Evaluation of Deformable Image Registration For Improved 4D Ct-Derived Ventilation For Image Guided Radiotherapy

Abstract

dc:description.abstract

<p>Recent treatment planning studies have demonstrated the use of physiologic images in radiation therapy treatment planning to identify regions for functional avoidance. This image-guided radiotherapy (IGRT) strategy may reduce the injury and/or functional loss following thoracic radiotherapy. 4D computed tomography (CT), developed for radiotherapy treatment planning, is a relatively new imaging technique that allows the acquisition of a time-varying sequence of 3D CT images of the patient's lungs through the respiratory cycle. Guerrero et al. developed a method to calculate ventilation imaging from 4D CT, which is potentially better suited and more broadly available for IGRT than the current standard imaging methods. The key to extracting function information from 4D CT is the construction of a volumetric deformation field that accurately tracks the motion of the patient's lungs during the respiratory cycle. The spatial accuracy of the displacement field directly impacts the ventilation images; higher spatial registration accuracy will result in less ventilation image artifacts and physiologic inaccuracies. Presently, a consistent methodology for spatial accuracy evaluation of the DIR transformation is lacking. Evaluation of the 4D CT-derived ventilation images will be performed to assess correlation with global measurements of lung ventilation, as well as regional correlation of the distribution of ventilation with the current clinical standard SPECT. This requires a novel framework for both the detailed assessment of an image registration algorithm's performance characteristics as well as quality assurance for spatial accuracy assessment in routine application. Finally, we hypothesize that hypo-ventilated regions, identified on 4D CT ventilation images, will correlate with hypo-perfused regions in lung cancer patients who have obstructive lesions. A prospective imaging trial of patients with locally advanced non-small-cell lung cancer will allow this hypothesis to be tested. These advances are intended to contribute to the validation and clinical implementation of CT-based ventilation imaging in prospective clinical trials, in which the impact of this imaging method on patient outcomes may be tested.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (PhD)
Level thesis:degree_level
Dissertation (PhD)
Year dc:date.available
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Castillo, Richard
Contributors dc:contributor
  • Thomas Guerrero, MD, PhD
  • Mary Martel, PhD
  • Tinsu Pan, PhD

Subjects

dc:subject × 9

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:digitalcommons.library.tmc.edu:utgsbs_dissertations-1215

Chain of custody

source
Harvested from
University of Texas Health Science Center at Houston
Base URL
digitalcommons.library.tmc.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Castillo, Richard. Evaluation of Deformable Image Registration For Improved 4D Ct-Derived Ventilation For Image Guided Radiotherapy. Dissertation (PhD) thesis, 2011. https://digitalcommons.library.tmc.edu/utgsbs_dissertations/188