Back to results

Universiti Tun Hussein Malaysia

Comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment

Abstract

dc:description.abstract

Indoor Air Quality (IAQ) is a part of Building Environment. Nowadays, the construction of new building took place over the world. Upon new building occupancy, a lot of indoors material was used without IAQ concern. This study has been conducted in a new constructed building of the National Institute of Occupational Safety and Health (NIOSH) Malaysia. The goal of the study is to monitor on the level of IAQ parameters including chemical and physical parameters within four consequent stages which are before furniture install, after furniture install and during one and three month occupancy. The indoor parameters have been measured consist of nine parameters including of Carbon Dioxide (CO2), Carbon Monoxide (CO), Total Volatile Organic Compounds (TVOC), Formaldehyde, Respirable Particulates (PM10), Ozone, Relative Humidity (RH), Temperature and Air Movement. The interaction between Malaysian and international standard was referred and utilized in collecting the data and analyzing of the findings. There was a significant correlation between the high values of RH, Formaldehyde and PM10 where (r 0.324, p <0.05), (r 0.344, p <0.05) and (r 0.319, p<0.05) with extension of phases of new building occupancy respectively. This study established significant different on Formaldehyde and Particulate Matter (PM10) concentration level as go along with the building occupancy. These finding indicated that furniture and fittings, indoor materials and human population has a potential sources of indoor air contaminants. It is recommended that the management should be aware to their indoor air status to protect the occupant from the risk of unwanted exposure especially during the early stage of building occupancy. Finally this research has fully supported the Malaysian need to formulate of future guideline on IAQ commissioning and maintenance of new building occupancy.

Degree

thesis:*
Name dc:type.qualificationname
mphil
Level dc:type.qualificationlevel
masters
Grantor dc:publisher.institution
Universiti Tun Hussein Malaysia
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Noraini, Nor Mohd Razif

Subjects

dc:subject × 1

Rights

Language dc:language
en

Chain of custody

source
Harvested from
Universiti Tun Hussein Onn Malaysia
Base URL
eprints.uthm.edu.my/cgi/oai2
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Noraini, Nor Mohd Razif. Comparative study of indoor air contaminants in different stages of new building occupancy: work environment assessment. masters thesis, Universiti Tun Hussein Malaysia, 2015.