Back to results

University of Texas Health Science Center at Houston

Novel Simulation to Avoid Bias In Measurement of Hyperpolarized Pyruvate: Demonstrated In Phantom and In Vivo

Abstract

dc:description.abstract

<p>Dynamic nuclear polarization creates a transient hyperpolarized nuclear state that can dramatically increase the signal detected by magnetic resonance imaging. This signal increase allows real-time spectroscopic imaging of specific metabolites <em>in vivo </em>by magnetic resonance. Real-time imaging of both the spatial and chemical fate of hyperpolarized metabolites is showing great promise to meaningfully benefit clinical care of cancer patients. Imaging of hyperpolarized agents will have a larger clinical impact if it can function as a quantitative modality upon which clinical decisions can be made. However, quantitative measurement of hyperpolarized agents is currently difficult due to the restrictions imposed by the transient hyperpolarized state and the complexity inherent in biological systems. As more advanced imaging and measurement techniques are developed for imaging hyperpolarized substrates, it is critical to characterize their effect on any relevant quantitative measure. To assist in accurate quantitative measurement of hyperpolarized agents, an infrastructure where acquisition strategies can be developed, compared, optimized and validated was critically need. A novel simulation architecture was developed that combines classical chemical kinetics with the basic physics of nuclear magnetic resonance and couples them to multiple perfusion models. Simulation results showed that changes in the acquisition strategy used will affect the resulting quantification of chemical exchange rates and suggested that any bias that is imposed by the acquisition strategy can be avoided by using optimized pulse sequences. To validate these predictions, a phantom system was developed that allows controllable chemical conversion of hyperpolarized pyruvate into lactate with a variability less than 20%. Using this phantom system, studies showed that poorly optimized pulse sequences significantly reduced the measured value of the chemical exchange rates, whereas optimized pulse sequences showed no significant difference in chemical exchange measurements. In order to test simulation predictions for a perfused system, an animal cohort with orthotropic anaplastic thyroid cancer was scanned with multiple sequences. Again, optimized sequences showed no significant difference in measured exchange rates while poorly designed sequences significantly underestimated the exchange rates, which is consistent with the simulation results. These validation studies suggest that this simulation architecture will be a powerful tool for developing and optimizing acquisition and quantization methods for hyperpolarized magnetic resonance imaging.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (PhD)
Level thesis:degree_level
Dissertation (PhD)
Year dc:date.available
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Walker, Christopher M
Contributors dc:contributor
  • James A. Bankson
  • John Hazle
  • Dawid Schellingerhout

Subjects

dc:subject × 7

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:digitalcommons.library.tmc.edu:utgsbs_dissertations-1756

Chain of custody

source
Harvested from
University of Texas Health Science Center at Houston
Base URL
digitalcommons.library.tmc.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Walker, Christopher M. Novel Simulation to Avoid Bias In Measurement of Hyperpolarized Pyruvate: Demonstrated In Phantom and In Vivo. Dissertation (PhD) thesis, 2016. https://digitalcommons.library.tmc.edu/utgsbs_dissertations/712