Back to results

University of Ontario Institute of Technology

Leakage-corrected discontinuity factors for a second-generation Th-Pu pressure-tube SCWR.

Abstract

dc:description.abstract

The neutron flux throughout a reactor core should be calculated, ideally, by solving the neutron transport equation for a highly detailed geometric model of the core. Since this is computationally impractical, approximate node-homogenized models have historically been used whereby neutronic properties are averaged over cartesian parallelepipedic regions called nodes. This process is referred to as homogenization. The simplest homogenization procedure is known as standard homogenization. Standard homogenization calculates node-homogenized cross sections as flux-weighted averages over the volume of each node. It uses an approximate spatial flux distribution obtained from single-node detailed-geometry calculations that approximate the node-boundary conditions to be reflective. While standard homogenization has been successfully used for CANDU reactors, there exist more advanced homogenization methods such as Generalized Equivalence Theory (GET). GET improves accuracy by allowing the neutron flux in the node-homogenized model to be discontinuous at node boundaries through the use of discontinuity factors. Node-averaged cross sections and discontinuity factors can be obtained from single-node calculations using reflective boundary conditions. To further improve accuracy, non-reflective boundary conditions that approximate the real node-boundary conditions can be used; a process known as leakage correction. This work explores the use of GET with leakage-corrected cross sections and discontinuity factors for the next-generation PT-SCWR flux calculations. Results show that using GET in conjunction with leakage corrections yields substantial improvements in accuracy over standard homogenization and should be given serious consideration as a method for performing neutronic calculations for PT-SCWR cores.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science (MASc)
Discipline thesis:degree_discipline
Nuclear Engineering
Grantor
University of Ontario Institute of Technology
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Carisse, Katarzyna
Advisor dc:contributor.advisor
  • Nichita, Eleodor

Subjects

dc:subject × 4

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10155/458
OAI identifier oai:identifier
oai:ontariotechu.scholaris.ca:10155/458

Chain of custody

source
Harvested from
Ontario Institute of Technology
Base URL
ontariotechu.scholaris.ca/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Carisse, Katarzyna. Leakage-corrected discontinuity factors for a second-generation Th-Pu pressure-tube SCWR.. University of Ontario Institute of Technology, 2014. https://hdl.handle.net/10155/458