Back to results

University of Ontario Institute of Technology

Assessment of FLUENT CFD code as an analysis tool for SCW applications

Abstract

dc:description.abstract

Chosen as one of six Generation‒IV nuclear-reactor concepts, SuperCritical Water-cooled Reactors (SCWRs) are expected to have high thermal efficiencies within the range of 45 ‒ 50% owing to the reactor‟s high pressures and outlet temperatures. The behaviour of supercritical water however, is not well understood and most of the methods available to predict the effects of the heat transfer phenomena within the pseudocritical region are based on empirical one-directional correlations which do not capture the multi-dimensional effects and do not provide accurate results in regions such as the deteriorated heat transfer regime. Computational Fluid Dynamics (CFD) is a numerical approach to model fluids in multidimensional space using the Navier-Stokes equations and databases of fluid properties to arrive at a full simulation of a fluid dynamics and heat transfer system. In this work, the CFD code, FLUENT-12, is used with associated software such as Gambit and NIST REFPROP to predict the Heat Transfer Coefficients at the wall and corresponding wall temperature profiles inside vertical bare tubes with SuperCritical Water (SCW) as the cooling medium. The numerical results are compared with experimental data and 1-D models represented by existing empirical correlations. Analysis of the individual heat-transfer regimes is conducted using an axisymmetric 2-D model of tubes of various lengths and composed of different nodes count along the heated length. Wall temperatures and heat transfer coefficients were analyzed to select the best model for each region (below, at and above the pseudocritical region). To neutralize effects of the rest of the tube on that region, smaller meshes were used were possible. Two turbulent models were used in the process: k-ε and k-ω, with many variations in the sub-model parameters such as viscous heating, thermal effects, and low-Reynolds number correction. Results of the analysis show a fit of ±10% for the wall temperatures using the SST k-ω model in the deteriorated heat transfer regime and less than ±5% for the normal heat transfer regime. The accuracy of the model is higher than any empirical correlation tested in the mentioned regimes, and provides additional information about the multidimensional effects between the bulk-fluid and wall temperatures. Despite the improved prediction capability, the numerical solutions indicate that further work is necessary. Each region has a different numerical model and the CFD code cannot cover the entire range in one comprehensive model. Additionally, some of the trends and transitions predicted are difficult to accept as representation of the true physics of SCW flow conditions. While CFD can be used to develop preliminary design solutions for SCW type reactors, a significant effort in experimental work to measure the actual phenomena is important to make further advancements in CFD based analysis of SCW fluid behaviour.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science (MASc)
Discipline thesis:degree_discipline
Nuclear Engineering
Grantor
University of Ontario Institute of Technology
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Farah, Amjad
Advisors dc:contributor.advisor
  • Harvel, Glenn
  • Pioro, Igor

Subjects

dc:subject × 5

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10155/239
OAI identifier oai:identifier
oai:ontariotechu.scholaris.ca:10155/239

Chain of custody

source
Harvested from
Ontario Institute of Technology
Base URL
ontariotechu.scholaris.ca/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Farah, Amjad. Assessment of FLUENT CFD code as an analysis tool for SCW applications. University of Ontario Institute of Technology, 2012. https://hdl.handle.net/10155/239