Back to results

University of Texas Health Science Center at Houston

The Effect of Shoulder Variation On Imrt and Smartarc For Head and Neck Cancer

Abstract

dc:description.abstract

<p><strong>Purpose: </strong>First, to determine an average and maximum displacement of the shoulder relative to isocenter over the course of treatment. Second, to establish the dosimetric effect of shoulder displacements relative to correct isocenter alignment on the dose delivered to the target and the surrounding structures for head and neck cancer patients.</p> <p><strong>Method and Materials: </strong>The frequency of shoulder shifts of various magnitudes relative to isocenter was assessed for 4 patients using image registration software. The location of the center of the right and left humeral head relative to isocenter (usually C2) was found daily from CT on rails scans, and was compared to the location of the humeral heads relative to isocenter on the initial simulation CT. Three Baseline head and neck IMRT and SmartArc plans were generated in Pinnacle based on simulation CTs. The CT datasets (external contour and boney structures) were then modified to represent shifts of the shoulder (relative to isocenter) between 3 mm and 15 mm in the SI, AP, and LR directions. The initial plans were recalculated on the image sets with shifted shoulders.</p> <p><strong>Results:</strong> On average, shoulder variation was 2-5 mm in each direction, although displacements of over 1 cm in the inferior and posterior directions occurred. Shoulder shifts induced perturbations in the dose distribution, although generally only for large shifts. Most substantially, large, superior shifts resulted in coverage loss by the 95% isodose line for targets in the lower neck. Inferior shifts elevated the dose to the brachial plexus by 0.6-4.1 Gy. SmartArc plans showed similar loss of target coverage as IMRT plans.</p> <p><strong>Conclusions:</strong> The position of the shoulder can have an impact on target coverage and critical structure dose. Shoulder position may need to be considered for setup of head and neck patients depending on target location.</p>

Degree

thesis:*
Name thesis:degree_name
Masters of Science (MS)
Level thesis:degree_level
Thesis (MS)
Year dc:date.available
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Neubauer, Emily H
Contributors dc:contributor
  • Stephen F. Kry, PhD
  • David Followill, PhD
  • R. Allen White, PhD

Subjects

dc:subject × 8

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:digitalcommons.library.tmc.edu:utgsbs_dissertations-1190

Chain of custody

source
Harvested from
University of Texas Health Science Center at Houston
Base URL
digitalcommons.library.tmc.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Neubauer, Emily H. The Effect of Shoulder Variation On Imrt and Smartarc For Head and Neck Cancer. Thesis (MS) thesis, 2011. https://digitalcommons.library.tmc.edu/utgsbs_dissertations/163