{"id":{"repo_id":"uthm","oai_identifier":"oai:eprints.uthm.edu.my:1505"},"canonical_url":"https://search.dev.ndltd.org/etd/uthm/oai:eprints.uthm.edu.my:1505","repository":{"repo_id":"uthm","name":"Universiti Tun Hussein Onn Malaysia","base_url":"http://eprints.uthm.edu.my/cgi/oai2"},"display":{"title":"Fast transient simulation of pinceti surge arrester model on a transmission line using ATP Software","abstract":"Lightning is one of the main causes of overvoltage on power system. Over voltages problem at the transmission line can cause flashover voltage at the insulator string, power system disturbances and transformer failure. To prevent of insulator string and equipment of the power system from damaging effect by lightning overvoltage, metal oxide surge arrester is installed at overhead line in parallel with insulator string. Due to metal oxide surge arrester have dynamic behaviour, this arrester can be simulated using non-linear resistor. Therefore Pinceti model is proposed to simulate using Alternative Transient Program (ATP) software. Several procedures have been following to calculate Pinceti arrester model parameters so that compatible with 132kV overhead transmission line system. Tested result by simulation is compared with the manufacturer arrester datasheet to evaluate accuracy of Pinceti model before installed arrester at 132kV transmission line model. Pinceti model are installed at several locations on the transmission line model to evaluate the level of effectiveness and capabilities to reduce the level of overvoltage across insulator string and to ensure lightning overcurrent draws to ground totally.","abstract_html":"Lightning is one of the main causes of overvoltage on power system. Over voltages problem at the transmission line can cause flashover voltage at the insulator string, power system disturbances and transformer failure. To prevent of insulator string and equipment of the power system from damaging effect by lightning overvoltage, metal oxide surge arrester is installed at overhead line in parallel with insulator string. Due to metal oxide surge arrester have dynamic behaviour, this arrester can be simulated using non-linear resistor. Therefore Pinceti model is proposed to simulate using Alternative Transient Program (ATP) software. Several procedures have been following to calculate Pinceti arrester model parameters so that compatible with 132kV overhead transmission line system. Tested result by simulation is compared with the manufacturer arrester datasheet to evaluate accuracy of Pinceti model before installed arrester at 132kV transmission line model. Pinceti model are installed at several locations on the transmission line model to evaluate the level of effectiveness and capabilities to reduce the level of overvoltage across insulator string and to ensure lightning overcurrent draws to ground totally.","abstract_has_math":false,"creators":["Muhamad, Yusof"],"institution":"Universiti Tun Hussein Onn Malaysia","degree_name":"mphil","degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-01","date_published":"2015-01","updated_at":"2026-07-24T05:48:31Z","subjects":["TK3001-3521 Distribution or transmission of electric power"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Muhamad, Yusof"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-01"]},{"key":"dc:date.issued","label":"Date","values":["2015-01"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Faculty of Electrical and Electronics Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Universiti Tun Hussein Onn Malaysia"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://eprints.uthm.edu.my/1505/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["masters"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["mphil"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TK3001-3521 Distribution or transmission of electric power"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://eprints.uthm.edu.my/1505/1/YUSOF%20MUHAMAD%20COPYRIGHT%20DECLARATION.pdf","http://eprints.uthm.edu.my/1505/2/24p%20YUSOF%20MUHAMAD.pdf","http://eprints.uthm.edu.my/1505/3/YUSOF%20MUHAMAD%20WATERMARK.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Lightning is one of the main causes of overvoltage on power system. Over voltages problem at the transmission line can cause flashover voltage at the insulator string, power system disturbances and transformer failure. To prevent of insulator string and equipment of the power system from damaging effect by lightning overvoltage, metal oxide surge arrester is installed at overhead line in parallel with insulator string. Due to metal oxide surge arrester have dynamic behaviour, this arrester can be simulated using non-linear resistor. Therefore Pinceti model is proposed to simulate using Alternative Transient Program (ATP) software. Several procedures have been following to calculate Pinceti arrester model parameters so that compatible with 132kV overhead transmission line system. Tested result by simulation is compared with the manufacturer arrester datasheet to evaluate accuracy of Pinceti model before installed arrester at 132kV transmission line model. Pinceti model are installed at several locations on the transmission line model to evaluate the level of effectiveness and capabilities to reduce the level of overvoltage across insulator string and to ensure lightning overcurrent draws to ground totally."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dc:title","label":"Title","values":["Fast transient simulation of pinceti surge arrester model on a transmission line using ATP Software"]}]}],"canonical_facts":{"dc:creator":["Muhamad, Yusof"],"dc:date":["2015-01"],"dc:date.issued":["2015-01"],"dc:description.abstract":["Lightning is one of the main causes of overvoltage on power system. Over voltages problem at the transmission line can cause flashover voltage at the insulator string, power system disturbances and transformer failure. To prevent of insulator string and equipment of the power system from damaging effect by lightning overvoltage, metal oxide surge arrester is installed at overhead line in parallel with insulator string. Due to metal oxide surge arrester have dynamic behaviour, this arrester can be simulated using non-linear resistor. Therefore Pinceti model is proposed to simulate using Alternative Transient Program (ATP) software. Several procedures have been following to calculate Pinceti arrester model parameters so that compatible with 132kV overhead transmission line system. Tested result by simulation is compared with the manufacturer arrester datasheet to evaluate accuracy of Pinceti model before installed arrester at 132kV transmission line model. Pinceti model are installed at several locations on the transmission line model to evaluate the level of effectiveness and capabilities to reduce the level of overvoltage across insulator string and to ensure lightning overcurrent draws to ground totally."],"dc:format":["text"],"dc:identifier.uri":["http://eprints.uthm.edu.my/1505/1/YUSOF%20MUHAMAD%20COPYRIGHT%20DECLARATION.pdf","http://eprints.uthm.edu.my/1505/2/24p%20YUSOF%20MUHAMAD.pdf","http://eprints.uthm.edu.my/1505/3/YUSOF%20MUHAMAD%20WATERMARK.pdf"],"dc:language":["en"],"dc:publisher.department":["Faculty of Electrical and Electronics Engineering"],"dc:publisher.institution":["Universiti Tun Hussein Onn Malaysia"],"dc:relation.isreferencedby":["http://eprints.uthm.edu.my/1505/"],"dc:subject":["TK3001-3521 Distribution or transmission of electric power"],"dc:title":["Fast transient simulation of pinceti surge arrester model on a transmission line using ATP Software"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["masters"],"dc:type.qualificationname":["mphil"]},"updated_at":"2026-07-24T05:48:31Z"}