{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/90568"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/90568","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Evaluation of a pneumatic ankle-foot orthosis: portability and functionality","abstract":"There are currently many challenges in creating portable human-assistive robotics and exoskeletons, although the need for robotic human assist continues to grow. These challenges span disciplines such as control, design, fuel and efficiency, user-interfaces, neuroscience, and kinesiology. Our lab has developed a pneumatically powered ankle-foot orthosis (PPAFO) to address some of these issues. In this dissertation, we address the issue of availability of portable pneumatic power sources, and we evaluate the short-term kinematic and metabolic impact of a bilateral, bidirectional portable powered ankle-foot orthosis (PPAFO) in an able-bodied population during over-ground walking, and we evaluate the kinematic and metabolic impact of a unilateral, bidirectional portable powered ankle-foot orthosis (PPAFO) in persons with gait impairment due to Multiple Sclerosis. First, in Chapter 2, we address the state of portable powered pneumatic power sources. Specifically, we evaluated the use of compressed gas tanks with carbon dioxide or nitrogen as fuel. A test bench model of the PPAFO and walking trials (treadmill and over-ground) were used to evaluate each tank and gas, investigating normalized run time, minimum tank temperature, and rate of cooling. We concluded that compressed gas tanks can be used to successfully power portable pneumatic robotic platforms, especially when a recycling circuit can be implemented to increase the longevity of the fuel source, but considerations need to be taken into account in order to determine the proper fuel, based on size, weight, cost, and availability. In Chapter 3, we evaluated a bidirectional, bilateral powered ankle-foot orthosis or exoskeleton system during over-ground walking in able-bodied individuals. With the powered PPAFOs, participants were able to reduce the metabolic power needed for walking compared to the unpowered PPAFO condition, and they were able to match the minimum metabolic power needed in shoes walking. Some kinematic changes were seen while using the PPAFOs, specifically an unexpected reduction in plantarflexion during toe-off. In Chapters 4 and 5, we evaluated the use of a bidirectional powered ankle-foot orthosis to assist persons with gait impairment due to multiple sclerosis. Use of the current embodiment of the portable powered AFO did not improve gait performance as measured by spatiotemporal parameters of gait. Significant differences in kinematic parameters at the ankle were observed such that the PPAFO was able to provide better assistance for foot drop during swing than the AFO or a shoes condition. Changes in kinematics at the knee were found such that the changes are likely due to compensatory reactions to the changes at the ankle induced by the footwear. Throughout this work, we have been motivated to further research the mechanical design of the device so that users can better match their natural gait pattern in regards to spatiotemporal and kinematic parameters. Improving device design and functionality will help to determine if powered orthoses can be effective at assisting and improving gait function in persons with gait impairment.","abstract_html":"There are currently many challenges in creating portable human-assistive robotics and exoskeletons, although the need for robotic human assist continues to grow. These challenges span disciplines such as control, design, fuel and efficiency, user-interfaces, neuroscience, and kinesiology. Our lab has developed a pneumatically powered ankle-foot orthosis (PPAFO) to address some of these issues. In this dissertation, we address the issue of availability of portable pneumatic power sources, and we evaluate the short-term kinematic and metabolic impact of a bilateral, bidirectional portable powered ankle-foot orthosis (PPAFO) in an able-bodied population during over-ground walking, and we evaluate the kinematic and metabolic impact of a unilateral, bidirectional portable powered ankle-foot orthosis (PPAFO) in persons with gait impairment due to Multiple Sclerosis. First, in Chapter 2, we address the state of portable powered pneumatic power sources. Specifically, we evaluated the use of compressed gas tanks with carbon dioxide or nitrogen as fuel. A test bench model of the PPAFO and walking trials (treadmill and over-ground) were used to evaluate each tank and gas, investigating normalized run time, minimum tank temperature, and rate of cooling. We concluded that compressed gas tanks can be used to successfully power portable pneumatic robotic platforms, especially when a recycling circuit can be implemented to increase the longevity of the fuel source, but considerations need to be taken into account in order to determine the proper fuel, based on size, weight, cost, and availability. In Chapter 3, we evaluated a bidirectional, bilateral powered ankle-foot orthosis or exoskeleton system during over-ground walking in able-bodied individuals. With the powered PPAFOs, participants were able to reduce the metabolic power needed for walking compared to the unpowered PPAFO condition, and they were able to match the minimum metabolic power needed in shoes walking. Some kinematic changes were seen while using the PPAFOs, specifically an unexpected reduction in plantarflexion during toe-off. In Chapters 4 and 5, we evaluated the use of a bidirectional powered ankle-foot orthosis to assist persons with gait impairment due to multiple sclerosis. Use of the current embodiment of the portable powered AFO did not improve gait performance as measured by spatiotemporal parameters of gait. Significant differences in kinematic parameters at the ankle were observed such that the PPAFO was able to provide better assistance for foot drop during swing than the AFO or a shoes condition. Changes in kinematics at the knee were found such that the changes are likely due to compensatory reactions to the changes at the ankle induced by the footwear. Throughout this work, we have been motivated to further research the mechanical design of the device so that users can better match their natural gait pattern in regards to spatiotemporal and kinematic parameters. Improving device design and functionality will help to determine if powered orthoses can be effective at assisting and improving gait function in persons with gait impairment.","abstract_has_math":false,"creators":["Boes, Morgan K."],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Bioengineering","degree_department":null,"school":null,"contributors":["Hsiao-Wecksler, Elizabeth T.","Boppart, Stephen","Motl, Robert","Durfee, William"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-07-07T19:54:14Z","date_published":"2016-07-07T19:54:14Z","updated_at":"2026-07-22T22:26:32Z","subjects":["exoskeletons","pneumatic robots","biomechanics","rehabilitation","multiple sclerosis","ankle-foot orthosis","powered orthoses","gait"],"languages":["en"],"rights":["Copyright 2016 Morgan K. Boes"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/90568","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hsiao-Wecksler, Elizabeth T.","Boppart, Stephen","Motl, Robert","Durfee, William"]},{"key":"dc:creator","label":"Author","values":["Boes, Morgan K."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-07-07T19:54:14Z","2016-04-20","2016-05"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Bioengineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["exoskeletons","pneumatic robots","biomechanics","rehabilitation","multiple sclerosis","ankle-foot orthosis","powered orthoses","gait"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2016 Morgan K. Boes"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/90568"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["There are currently many challenges in creating portable human-assistive robotics and exoskeletons, although the need for robotic human assist continues to grow. These challenges span disciplines such as control, design, fuel and efficiency, user-interfaces, neuroscience, and kinesiology. Our lab has developed a pneumatically powered ankle-foot orthosis (PPAFO) to address some of these issues. In this dissertation, we address the issue of availability of portable pneumatic power sources, and we evaluate the short-term kinematic and metabolic impact of a bilateral, bidirectional portable powered ankle-foot orthosis (PPAFO) in an able-bodied population during over-ground walking, and we evaluate the kinematic and metabolic impact of a unilateral, bidirectional portable powered ankle-foot orthosis (PPAFO) in persons with gait impairment due to Multiple Sclerosis. First, in Chapter 2, we address the state of portable powered pneumatic power sources. Specifically, we evaluated the use of compressed gas tanks with carbon dioxide or nitrogen as fuel. A test bench model of the PPAFO and walking trials (treadmill and over-ground) were used to evaluate each tank and gas, investigating normalized run time, minimum tank temperature, and rate of cooling. We concluded that compressed gas tanks can be used to successfully power portable pneumatic robotic platforms, especially when a recycling circuit can be implemented to increase the longevity of the fuel source, but considerations need to be taken into account in order to determine the proper fuel, based on size, weight, cost, and availability. In Chapter 3, we evaluated a bidirectional, bilateral powered ankle-foot orthosis or exoskeleton system during over-ground walking in able-bodied individuals. With the powered PPAFOs, participants were able to reduce the metabolic power needed for walking compared to the unpowered PPAFO condition, and they were able to match the minimum metabolic power needed in shoes walking. Some kinematic changes were seen while using the PPAFOs, specifically an unexpected reduction in plantarflexion during toe-off. In Chapters 4 and 5, we evaluated the use of a bidirectional powered ankle-foot orthosis to assist persons with gait impairment due to multiple sclerosis. Use of the current embodiment of the portable powered AFO did not improve gait performance as measured by spatiotemporal parameters of gait. Significant differences in kinematic parameters at the ankle were observed such that the PPAFO was able to provide better assistance for foot drop during swing than the AFO or a shoes condition. Changes in kinematics at the knee were found such that the changes are likely due to compensatory reactions to the changes at the ankle induced by the footwear. Throughout this work, we have been motivated to further research the mechanical design of the device so that users can better match their natural gait pattern in regards to spatiotemporal and kinematic parameters. Improving device design and functionality will help to determine if powered orthoses can be effective at assisting and improving gait function in persons with gait impairment.","Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2016-07-07 without embargo terms","The student, Morgan Boes, accepted the attached license on 2016-04-18 at 16:55.","The student, Morgan Boes, submitted this Dissertation for approval on 2016-04-18 at 21:17.","This Dissertation was approved for publication on 2016-04-20 at 15:48.","DSpace SAF Submission Ingestion Package generated from Vireo submission #9316 on 2016-07-07 at 13:31:16","Made available in DSpace on 2016-07-07T19:54:14Z (GMT). No. of bitstreams: 21 BOES-DISSERTATION-2016.pdf: 4846474 bytes, checksum: 6bd944978af386008bf02b01ba8030bb (MD5) Dissertation_MBoes_edits_final.docx: 28293488 bytes, checksum: 5b03461a2d4a31c08b585bfa5b679f54 (MD5) LICENSE.txt: 4208 bytes, checksum: 69bd8776ed7dec4e59037595e5d6156a (MD5) MKB_1_10_Wall-X.pdf: 683603 bytes, checksum: 86247a56b2cf62ee8f60481e39beda65 (MD5) MKB_1_11_Mooney_2014_IEEE.pdf: 333225 bytes, checksum: bfbcc39f13e76aafe92fa2007958b4b5 (MD5) MKB_1_12_Neubauer_2014_IEEE.pdf: 335726 bytes, checksum: 5383aec91351017bb054abd65eebec36 (MD5) MKB_1_14_Hofacker_2013_ASME.pdf: 960758 bytes, checksum: 8c6080e1d0e35dd483cd489188331ce4 (MD5) MKB_1_15_Shepherd_2013_Figure 1.pdf: 1962227 bytes, checksum: f03851a420424faf7fa2f54c6aefb040 (MD5) MKB_1_16_Kim_2014_Figure.pdf: 498731 bytes, checksum: c8157696b070134e2fad9e82b32eb8a4 (MD5) MKB_1_17_Wu_2009.pdf: 1040240 bytes, checksum: ccf088870d1da9762b71601d6b015c38 (MD5) MKB_1_18_Wening_2013_approval_fig 1.pdf: 2923185 bytes, checksum: 791f7e9f72d1bdb92d7e1647d9ce4aae (MD5) MKB_1_19_McLoughlin_2015_Figure 1_permission.pdf: 2943219 bytes, checksum: 4b4a7553fb589bb16ff397236958d70d (MD5) MKB_1_20_Hwang_2013.pdf: 1183315 bytes, checksum: 9d43e03c30cda3e542598e11d9c77932 (MD5) MKB_1_5_Ferris_2005_Figure 1.pdf: 2488539 bytes, checksum: b801dd488bc6560e9e183357c58b23a0 (MD5) MKB_1_6_Ferris_2006_Figure 1.pdf: 2877245 bytes, checksum: ef50b79c3e2a47262ca0b67b41ef4fc0 (MD5) MKB_1_7_Gordon_2007_Figure 1.pdf: 2915939 bytes, checksum: c2d671bc98b462e539c3e649646c2616 (MD5) MKB_1_8_Kao_2010_Figure 1.pdf: 2922844 bytes, checksum: cc20b021172e0cdfc73d82c33b6527f8 (MD5) MKB_1_9A_Norris_2007_Figure 1.pdf: 2926023 bytes, checksum: d34efdf444a0ea6c711221527c264b8f (MD5) MKB_1_9B_Norris_2007_ASME.pdf: 960758 bytes, checksum: 8c6080e1d0e35dd483cd489188331ce4 (MD5) MKB_2_2_ClinicalGaitAnalysisFigure_approval.pdf: 219046 bytes, checksum: b3ada8fe4cd855b899673d372409d52b (MD5) PROQUEST_LICENSE.txt: 4554 bytes, checksum: ebff8a285fdadee6f510a741fb50ba1d (MD5) Previous issue date: 2016-04-20"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Evaluation of a pneumatic ankle-foot orthosis: portability and functionality"]}]}],"canonical_facts":{"dc:contributor":["Hsiao-Wecksler, Elizabeth T.","Boppart, Stephen","Motl, Robert","Durfee, William"],"dc:creator":["Boes, Morgan K."],"dc:date":["2016-07-07T19:54:14Z","2016-04-20","2016-05"],"dc:description":["There are currently many challenges in creating portable human-assistive robotics and exoskeletons, although the need for robotic human assist continues to grow. These challenges span disciplines such as control, design, fuel and efficiency, user-interfaces, neuroscience, and kinesiology. Our lab has developed a pneumatically powered ankle-foot orthosis (PPAFO) to address some of these issues. In this dissertation, we address the issue of availability of portable pneumatic power sources, and we evaluate the short-term kinematic and metabolic impact of a bilateral, bidirectional portable powered ankle-foot orthosis (PPAFO) in an able-bodied population during over-ground walking, and we evaluate the kinematic and metabolic impact of a unilateral, bidirectional portable powered ankle-foot orthosis (PPAFO) in persons with gait impairment due to Multiple Sclerosis. First, in Chapter 2, we address the state of portable powered pneumatic power sources. Specifically, we evaluated the use of compressed gas tanks with carbon dioxide or nitrogen as fuel. A test bench model of the PPAFO and walking trials (treadmill and over-ground) were used to evaluate each tank and gas, investigating normalized run time, minimum tank temperature, and rate of cooling. We concluded that compressed gas tanks can be used to successfully power portable pneumatic robotic platforms, especially when a recycling circuit can be implemented to increase the longevity of the fuel source, but considerations need to be taken into account in order to determine the proper fuel, based on size, weight, cost, and availability. In Chapter 3, we evaluated a bidirectional, bilateral powered ankle-foot orthosis or exoskeleton system during over-ground walking in able-bodied individuals. With the powered PPAFOs, participants were able to reduce the metabolic power needed for walking compared to the unpowered PPAFO condition, and they were able to match the minimum metabolic power needed in shoes walking. Some kinematic changes were seen while using the PPAFOs, specifically an unexpected reduction in plantarflexion during toe-off. In Chapters 4 and 5, we evaluated the use of a bidirectional powered ankle-foot orthosis to assist persons with gait impairment due to multiple sclerosis. Use of the current embodiment of the portable powered AFO did not improve gait performance as measured by spatiotemporal parameters of gait. Significant differences in kinematic parameters at the ankle were observed such that the PPAFO was able to provide better assistance for foot drop during swing than the AFO or a shoes condition. Changes in kinematics at the knee were found such that the changes are likely due to compensatory reactions to the changes at the ankle induced by the footwear. Throughout this work, we have been motivated to further research the mechanical design of the device so that users can better match their natural gait pattern in regards to spatiotemporal and kinematic parameters. Improving device design and functionality will help to determine if powered orthoses can be effective at assisting and improving gait function in persons with gait impairment.","Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2016-07-07 without embargo terms","The student, Morgan Boes, accepted the attached license on 2016-04-18 at 16:55.","The student, Morgan Boes, submitted this Dissertation for approval on 2016-04-18 at 21:17.","This Dissertation was approved for publication on 2016-04-20 at 15:48.","DSpace SAF Submission Ingestion Package generated from Vireo submission #9316 on 2016-07-07 at 13:31:16","Made available in DSpace on 2016-07-07T19:54:14Z (GMT). No. of bitstreams: 21 BOES-DISSERTATION-2016.pdf: 4846474 bytes, checksum: 6bd944978af386008bf02b01ba8030bb (MD5) Dissertation_MBoes_edits_final.docx: 28293488 bytes, checksum: 5b03461a2d4a31c08b585bfa5b679f54 (MD5) LICENSE.txt: 4208 bytes, checksum: 69bd8776ed7dec4e59037595e5d6156a (MD5) MKB_1_10_Wall-X.pdf: 683603 bytes, checksum: 86247a56b2cf62ee8f60481e39beda65 (MD5) MKB_1_11_Mooney_2014_IEEE.pdf: 333225 bytes, checksum: bfbcc39f13e76aafe92fa2007958b4b5 (MD5) MKB_1_12_Neubauer_2014_IEEE.pdf: 335726 bytes, checksum: 5383aec91351017bb054abd65eebec36 (MD5) MKB_1_14_Hofacker_2013_ASME.pdf: 960758 bytes, checksum: 8c6080e1d0e35dd483cd489188331ce4 (MD5) MKB_1_15_Shepherd_2013_Figure 1.pdf: 1962227 bytes, checksum: f03851a420424faf7fa2f54c6aefb040 (MD5) MKB_1_16_Kim_2014_Figure.pdf: 498731 bytes, checksum: c8157696b070134e2fad9e82b32eb8a4 (MD5) MKB_1_17_Wu_2009.pdf: 1040240 bytes, checksum: ccf088870d1da9762b71601d6b015c38 (MD5) MKB_1_18_Wening_2013_approval_fig 1.pdf: 2923185 bytes, checksum: 791f7e9f72d1bdb92d7e1647d9ce4aae (MD5) MKB_1_19_McLoughlin_2015_Figure 1_permission.pdf: 2943219 bytes, checksum: 4b4a7553fb589bb16ff397236958d70d (MD5) MKB_1_20_Hwang_2013.pdf: 1183315 bytes, checksum: 9d43e03c30cda3e542598e11d9c77932 (MD5) MKB_1_5_Ferris_2005_Figure 1.pdf: 2488539 bytes, checksum: b801dd488bc6560e9e183357c58b23a0 (MD5) MKB_1_6_Ferris_2006_Figure 1.pdf: 2877245 bytes, checksum: ef50b79c3e2a47262ca0b67b41ef4fc0 (MD5) MKB_1_7_Gordon_2007_Figure 1.pdf: 2915939 bytes, checksum: c2d671bc98b462e539c3e649646c2616 (MD5) MKB_1_8_Kao_2010_Figure 1.pdf: 2922844 bytes, checksum: cc20b021172e0cdfc73d82c33b6527f8 (MD5) MKB_1_9A_Norris_2007_Figure 1.pdf: 2926023 bytes, checksum: d34efdf444a0ea6c711221527c264b8f (MD5) MKB_1_9B_Norris_2007_ASME.pdf: 960758 bytes, checksum: 8c6080e1d0e35dd483cd489188331ce4 (MD5) MKB_2_2_ClinicalGaitAnalysisFigure_approval.pdf: 219046 bytes, checksum: b3ada8fe4cd855b899673d372409d52b (MD5) PROQUEST_LICENSE.txt: 4554 bytes, checksum: ebff8a285fdadee6f510a741fb50ba1d (MD5) Previous issue date: 2016-04-20"],"dc:format":["application/pdf"],"dc:identifier":["http://hdl.handle.net/2142/90568"],"dc:language":["en"],"dc:rights":["Copyright 2016 Morgan K. Boes"],"dc:subject":["exoskeletons","pneumatic robots","biomechanics","rehabilitation","multiple sclerosis","ankle-foot orthosis","powered orthoses","gait"],"dc:title":["Evaluation of a pneumatic ankle-foot orthosis: portability and functionality"],"dc:type":["text"],"thesis:degree_discipline":["Bioengineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:32Z"}