Back to results

University of Missouri--Kansas City

Performance standards for walk-in coolers and freezers in the United States as a function of local weather conditions

Abstract

dc:description.abstract

Walk-in coolers and freezers are medium (~35º F) and low (~-10º F to -20º F) temperature commercial food preservation equipment, with high market demand. There is considerable potential for energy savings through implementation of energy efficiency measures such as high-efficiency evaporator/condenser fan motors, feedback control systems, automatic door closers, strip curtains, suction line insulation, optimized envelope insulation design, high efficiency lighting, hot gas defrost, evaporator fan controllers, etc. However, minimum efficiency standards for walk-in coolers and freezers have not yet been developed. Development of performance based standards for walk-in coolers and freezers is tantamount to establishing an effective market system in order to achieve energy savings. Development of minimum energy efficiency standards and performance based rating methods requires energy consumption data and cooling capacity data for various walk-in refrigeration system components as functions of the dry-bulb and wet-bulb temperatures of the ambient air surrounding the walk-in box and the condensing unit. In this project, walk-in cooler and freezer models were developed and their performance was simulated using Pack Calculation II software (Danfoss, 2009), in an effort to determine the annual energy consumption and total cooling for a set of representative climatic zones in the United States. Using this data, a performance metric, referred to as the Annual Energy Efficiency Ratio (AEER), was developed to estimate the annual energy efficiency of walk-in coolers and freezers. A simplified testing method based on two representative condensing temperatures to calculate AEER was developed and demonstrated in this research project, based on the hourly ambient temperature data of twelve representative climatic zones in the United States of America. This technique can also be applied to any geographical location with climatic conditions similar to the twelve locations analyzed in this project. This simplified testing method will provide manufacturers with a practical and cost effective technique to test the annual performance of the walk-in refrigeration equipment and to improve operating efficiency. AEER values of walk-in freezer and cooler designs estimated in the current project using the proposed simulation technique closely matched with EER values published in the Federal Register Vol. 75, No.1, Jan 2010, Department of Energy.

Degree

thesis:*
Name thesis:degree_name
Ph.D.
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering (UMKC)
Grantor dc:publisher
University of Missouri--Kansas City
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Anupindi, Raja Srinivas Rao
Advisor dc:contributor.advisor
  • Becker, Bryan R.

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10355/10809
OAI identifier oai:identifier
oai:mospace.umsystem.edu:10355/10809

Chain of custody

source
Harvested from
University of Missouri - Kansas City
Base URL
mospace.umsystem.edu/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Anupindi, Raja Srinivas Rao. Performance standards for walk-in coolers and freezers in the United States as a function of local weather conditions. Doctoral thesis, University of Missouri--Kansas City, 2011. http://hdl.handle.net/10355/10809