Back to results

University of Ontario Institute of Technology

Novel thermoluminescent dosemeter for the measurement of the eye lens operational dose equivalent in mixed neutron-gamma radiation fields

Abstract

dc:description.abstract

Based on ICRP 118 (2012) recommendations, the Canadian Nuclear Safety Commission amended the Radiation Protection Regulations in their recent document “REGDOC-2.7.2, Dosimetry, Volume I: Ascertaining Occupational Dose”, reducing the equivalent dose limit for the eye lens of a nuclear energy worker from 150 mSv to 50 mSv in a one-year dosimetry period and to 100 mSv in a five-year dosimetry period, and adding the personal dose equivalent at 3mm soft-tissue depth, Hp(3), to the list of Radiation Protection quantities, as the representative operational quantity for the dose to the lens of the eye. The Hp(3) operational quantity is measured using a dosemeter covered by 3mm of tissue-equivalent material. To date, despite there being some attempts to calculate eye-lens conversion coefficients for neutrons and to evaluate the dose due to occupational exposure by Monte Carlo simulations, no operational eye-lens dosemeters for mixed neutron-gamma fields have been developed anywhere in the world. The objective of this research was to design and manufacture a novel thermoluminescent dosemeter to measure directly the Hp(3) in mixed neutron-gamma fields. A prototype was developed and its applicability to the concurrent measuring of the neutron and gamma operational eye lens dose equivalents in a mixed neutron-gamma field was demonstrated both experimentally and by Monte Carlo simulation with the GEANT4 toolkit.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (PhD)
Discipline thesis:degree_discipline
Nuclear Engineering
Grantor
University of Ontario Institute of Technology
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Beregic, Virgiliu Doru
Advisor dc:contributor.advisor
  • Nichita, Eleodor

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10155/1812
OAI identifier oai:identifier
oai:ontariotechu.scholaris.ca:10155/1812

Chain of custody

source
Harvested from
Ontario Institute of Technology
Base URL
ontariotechu.scholaris.ca/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Beregic, Virgiliu Doru. Novel thermoluminescent dosemeter for the measurement of the eye lens operational dose equivalent in mixed neutron-gamma radiation fields. University of Ontario Institute of Technology, 2024. https://hdl.handle.net/10155/1812