{"id":{"repo_id":"unh-thes","oai_identifier":"oai:scholars.unh.edu:dissertation-1302"},"canonical_url":"https://search.dev.ndltd.org/etd/unh-thes/oai:scholars.unh.edu:dissertation-1302","repository":{"repo_id":"unh-thes","name":"University of New Hampshire","base_url":"https://scholars.unh.edu/do/oai/"},"display":{"title":"Vector polarization observables of the deuteron and a new measurement of the magnetic dipole form factor G(M)","abstract":"<p>A measurement of the vector analyzing power Te11 in elastic electron-deuteron scattering has been performed at the MIT-Bates Linear Accelerator Center using a polarized electron beam, an internal polarized atomic deuterium target, and the symmetric BLAST (Bates Large Acceptance Spectrometer Toroid) detector in the Bates South Hall Ring. The beam helicity dependent target vector asymmetries, simultaneously measured in both sectors of BLAST, allow the extraction of Te11 . To the best of our knowledge this is the first such use of a polarized target to determine Te11 . Furthermore, these data, when combined with measurements of A(Q2) and the target tensor polarization observables T20 and T21 , allow the extraction of the magnetic dipole form factor G M in the low Q2 region.</p>","abstract_html":"&lt;p&gt;A measurement of the vector analyzing power Te11 in elastic electron-deuteron scattering has been performed at the MIT-Bates Linear Accelerator Center using a polarized electron beam, an internal polarized atomic deuterium target, and the symmetric BLAST (Bates Large Acceptance Spectrometer Toroid) detector in the Bates South Hall Ring. The beam helicity dependent target vector asymmetries, simultaneously measured in both sectors of BLAST, allow the extraction of Te11 . To the best of our knowledge this is the first such use of a polarized target to determine Te11 . Furthermore, these data, when combined with measurements of A(Q2) and the target tensor polarization observables T20 and T21 , allow the extraction of the magnetic dipole form factor G M in the low Q2 region.&lt;/p&gt;","abstract_has_math":false,"creators":["Karpius, Peter Joseph"],"institution":null,"degree_name":"Doctor of Philosophy","degree_level":"Dissertation","degree_discipline":null,"degree_department":null,"school":null,"contributors":["John Calarco"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-01-01T08:00:00Z","date_published":"2005-01-01T08:00:00Z","updated_at":"2026-07-24T05:22:12Z","subjects":["Physics","Nuclear","Elementary Particles and High Energy"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://scholars.unh.edu/dissertation/303","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["John Calarco"]},{"key":"dc:creator","label":"Author","values":["Karpius, Peter Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","Nuclear","Elementary Particles and High Energy"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholars.unh.edu/dissertation/303"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>A measurement of the vector analyzing power Te11 in elastic electron-deuteron scattering has been performed at the MIT-Bates Linear Accelerator Center using a polarized electron beam, an internal polarized atomic deuterium target, and the symmetric BLAST (Bates Large Acceptance Spectrometer Toroid) detector in the Bates South Hall Ring. The beam helicity dependent target vector asymmetries, simultaneously measured in both sectors of BLAST, allow the extraction of Te11 . To the best of our knowledge this is the first such use of a polarized target to determine Te11 . Furthermore, these data, when combined with measurements of A(Q2) and the target tensor polarization observables T20 and T21 , allow the extraction of the magnetic dipole form factor G M in the low Q2 region.</p>"]},{"key":"dc:title","label":"Title","values":["Vector polarization observables of the deuteron and a new measurement of the magnetic dipole form factor G(M)"]}]}],"canonical_facts":{"dc:contributor":["John Calarco"],"dc:creator":["Karpius, Peter Joseph"],"dc:description.abstract":["<p>A measurement of the vector analyzing power Te11 in elastic electron-deuteron scattering has been performed at the MIT-Bates Linear Accelerator Center using a polarized electron beam, an internal polarized atomic deuterium target, and the symmetric BLAST (Bates Large Acceptance Spectrometer Toroid) detector in the Bates South Hall Ring. The beam helicity dependent target vector asymmetries, simultaneously measured in both sectors of BLAST, allow the extraction of Te11 . To the best of our knowledge this is the first such use of a polarized target to determine Te11 . Furthermore, these data, when combined with measurements of A(Q2) and the target tensor polarization observables T20 and T21 , allow the extraction of the magnetic dipole form factor G M in the low Q2 region.</p>"],"dc:identifier":["https://scholars.unh.edu/dissertation/303"],"dc:subject":["Physics","Nuclear","Elementary Particles and High Energy"],"dc:title":["Vector polarization observables of the deuteron and a new measurement of the magnetic dipole form factor G(M)"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Doctor of Philosophy"]},"updated_at":"2026-07-24T05:22:12Z"}