Back to results

University of Ontario Institute of Technology

Dosimetric characterization of a miniature x-ray source for biophysics studies

Abstract

dc:description.abstract

Tritium is a low energy beta emitter that is found in abundance at CANDU nuclear power plants and is a cause of concern since it accounts for roughly thirty three percent of the total occupational exposure of nuclear workers. According to current standards, the radiation weighting factor for all electrons irrespective of their energies is 1. However, there is some evidence suggesting that this factor for low energy electrons could be more than 1. Due to the complexities associated with handling tritium in a liquid or gaseous state alternate arrangements to simulate tritium radiation are investigated. Therefore, in this project it is proposed to use a miniature X-Ray source (Mini-X) to simulate tritium radiation and characterise these low energy X-Ray beams with the aim of investigating the relative biological effectiveness of low energy electrons. The scope of this study is to design and characterize low energy X-Ray beams, suitable for biophysical experiments using Gafchromic’s XR-QA2 radiochromic film and Standard Imaging’s A-20 ionization chamber. To safely carry out the characterization experiments a dual layered safety shielding was constructed and parameters including beam dimensions, air-kerma and dose to tissue values from the Mini-X were explored. Lastly, a cross calibration curve between an optically stimulated luminescent dosimeter (nanoDots) and A-20 ionization chamber was established, with an aim to use nanoDots for a proposed future biophysical experiment. It was found that the Mini-X produced a flat beam profile at distances up to 12.7 cm from the source. In addition, air-kerma values of 11.56 and 6.442 cGy/s could be obtained at 2.54 cm and 5.08 cm respectively with operating parameters of 20 keV and 75 μA. It was also established that there is no substantial difference between air-kerma and dose to tissue values for the X-Ray beams studied. For future work, a biophysical experiment would be carried out using fish eggs where the impact of the Mini-X X-Ray beams on egg hatchability and embryonic mortality would be measured.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science (MASc)
Discipline thesis:degree_discipline
Nuclear Engineering
Grantor
University of Ontario Institute of Technology
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Virdi, Karanvir Singh
Advisor dc:contributor.advisor
  • Waker, Anthony

Subjects

dc:subject × 4

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10155/575
OAI identifier oai:identifier
oai:ontariotechu.scholaris.ca:10155/575

Chain of custody

source
Harvested from
Ontario Institute of Technology
Base URL
ontariotechu.scholaris.ca/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Virdi, Karanvir Singh. Dosimetric characterization of a miniature x-ray source for biophysics studies. University of Ontario Institute of Technology, 2015. https://hdl.handle.net/10155/575