{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/95453"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/95453","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Portable biomedical measurement devices: MoboSens and impedance sensing systems","abstract":"Human health has become a very important topic as society pays more attention to the people’s quality of life. Therefore, wearable devices with the capability of monitoring various human health indexes and detecting environmental pollution metrics are in great demand. In this thesis, two methods will be discussed in detail. One method that has been developed to perform the tests is called electrochemical sensing, ‘MoboSens’. It uses a smartphone as its sensing platform with an integrated plug-and-play microelectronic ionic sensor, and the whole package is connected through the audio jack on the smartphone. It is used to measure nitrate concentration in water portably. The other method is called impedance sensing measurement. A portable device is used as the platform to combine with the impedance-based sensing technologies. It is designed to detect some species of Escherichia coli and Salmonella bacteria. The work discusses the system-level circuit design for the prototypes of both methods. The testing results from these two sensing methods have been confirmed with other existing analytical testing methods.","abstract_html":"Human health has become a very important topic as society pays more attention to the people’s quality of life. Therefore, wearable devices with the capability of monitoring various human health indexes and detecting environmental pollution metrics are in great demand. In this thesis, two methods will be discussed in detail. One method that has been developed to perform the tests is called electrochemical sensing, ‘MoboSens’. It uses a smartphone as its sensing platform with an integrated plug-and-play microelectronic ionic sensor, and the whole package is connected through the audio jack on the smartphone. It is used to measure nitrate concentration in water portably. The other method is called impedance sensing measurement. A portable device is used as the platform to combine with the impedance-based sensing technologies. It is designed to detect some species of Escherichia coli and Salmonella bacteria. The work discusses the system-level circuit design for the prototypes of both methods. The testing results from these two sensing methods have been confirmed with other existing analytical testing methods.","abstract_has_math":false,"creators":["Zhang, Han"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"M.S.","degree_level":"Thesis","degree_discipline":"Electrical & Computer Engr","degree_department":null,"school":null,"contributors":["Liu, Gang Logan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-03-01T16:36:39Z","date_published":"2017-03-01T16:36:39Z","updated_at":"2026-07-22T22:26:37Z","subjects":["Smartphone","System-level circuit design","Potentiostat","Impedance sensing","Electrochemical sensing"],"languages":["en"],"rights":["Copyright 2016 Han Zhang"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/95453","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Liu, Gang Logan"]},{"key":"dc:creator","label":"Author","values":["Zhang, Han"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-03-01T16:36:39Z","2019-03-02T10:15:14Z","2016-09-16","2016-12"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical & Computer Engr"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Smartphone","System-level circuit design","Potentiostat","Impedance sensing","Electrochemical sensing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2016 Han Zhang"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/95453"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Human health has become a very important topic as society pays more attention to the people’s quality of life. Therefore, wearable devices with the capability of monitoring various human health indexes and detecting environmental pollution metrics are in great demand. In this thesis, two methods will be discussed in detail. One method that has been developed to perform the tests is called electrochemical sensing, ‘MoboSens’. It uses a smartphone as its sensing platform with an integrated plug-and-play microelectronic ionic sensor, and the whole package is connected through the audio jack on the smartphone. It is used to measure nitrate concentration in water portably. The other method is called impedance sensing measurement. A portable device is used as the platform to combine with the impedance-based sensing technologies. It is designed to detect some species of Escherichia coli and Salmonella bacteria. The work discusses the system-level circuit design for the prototypes of both methods. The testing results from these two sensing methods have been confirmed with other existing analytical testing methods.","Submission published under a 24 month embargo labeled 'U of I Access', the embargo will last until 2018-12-01","The student, Han Zhang, accepted the attached license on 2016-09-14 at 15:13.","The student, Han Zhang, submitted this Thesis for approval on 2016-09-14 at 15:33.","This Thesis was approved for publication on 2016-09-16 at 13:09.","DSpace SAF Submission Ingestion Package generated from Vireo submission #10157 on 2017-02-28 at 14:35:57","Made available in DSpace on 2017-03-01T16:36:39Z (GMT). No. of bitstreams: 2 ZHANG-THESIS-2016.pdf: 991590 bytes, checksum: 11235aa6c54472ec71e0d69b70ff8ec7 (MD5) LICENSE.txt: 4206 bytes, checksum: 0e054176f6ab990c50f8ad8030f4fbca (MD5) Previous issue date: 2016-09-16","Embargo set by: Seth Robbins for item 98569 Lift date: 2019-03-01T16:37:19Z Reason: Author requested U of Illinois access only (OA after 2yrs) in Vireo ETD system","U of I Only Restriction Lifted for Item 98569 on 2019-03-02T10:15:14Z."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Portable biomedical measurement devices: MoboSens and impedance sensing systems"]}]}],"canonical_facts":{"dc:contributor":["Liu, Gang Logan"],"dc:creator":["Zhang, Han"],"dc:date":["2017-03-01T16:36:39Z","2019-03-02T10:15:14Z","2016-09-16","2016-12"],"dc:description":["Human health has become a very important topic as society pays more attention to the people’s quality of life. Therefore, wearable devices with the capability of monitoring various human health indexes and detecting environmental pollution metrics are in great demand. In this thesis, two methods will be discussed in detail. One method that has been developed to perform the tests is called electrochemical sensing, ‘MoboSens’. It uses a smartphone as its sensing platform with an integrated plug-and-play microelectronic ionic sensor, and the whole package is connected through the audio jack on the smartphone. It is used to measure nitrate concentration in water portably. The other method is called impedance sensing measurement. A portable device is used as the platform to combine with the impedance-based sensing technologies. It is designed to detect some species of Escherichia coli and Salmonella bacteria. The work discusses the system-level circuit design for the prototypes of both methods. The testing results from these two sensing methods have been confirmed with other existing analytical testing methods.","Submission published under a 24 month embargo labeled 'U of I Access', the embargo will last until 2018-12-01","The student, Han Zhang, accepted the attached license on 2016-09-14 at 15:13.","The student, Han Zhang, submitted this Thesis for approval on 2016-09-14 at 15:33.","This Thesis was approved for publication on 2016-09-16 at 13:09.","DSpace SAF Submission Ingestion Package generated from Vireo submission #10157 on 2017-02-28 at 14:35:57","Made available in DSpace on 2017-03-01T16:36:39Z (GMT). No. of bitstreams: 2 ZHANG-THESIS-2016.pdf: 991590 bytes, checksum: 11235aa6c54472ec71e0d69b70ff8ec7 (MD5) LICENSE.txt: 4206 bytes, checksum: 0e054176f6ab990c50f8ad8030f4fbca (MD5) Previous issue date: 2016-09-16","Embargo set by: Seth Robbins for item 98569 Lift date: 2019-03-01T16:37:19Z Reason: Author requested U of Illinois access only (OA after 2yrs) in Vireo ETD system","U of I Only Restriction Lifted for Item 98569 on 2019-03-02T10:15:14Z."],"dc:format":["application/pdf"],"dc:identifier":["http://hdl.handle.net/2142/95453"],"dc:language":["en"],"dc:rights":["Copyright 2016 Han Zhang"],"dc:subject":["Smartphone","System-level circuit design","Potentiostat","Impedance sensing","Electrochemical sensing"],"dc:title":["Portable biomedical measurement devices: MoboSens and impedance sensing systems"],"dc:type":["text"],"thesis:degree_discipline":["Electrical & Computer Engr"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:37Z"}