Assessing silica and dissolved oxygen effects on copper corrosion control in southern Nevada water treatment and supply system

Abstract

dc:description.abstract

A pilot plant study was performed to investigate both the effect of silica on the corrosion process in the water system, and the effect of increased oxygen concentration resulting from ozonation on copper corrosion in the water system. The piping system used in the pilot plant resembled a household piping system, and consisted of four loops of copper pipes. Silica was added to the finished water before entering the loops at three different concentrations and corrosion was monitored by measuring copper concentration in first-draw weekly samples taken from the pilot system. Silica addition was monitored on a daily basis. Alkalinity, pH, dissolved oxygen, temperature, and conductivity were also measured, and the corrosivity of each water was calculated; Statistical and thermodynamic chemical analysis were performed to evaluate the results in chapter, and the most effective dosage of silica was determined. An average of 11.3 mg/l applied silica concentration was found the most effective dosage in retarding the corrosion rate. Increased in dissolved oxygen concentration had insignificant effect on dissolved copper concentration; A multiple linear relationship was found to predict copper concentration in loop 1, where no silica was added, as a function of alkalinity and temperature. It was also found that the formation of Cu(OH){dollar}\sb2,{dollar} Cu(CO{dollar}\sb3),{dollar} CuHCO{dollar}\sb3\sp{+1},{dollar} and Cu(CO{dollar}\sb3)\sb2\sp{-2}{dollar} were thermodynamically favored under the experiment conditions in loop 1.

Degree

thesis:*
Name thesis:degree_name
Master of Arts (MA)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Civil and Environmental Engineering
Grantor dc:publisher
University of Nevada, Las Vegas
Year
1998

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Toubat, Abdel-Rahman M
Contributors dc:contributor
  • David James

Rights

dc:rights
Statement dc:rights
  • IN COPYRIGHT. For more information about this rights statement, please visit http://rightsstatements.org/vocab/InC/1.0/

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:oasis.library.unlv.edu:rtds-1857

Chain of custody

source
Harvested from
University of Nevada - Las Vegas
Base URL
oasis.library.unlv.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Toubat, Abdel-Rahman M. Assessing silica and dissolved oxygen effects on copper corrosion control in southern Nevada water treatment and supply system. Thesis thesis, University of Nevada, Las Vegas, 1998. https://doi.org/10.25669/p9kq-4joy