Characterization of The New Xoft Axxent Electronic Brachytherapy Source Using Presage(Tm)

Abstract

dc:description.abstract

<p>With continuing advances in the burgeoning field of electronic brachytherapy, an accurate method of 3D dosimetry is needed to ensure understanding of dose distributions, which can improve patient care. The aim of this study was to characterize the Xoft Axxent electronic brachytherapy source using PRESAGE<sup>TM</sup> dosimeters in order to obtain independent confirmation of TG-43U1 dosimetry values, as well as to further add to the literature of both Xoft and PRESAGE.</p> <p>PRESAGE is a polyurethane-based solid 3D dosimeter doped with a radiochromic leuco dye which produces a linear change in optical density when exposed to radiation. This optical density change is imaged using an optical-CT scanner and reconstructed for analysis using MATLAB software. A Xoft source with a measured air kerma strength of 126095 U was used in this experiment to irradiate 8 PRESAGE dosimeters to 15 Gy at 1 cm in order to evaluate the dose rates from r=1 cm to r=5 cm. The dosimetric parameters were calculated and compared to the Rivard et al. (<a title="Rivard, 2006 #75">1</a>) parameters.</p> <p>In general, the measured results closer to the source more closely matched the comparison data than those values measured further from the source. The radial dose function was within 6% of the expected values, and the anisotropy function, ignoring the extreme outlier at each radius, was within 35% of the expected values. An incorrect shutter value was used when imaging the dosimeters so that the post-irradiation scans were repeated 2 months after the irradiation, allowing time for the dosimeter to darken as it aged, which increased background noise, and time for the dose signal to fade, thereby bringing the dose signal closer to the background noise. The experiment should be repeated to obtain more accurate results.</p>

Degree

thesis:*
Name thesis:degree_name
Masters of Science (MS)
Level thesis:degree_level
Thesis (MS)
Year dc:date.available
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Irwin, Jennifer Sierra
Contributors dc:contributor
  • Geoffrey Ibbott, Ph.D.
  • David Followill, Ph.D.
  • Kent Gifford, Ph.D.

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:digitalcommons.library.tmc.edu:utgsbs_dissertations-1542

Chain of custody

source
Harvested from
University of Texas Health Science Center at Houston
Base URL
digitalcommons.library.tmc.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Irwin, Jennifer Sierra. Characterization of The New Xoft Axxent Electronic Brachytherapy Source Using Presage(Tm). Thesis (MS) thesis, 2014. https://digitalcommons.library.tmc.edu/utgsbs_dissertations/503