Back to results

University of Nevada, Las Vegas

Calibration of YSZ sensor for the measurement of oxygen concentration in Lbe

Abstract

dc:description.abstract

Although liquid lead-bismuth eutectic (LBE) is a good candidate for coolant in the sub-critical transmutation blanket, it is known to be corrosive to stainless steel tubes and containers used in nuclear installations. To prevent the long-term corrosion problem by producing and maintaining a protective oxide layer on exposed surface of stainless steel, it is essential to accurately measure and control the oxygen concentration dissolved in LBE. An automobile style voltametric oxygen sensors, with YSZ (Yttria Stabilized Zirconia) as electrolyte and molten bismuth saturated with oxygen as reference was selected. An instrumentation system was designed specifically for calibrating the YSZ sensor and measure oxygen concentration in LBE. An initial setup was built and some preliminary experiments were conducted to calibrate the oxygen sensor. A set of calibration curves of voltage vs. temperature ranging from 300°C to 500°C under various oxygen concentrations in liquid LBE was obtained and presented here. A new improvised setup and instrumentation have also been developed to obtain more accurate results for a wide range of temperature between 300°C to 700°C.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Electrical and Computer Engineering
Grantor dc:publisher
University of Nevada, Las Vegas
Year
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sivaraman, Ramkumar B
Contributors dc:contributor
  • Yingtao Jiang

Rights

dc:rights
Statement dc:rights
  • IN COPYRIGHT. For more information about this rights statement, please visit http://rightsstatements.org/vocab/InC/1.0/
Language dc:language
English

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:oasis.library.unlv.edu:rtds-2611

Chain of custody

source
Harvested from
University of Nevada - Las Vegas
Base URL
oasis.library.unlv.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Sivaraman, Ramkumar B. Calibration of YSZ sensor for the measurement of oxygen concentration in Lbe. Thesis thesis, University of Nevada, Las Vegas, 2003. https://doi.org/10.25669/flt2-zyl9