
Advisor dc:contributor.advisor
  • Medin, Paul
Committee members dc:contributor.committeemember
  • Wang, Jing
  • Jiang, Steve B.
  • Pompos, Arnold
  • Sun, Xiankai

Subjects

dc:subject × 3

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Identifier
952355716

Chain of custody

source
Harvested from
University of Texas Southwestern Medical Center
Base URL
utswmed-ir.tdl.org/server/oai/request
Last updated
2026-08-21
Source record
OAI-PMH GetRecord
citation

Ouyang, Luo. Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy. Doctoral thesis, UT Southwestern Medical Center, 2014. https://hdl.handle.net/2152.5/3321