{"id":{"repo_id":"uno","oai_identifier":"oai:scholarworks.uno.edu:td-1200"},"canonical_url":"https://search.dev.ndltd.org/etd/uno/oai:scholarworks.uno.edu:td-1200","repository":{"repo_id":"uno","name":"University of New Orleans","base_url":"https://scholarworks.uno.edu/do/oai/"},"display":{"title":"Relationship between the Sludge Settling Characteristics and the Parameters of the Activated Sludge System","abstract":"The activated sludge process is one of the most commonly employed domestic and industrial waste treatment process. Different types of mathematical models have been proposed for design and operation of this process, most of which do not consider the relationship between the sludge settling characteristics and the aeration unit performance. This project studies the validity of a model developed by La Motta (2004b) which links the operating parameters of an activated sludge system and the classical limiting flux sludge settling theory. Favorable results were obtained demonstrating that the model predicts very similar values of the parameters of the system in comparison with the parameters observed in an activated sludge pilot plant that is located within installations of the Marrero Wastewater Treatment Plant, New Orleans, Louisiana. This research also demonstrated that the model is a helpful tool for the design and operation of an activated sludge system.","abstract_html":"The activated sludge process is one of the most commonly employed domestic and industrial waste treatment process. Different types of mathematical models have been proposed for design and operation of this process, most of which do not consider the relationship between the sludge settling characteristics and the aeration unit performance. This project studies the validity of a model developed by La Motta (2004b) which links the operating parameters of an activated sludge system and the classical limiting flux sludge settling theory. Favorable results were obtained demonstrating that the model predicts very similar values of the parameters of the system in comparison with the parameters observed in an activated sludge pilot plant that is located within installations of the Marrero Wastewater Treatment Plant, New Orleans, Louisiana. This research also demonstrated that the model is a helpful tool for the design and operation of an activated sludge system.","abstract_has_math":false,"creators":["Rojas, Jose Angel"],"institution":null,"degree_name":"M.S.","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["La Motta, Enrique","McCorquodale, John A.","Kura, Bhaskar"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-12-17T08:00:00Z","date_published":"2004-12-17T08:00:00Z","updated_at":"2026-07-24T05:28:04Z","subjects":["Activated Sludge Process","Design and Operation","Models","Settling characteristics","Operating parameters"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.uno.edu/td/196","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["La Motta, Enrique","McCorquodale, John A.","Kura, Bhaskar"]},{"key":"dc:creator","label":"Author","values":["Rojas, Jose Angel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Activated Sludge Process","Design and Operation","Models","Settling characteristics","Operating parameters"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.uno.edu/td/196"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The activated sludge process is one of the most commonly employed domestic and industrial waste treatment process. Different types of mathematical models have been proposed for design and operation of this process, most of which do not consider the relationship between the sludge settling characteristics and the aeration unit performance. This project studies the validity of a model developed by La Motta (2004b) which links the operating parameters of an activated sludge system and the classical limiting flux sludge settling theory. Favorable results were obtained demonstrating that the model predicts very similar values of the parameters of the system in comparison with the parameters observed in an activated sludge pilot plant that is located within installations of the Marrero Wastewater Treatment Plant, New Orleans, Louisiana. This research also demonstrated that the model is a helpful tool for the design and operation of an activated sludge system."]},{"key":"dc:title","label":"Title","values":["Relationship between the Sludge Settling Characteristics and the Parameters of the Activated Sludge System"]}]}],"canonical_facts":{"dc:contributor":["La Motta, Enrique","McCorquodale, John A.","Kura, Bhaskar"],"dc:creator":["Rojas, Jose Angel"],"dc:description.abstract":["The activated sludge process is one of the most commonly employed domestic and industrial waste treatment process. Different types of mathematical models have been proposed for design and operation of this process, most of which do not consider the relationship between the sludge settling characteristics and the aeration unit performance. This project studies the validity of a model developed by La Motta (2004b) which links the operating parameters of an activated sludge system and the classical limiting flux sludge settling theory. Favorable results were obtained demonstrating that the model predicts very similar values of the parameters of the system in comparison with the parameters observed in an activated sludge pilot plant that is located within installations of the Marrero Wastewater Treatment Plant, New Orleans, Louisiana. This research also demonstrated that the model is a helpful tool for the design and operation of an activated sludge system."],"dc:identifier":["https://scholarworks.uno.edu/td/196"],"dc:subject":["Activated Sludge Process","Design and Operation","Models","Settling characteristics","Operating parameters"],"dc:title":["Relationship between the Sludge Settling Characteristics and the Parameters of the Activated Sludge System"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["M.S."]},"updated_at":"2026-07-24T05:28:04Z"}