Back to results

UNSW, Sydney

Engineering and acute physiological testing of a retinal neurostimulator

Abstract

dc:description

Electrical stimulation of retinal neurons is known to elicit visual sensations. When applied to the retina in a spatial pattern, electrical stimulation may be capable of providing rudimentary patterned vision that may be of benefit to sufferers of degenerative retinal disorders. No such device has yet been devised to provide for chronic study of the psychophysical perceptions elicited from a prosthesis for retinal stimulation. In this study, steps towards achieving this goal have been successfully carried out. Foregoing research was reviewed such that appropriate stimulation parameters were incorporated in the design of a 100 stimulation channel, complimentary metal oxide semiconductor (CMOS) integrated circuit, small enough in size so as to be capable of being implanted within the ocular anatomy or surrounding orbit. The device, and its associated external hardware and software were designed, modeled, fabricated, and interfaced with stimulating electrodes in acute testing in a highorder mammal (Ovis aries) so as to assess the capabilities of the device to elicit cortical potentials as a direct result of stimulation of the neural retina. Testing was performed under conditions similar to those anticipated in chronic in-situ configurations wherein radio-frequency telemetry was used to deliver power and configuration parameters to the device thus avoiding the passage of wires through tissue in order to communicate to the implant circuit. The results of the testing indicate that the circuit is indeed capable of eliciting physiological responses in the animal and evidence is present that these responses could be elicited in patterned form. Further work undertaken includes the development of surgical methods for implantation, and application of the prosthesis circuit in functional electronic stimulation.

Degree

thesis:*
Grantor dc:publisher
UNSW, Sydney
Year dc:date
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Suaning, Gregg Jørgen

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • open access
  • CC BY-NC-ND 3.0
  • free_to_read
Language dc:language
EN

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:unsworks.library.unsw.edu.au:1959.4/19203

Chain of custody

source
Harvested from
University of New South Wales
Base URL
unsworks.unsw.edu.au/oai/provider
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Suaning, Gregg Jørgen. Engineering and acute physiological testing of a retinal neurostimulator. UNSW, Sydney, 2003. http://hdl.handle.net/1959.4/19203