{"id":{"repo_id":"umkc","oai_identifier":"oai:mospace.umsystem.edu:10355/45633"},"canonical_url":"https://search.dev.ndltd.org/etd/umkc/oai:mospace.umsystem.edu:10355/45633","repository":{"repo_id":"umkc","name":"University of Missouri - Kansas City","base_url":"https://mospace.umsystem.edu/oai/request"},"display":{"title":"Intraoral Corrosion of Self-ligating Metallic Brackets and Archwires and the Effect on Friction","abstract":"The purpose of this study was to investigate how the frictional coefficient was affected due to intraoral use. A secondary aim of this study was to determine whether or not there was a relationship between corrosion of orthodontic alloys and friction via scanning electron microscopic qualitative analysis. Orthodontic brackets and 0.019 x 0.025 inch stainless steel archwires were collected and divided into three groups of n=10: used bracket and used wires (UBUW), used brackets and new wires (UBNW), and new brackets and new wires (NBNW). ‘New’ materials were as-received from the manufacturer, and ‘used’ materials were clinically used bracket and wires collected from patients following orthodontic treatment. Archwires were pulled through bracket slots at a rate of 0.5mm/min while friction forces were measured. Following a cleaning process, the surface topography of the bracket slots was examined under a scanning electron microscope (SEM). Based on a 1-factor MANOVA, there was no significant group effect (all p>0.05) on frictional forces. Partial eta squared values indicated that intraoral exposure had only a small effect on frictional forces (≤ 3%). Qualitative analysis of SEM images did not show an association between surface characteristics of the bracket slots and magnitude of frictional force. Results suggest that surface corrosion from intraoral use does not significantly affect friction at the bracket wire interface.","abstract_html":"The purpose of this study was to investigate how the frictional coefficient was affected due to intraoral use. A secondary aim of this study was to determine whether or not there was a relationship between corrosion of orthodontic alloys and friction via scanning electron microscopic qualitative analysis. Orthodontic brackets and 0.019 x 0.025 inch stainless steel archwires were collected and divided into three groups of n=10: used bracket and used wires (UBUW), used brackets and new wires (UBNW), and new brackets and new wires (NBNW). ‘New’ materials were as-received from the manufacturer, and ‘used’ materials were clinically used bracket and wires collected from patients following orthodontic treatment. Archwires were pulled through bracket slots at a rate of 0.5mm/min while friction forces were measured. Following a cleaning process, the surface topography of the bracket slots was examined under a scanning electron microscope (SEM). Based on a 1-factor MANOVA, there was no significant group effect (all p&gt;0.05) on frictional forces. Partial eta squared values indicated that intraoral exposure had only a small effect on frictional forces (≤ 3%). Qualitative analysis of SEM images did not show an association between surface characteristics of the bracket slots and magnitude of frictional force. Results suggest that surface corrosion from intraoral use does not significantly affect friction at the bracket wire interface.","abstract_has_math":false,"creators":["Tima, Lori Lynn"],"institution":"University of Missouri--Kansas City","degree_name":"M.S.","degree_level":"Masters","degree_discipline":"Oral and Craniofacial Sciences (UMKC)","degree_department":null,"school":null,"contributors":[],"advisors":["Nickel, Jeffrey C. (Jeffrey Charles), 1957-"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-07-24T05:16:57Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10355/45633","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Nickel, Jeffrey C. (Jeffrey Charles), 1957-"]},{"key":"dc:creator","label":"Author","values":["Tima, Lori Lynn"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-05-26T17:23:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-05-26T17:23:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Oral and Craniofacial Sciences (UMKC)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Missouri--Kansas City"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10355/45633"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Title from PDF of title page, viewed on June 22, 2015","Thesis advisor: Jeffrey Nickel","Vita","Includes bibliographic references (pages 47-50)","Thesis (M.S.)--School of Dentistry. University of Missouri--Kansas City, 2015"]},{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this study was to investigate how the frictional coefficient was affected due to intraoral use. A secondary aim of this study was to determine whether or not there was a relationship between corrosion of orthodontic alloys and friction via scanning electron microscopic qualitative analysis. Orthodontic brackets and 0.019 x 0.025 inch stainless steel archwires were collected and divided into three groups of n=10: used bracket and used wires (UBUW), used brackets and new wires (UBNW), and new brackets and new wires (NBNW). ‘New’ materials were as-received from the manufacturer, and ‘used’ materials were clinically used bracket and wires collected from patients following orthodontic treatment. Archwires were pulled through bracket slots at a rate of 0.5mm/min while friction forces were measured. Following a cleaning process, the surface topography of the bracket slots was examined under a scanning electron microscope (SEM). Based on a 1-factor MANOVA, there was no significant group effect (all p>0.05) on frictional forces. Partial eta squared values indicated that intraoral exposure had only a small effect on frictional forces (≤ 3%). Qualitative analysis of SEM images did not show an association between surface characteristics of the bracket slots and magnitude of frictional force. Results suggest that surface corrosion from intraoral use does not significantly affect friction at the bracket wire interface."]},{"key":"dc:title","label":"Title","values":["Intraoral Corrosion of Self-ligating Metallic Brackets and Archwires and the Effect on Friction"]}]}],"canonical_facts":{"dc:contributor.advisor":["Nickel, Jeffrey C. (Jeffrey Charles), 1957-"],"dc:creator":["Tima, Lori Lynn"],"dc:date.accessioned":["2015-05-26T17:23:17Z"],"dc:date.available":["2015-05-26T17:23:17Z"],"dc:date.issued":["2014"],"dc:description":["Title from PDF of title page, viewed on June 22, 2015","Thesis advisor: Jeffrey Nickel","Vita","Includes bibliographic references (pages 47-50)","Thesis (M.S.)--School of Dentistry. University of Missouri--Kansas City, 2015"],"dc:description.abstract":["The purpose of this study was to investigate how the frictional coefficient was affected due to intraoral use. A secondary aim of this study was to determine whether or not there was a relationship between corrosion of orthodontic alloys and friction via scanning electron microscopic qualitative analysis. Orthodontic brackets and 0.019 x 0.025 inch stainless steel archwires were collected and divided into three groups of n=10: used bracket and used wires (UBUW), used brackets and new wires (UBNW), and new brackets and new wires (NBNW). ‘New’ materials were as-received from the manufacturer, and ‘used’ materials were clinically used bracket and wires collected from patients following orthodontic treatment. Archwires were pulled through bracket slots at a rate of 0.5mm/min while friction forces were measured. Following a cleaning process, the surface topography of the bracket slots was examined under a scanning electron microscope (SEM). Based on a 1-factor MANOVA, there was no significant group effect (all p>0.05) on frictional forces. Partial eta squared values indicated that intraoral exposure had only a small effect on frictional forces (≤ 3%). Qualitative analysis of SEM images did not show an association between surface characteristics of the bracket slots and magnitude of frictional force. Results suggest that surface corrosion from intraoral use does not significantly affect friction at the bracket wire interface."],"dc:identifier.uri":["https://hdl.handle.net/10355/45633"],"dc:title":["Intraoral Corrosion of Self-ligating Metallic Brackets and Archwires and the Effect on Friction"],"thesis:degree_discipline":["Oral and Craniofacial Sciences (UMKC)"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Missouri--Kansas City"]},"updated_at":"2026-07-24T05:16:57Z"}