Back to results

University of Minnesota

Parallel transmission for magnetic resonance imaging on a 9.4 Tesla Human System.

Abstract

dc:description.abstract

Over recent years, researchers have been increasingly pushing towards using ultrahigh magnetic field (7 Tesla and higher) for magnetic resonance imaging in human to benefit from substantial increases in signal to noise ratio and contrast. However, at ultrahigh field, severe transmit B1 (B1+) inhomogeneity occurs, limiting applications of most conventional MR techniques. Multidimensional spatially selective RF pulses have been proposed as a method to mitigate B1+ inhomogeneity. However, those RF pulses are typically very long and are impractical at high field. Parallel transmission, an emerging technique, makes it possible to design sufficiently short selective RF pulses for use in actual experiments. In this thesis, we demonstrate the first successful implementation of parallel transmission at an ultrahigh field of 9.4 Tesla (T) in the human brain with an eight-channel transmit system, using accelerated (x 4) RF pulses designed to create arbitrarily shaped excitation profiles. To achieve satisfactory excitation accuracy, k-space errors due to gradient system imperfection had to be accurately calibrated and integrated in RF pulse calculation. In order to limit RF power deposition in tissues, an inherent concern for patient safety at very high field, we introduced and demonstrated a new 2D RF pulse design method that effectively reduces specific absorption rate (SAR) while preserving excitation pattern fidelity. SAR reduction efficiency was demonstrated with numerical simulations while excitation pattern fidelity was experimentally verified at 9.4T. Additional preliminary work relevant to B1+ manipulation at high field were also conducted through the course of this thesis, including the implementation of spoke trajectory based transmit excitation with 16 channels at 9.4T, a fast 2D B1 mapping technique and in-depth simulation of SAR in the human brain with multi transmission.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wu, Xiaoping

Subjects

dc:subject × 7

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
http://purl.umn.edu/59499
OAI identifier oai:identifier
oai:conservancy.umn.edu:11299/59499

Chain of custody

source
Harvested from
University of Minnesota
Base URL
conservancy.umn.edu/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Wu, Xiaoping. Parallel transmission for magnetic resonance imaging on a 9.4 Tesla Human System.. 2010. http://purl.umn.edu/59499