{"id":{"repo_id":"utc","oai_identifier":"oai:scholar.utc.edu:theses-1636"},"canonical_url":"https://search.dev.ndltd.org/etd/utc/oai:scholar.utc.edu:theses-1636","repository":{"repo_id":"utc","name":"University of Tennessee - Chattanooga","base_url":"https://scholar.utc.edu/do/oai/"},"display":{"title":"Fast power network detection of topology change locations using PMU measurements","abstract":"System monitoring and contingency analysis are crucial functions in power control centers. In order to perform these analyses, a complete model of the power network is needed. Moreover, to account for system configuration dynamics, this model must be continuously updated for the purpose of on-line analysis. Several topology processing schemes have been developed in the literature to accomplish this task. The majority of these schemes process breaker statuses to detect changes in system topology. Transformer tap positions as well as statuses of capacitor and reactor bank switches must also be included in the process. This results in a complicated topology processing scheme. In this work, a simple and quick method for on-line detection and identification of system topology changes is introduced. This method is based on representing line outages with fictitious nodal power injections. The injections are calculated using system states obtained from phasor measurement units (PMUs). This scheme can be applied on reduced systems where parts of the network are not covered by PMU measurements. The scheme was tested during different outage events in the IEEE39-bus system. The obtained results validated the algorithm’s ability to detect and identify line outage events effectively and efficiently.","abstract_html":"System monitoring and contingency analysis are crucial functions in power control centers. In order to perform these analyses, a complete model of the power network is needed. Moreover, to account for system configuration dynamics, this model must be continuously updated for the purpose of on-line analysis. Several topology processing schemes have been developed in the literature to accomplish this task. The majority of these schemes process breaker statuses to detect changes in system topology. Transformer tap positions as well as statuses of capacitor and reactor bank switches must also be included in the process. This results in a complicated topology processing scheme. In this work, a simple and quick method for on-line detection and identification of system topology changes is introduced. This method is based on representing line outages with fictitious nodal power injections. The injections are calculated using system states obtained from phasor measurement units (PMUs). This scheme can be applied on reduced systems where parts of the network are not covered by PMU measurements. The scheme was tested during different outage events in the IEEE39-bus system. The obtained results validated the algorithm’s ability to detect and identify line outage events effectively and efficiently.","abstract_has_math":false,"creators":["Mohamed, Elamin Ali Elamin"],"institution":"University of Tennessee at Chattanooga","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Eltom, Ahmed H.","Karrar, Abdelrahman A.; Kobet, Gary L.","College of Engineering and Computer Science"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-07-01T07:00:00Z","date_published":"2017-07-01T07:00:00Z","updated_at":"2026-07-24T05:46:28Z","subjects":["Electric power systems -- Automation"],"languages":["English","eng"],"rights":[],"rights_urls":["https://rightsstatements.org/page/InC/1.0/?language=en"],"identifier_entries":[]},"links":{"outbound_url":"https://scholar.utc.edu/theses/482","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Eltom, Ahmed H.","Karrar, Abdelrahman A.; Kobet, Gary L.","College of Engineering and Computer Science"]},{"key":"dc:creator","label":"Author","values":["Mohamed, Elamin Ali Elamin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-12-01T08:00:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-07-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["University of Tennessee at Chattanooga","Chattanooga (Tenn.)"]},{"key":"dc:relation","label":"Dc Relation","values":["Masters Theses and Doctoral Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["Masters theses","Text"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electric power systems -- Automation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English","eng"]},{"key":"dc:rights","label":"Dc Rights","values":["https://rightsstatements.org/page/InC/1.0/?language=en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholar.utc.edu/theses/482"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Dept. of Electrical Engineering","M. S.; A thesis submitted to the faculty of the University of Tennessee at Chattanooga in partial fulfillment of the requirements of the degree of Master of Science."]},{"key":"dc:description.abstract","label":"Abstract","values":["System monitoring and contingency analysis are crucial functions in power control centers. In order to perform these analyses, a complete model of the power network is needed. Moreover, to account for system configuration dynamics, this model must be continuously updated for the purpose of on-line analysis. Several topology processing schemes have been developed in the literature to accomplish this task. The majority of these schemes process breaker statuses to detect changes in system topology. Transformer tap positions as well as statuses of capacitor and reactor bank switches must also be included in the process. This results in a complicated topology processing scheme. In this work, a simple and quick method for on-line detection and identification of system topology changes is introduced. This method is based on representing line outages with fictitious nodal power injections. The injections are calculated using system states obtained from phasor measurement units (PMUs). This scheme can be applied on reduced systems where parts of the network are not covered by PMU measurements. The scheme was tested during different outage events in the IEEE39-bus system. The obtained results validated the algorithm’s ability to detect and identify line outage events effectively and efficiently."]},{"key":"dc:title","label":"Title","values":["Fast power network detection of topology change locations using PMU measurements"]}]}],"canonical_facts":{"dc:contributor":["Eltom, Ahmed H.","Karrar, Abdelrahman A.; Kobet, Gary L.","College of Engineering and Computer Science"],"dc:creator":["Mohamed, Elamin Ali Elamin"],"dc:date":["2016-12-01T08:00:00Z"],"dc:date.available":["2017-07-01T07:00:00Z"],"dc:description":["Dept. of Electrical Engineering","M. S.; A thesis submitted to the faculty of the University of Tennessee at Chattanooga in partial fulfillment of the requirements of the degree of Master of Science."],"dc:description.abstract":["System monitoring and contingency analysis are crucial functions in power control centers. In order to perform these analyses, a complete model of the power network is needed. Moreover, to account for system configuration dynamics, this model must be continuously updated for the purpose of on-line analysis. Several topology processing schemes have been developed in the literature to accomplish this task. The majority of these schemes process breaker statuses to detect changes in system topology. Transformer tap positions as well as statuses of capacitor and reactor bank switches must also be included in the process. This results in a complicated topology processing scheme. In this work, a simple and quick method for on-line detection and identification of system topology changes is introduced. This method is based on representing line outages with fictitious nodal power injections. The injections are calculated using system states obtained from phasor measurement units (PMUs). This scheme can be applied on reduced systems where parts of the network are not covered by PMU measurements. The scheme was tested during different outage events in the IEEE39-bus system. The obtained results validated the algorithm’s ability to detect and identify line outage events effectively and efficiently."],"dc:identifier":["https://scholar.utc.edu/theses/482"],"dc:language":["English","eng"],"dc:publisher":["University of Tennessee at Chattanooga","Chattanooga (Tenn.)"],"dc:relation":["Masters Theses and Doctoral Dissertations"],"dc:rights":["https://rightsstatements.org/page/InC/1.0/?language=en"],"dc:subject":["Electric power systems -- Automation"],"dc:title":["Fast power network detection of topology change locations using PMU measurements"],"dc:type":["Masters theses","Text"]},"updated_at":"2026-07-24T05:46:28Z"}