Back to results

Universiti Tun Hussein Onn Malaysia

Reflectance spectroscopy system for real time and non-invasive detection of transcutaneous bilirubin level

Abstract

dc:description.abstract

Blood bilirubin level would be elevated when one's liver is unable to remove bilirubin sufficiently from the blood. The conventional methods used for monitoring and measuring the bilirubin level are time consuming, tedious and invasive in nature. This study aims to investigate the feasibility of using Modified Lambeti Beer (MLB) A model in the prediction of one's bilirubin concentration using a priori knowledge of the extinction coefficient of bilirubin and haemoglobin components in the wavelength range of 400 500 nm. This study verified validity of the predicted value using light attenuation data from TracePro for a single-layered skin model with varying bilirubin concentration. The results revealed some promising trends in estimated bilirubin concentration and considerably good accuracy with percent mean relative error in the predicted bilirubin concentration, Cbil(p) calculated as 59.9 %. This study performed contact and non-contact experiments for the demonstration works. A total number of 60 individuals of different health status, skin tone and gender have been recruited for the contact experiment. Meanwhile, six healthy subjects was recruited for the noncontact experiment, and measurement was performed at various selected skin sites. From the contact experiment, this work found a lower skin bilirubin level in renal disease subjects compared to healthy subjects. In addition, a lower bilirubin was observed for individuals with dark skin compared to fair skin, and a higher bilirubin level in male compared to their female counterparts. Based on the experiments performed on healthy subjects using non-contact experiment arrangement, this work found that palm site has the lowest in the predicted mean transcutaneous bilirubin concentration with highest consistency given by 0.44±0.4 g/1 as compared to other skin sites. This study concluded that the developed system and strategy may be used as an alternative means to assess one's skin bilirubin level.

Degree

thesis:*
Name dc:type.qualificationname
mphil
Level dc:type.qualificationlevel
masters
Grantor dc:publisher.institution
Universiti Tun Hussein Onn Malaysia
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ong, Pek Ek

Subjects

dc:subject × 1

Rights

Language dc:language
en

Chain of custody

source
Harvested from
Universiti Tun Hussein Onn Malaysia
Base URL
eprints.uthm.edu.my/cgi/oai2
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Ong, Pek Ek. Reflectance spectroscopy system for real time and non-invasive detection of transcutaneous bilirubin level. masters thesis, Universiti Tun Hussein Onn Malaysia, 2018.