University of Nevada, Las Vegas
The detection of crevice corrosion in titanium and its alloys through the use of potential monitoring
Abstract
dc:description.abstractConventional laboratory crevice corrosion testing requires approximately thirty days and is a simple go/no go test which does not indicate crevice incubation time and propagation. This study focuses on the effectiveness of potential monitoring to detect the onset of crevice corrosion and propagation for several titanium alloys in chloride environments. Utilizing this technique, crevice corrosion initiation is determined after several days, thus a shorter test period is required. This technique may well be suited for field as well as laboratory applications. Crevice corrosion incubation periods and corresponding potential behavior are investigated along with the effect of crevice to uncreviced surface area ratio. Under freely corroding conditions, which better simulate in-service conditions, the relationship between the corrosion potential (Ecorr) and crevice corrosion initiation and propagation was readily determined. Corresponding crevice corrosion initiation and steady state propagation surface morphology was also examined.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Grantor dc:publisher
- University of Nevada, Las Vegas
- Year
- 1991
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bergman, Dave Dror
- Contributors dc:contributor
-
- R. L. Skaggs
Rights
dc:rights- Statement dc:rights
-
- IN COPYRIGHT. For more information about this rights statement, please visit http://rightsstatements.org/vocab/InC/1.0/
- Language dc:language
- English
Identifiers
dc:identifier.*- Identifier
- https://oasis.library.unlv.edu/rtds/160
- OAI identifier oai:identifier
- oai:oasis.library.unlv.edu:rtds-1159