{"id":{"repo_id":"uoit","oai_identifier":"oai:ontariotechu.scholaris.ca:10155/163"},"canonical_url":"https://search.dev.ndltd.org/etd/uoit/oai:ontariotechu.scholaris.ca:10155/163","repository":{"repo_id":"uoit","name":"Ontario Institute of Technology","base_url":"https://ontariotechu.scholaris.ca/server/oai/request"},"display":{"title":"Communication protocols, queuing and scheduling delay analysis in CANDU SCWR hydrogen co-generation model","abstract":"Industrial dynamical, Networked Control Systems (NCSs) are controlled over a communication network. We study a continuous-time CANada Deuterium Uranium-Super Critical Water Reactor (CANDU-SCWR) hydrogen plant and a discrete-time controller, sensor and actuator block, that are connected via a communication network, such as e.g. controller area network (CAN), Ethernet or wireless networks. Issues associated with NCSs are time-varying delays, timevarying sampling intervals and loss of data due to packet drop outs. Delays are also associated with software chosen, control system architecture and computation load. CANDU-SCWR hydrogen co-generation model reliability can be analyzed by dynamic flow graph methodology. We have analyzed the CANDU-SCWR feed water integration with the oxygen unit of copper chloride cycle and also conducted an analytical review of the current networked control system delays.","abstract_html":"Industrial dynamical, Networked Control Systems (NCSs) are controlled over a communication network. We study a continuous-time CANada Deuterium Uranium-Super Critical Water Reactor (CANDU-SCWR) hydrogen plant and a discrete-time controller, sensor and actuator block, that are connected via a communication network, such as e.g. controller area network (CAN), Ethernet or wireless networks. Issues associated with NCSs are time-varying delays, timevarying sampling intervals and loss of data due to packet drop outs. Delays are also associated with software chosen, control system architecture and computation load. CANDU-SCWR hydrogen co-generation model reliability can be analyzed by dynamic flow graph methodology. We have analyzed the CANDU-SCWR feed water integration with the oxygen unit of copper chloride cycle and also conducted an analytical review of the current networked control system delays.","abstract_has_math":false,"creators":["Ahmed, Fayyaz"],"institution":"University of Ontario Institute of Technology","degree_name":"Master of Applied Science (MASc)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Lu, Lixuan","Naterer, Greg"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-08-01","date_published":"2011-08-01","updated_at":"2026-07-24T05:35:43Z","subjects":["CANDU SCWR hydrogen co-generation model","Communication delays","Queuing delays","Scheduling delays"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10155/163","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lu, Lixuan","Naterer, Greg"]},{"key":"dc:creator","label":"Author","values":["Ahmed, Fayyaz"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-09-19T15:25:43Z","2022-03-29T16:33:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-09-19T15:25:43Z","2022-03-29T16:33:51Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-08-01"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (MASc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Ontario Institute of Technology"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["CANDU SCWR hydrogen co-generation model","Communication delays","Queuing delays","Scheduling delays"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10155/163"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Industrial dynamical, Networked Control Systems (NCSs) are controlled over a communication network. We study a continuous-time CANada Deuterium Uranium-Super Critical Water Reactor (CANDU-SCWR) hydrogen plant and a discrete-time controller, sensor and actuator block, that are connected via a communication network, such as e.g. controller area network (CAN), Ethernet or wireless networks. Issues associated with NCSs are time-varying delays, timevarying sampling intervals and loss of data due to packet drop outs. Delays are also associated with software chosen, control system architecture and computation load. CANDU-SCWR hydrogen co-generation model reliability can be analyzed by dynamic flow graph methodology. We have analyzed the CANDU-SCWR feed water integration with the oxygen unit of copper chloride cycle and also conducted an analytical review of the current networked control system delays."]},{"key":"dc:title","label":"Title","values":["Communication protocols, queuing and scheduling delay analysis in CANDU SCWR hydrogen co-generation model"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lu, Lixuan","Naterer, Greg"],"dc:creator":["Ahmed, Fayyaz"],"dc:date.accessioned":["2011-09-19T15:25:43Z","2022-03-29T16:33:51Z"],"dc:date.available":["2011-09-19T15:25:43Z","2022-03-29T16:33:51Z"],"dc:date.issued":["2011-08-01"],"dc:description.abstract":["Industrial dynamical, Networked Control Systems (NCSs) are controlled over a communication network. We study a continuous-time CANada Deuterium Uranium-Super Critical Water Reactor (CANDU-SCWR) hydrogen plant and a discrete-time controller, sensor and actuator block, that are connected via a communication network, such as e.g. controller area network (CAN), Ethernet or wireless networks. Issues associated with NCSs are time-varying delays, timevarying sampling intervals and loss of data due to packet drop outs. Delays are also associated with software chosen, control system architecture and computation load. CANDU-SCWR hydrogen co-generation model reliability can be analyzed by dynamic flow graph methodology. We have analyzed the CANDU-SCWR feed water integration with the oxygen unit of copper chloride cycle and also conducted an analytical review of the current networked control system delays."],"dc:identifier.uri":["https://hdl.handle.net/10155/163"],"dc:language.iso":["en"],"dc:subject":["CANDU SCWR hydrogen co-generation model","Communication delays","Queuing delays","Scheduling delays"],"dc:title":["Communication protocols, queuing and scheduling delay analysis in CANDU SCWR hydrogen co-generation model"],"dc:type":["Thesis"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Applied Science (MASc)"],"thesis:institution_name":["University of Ontario Institute of Technology"]},"updated_at":"2026-07-24T05:35:43Z"}