{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/86069"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/86069","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Airborne Pollutant Spatial Distribution, Emission, and Ventilation Effectiveness for Mechanically Ventilated Livestock Buildings","abstract":"CFD simulation was used to predict the spatial distribution of particles less than 10 mum in diameter (PM10) in the swine building. Results showed that the magnitude of the predicted concentrations was significantly higher than the measured concentrations which could be attributed to the assumption of the particle generation rate. Thus, the CFD will be useful as a simulation tool in the future if the particle variables (e.g., particle generation rate, particle velocity) in the model can be properly quantified.","abstract_html":"CFD simulation was used to predict the spatial distribution of particles less than 10 mum in diameter (PM10) in the swine building. Results showed that the magnitude of the predicted concentrations was significantly higher than the measured concentrations which could be attributed to the assumption of the particle generation rate. Thus, the CFD will be useful as a simulation tool in the future if the particle variables (e.g., particle generation rate, particle velocity) in the model can be properly quantified.","abstract_has_math":false,"creators":["Jerez, Sheryll Buena"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Agricultural Engineering","degree_department":null,"school":null,"contributors":["Zhang, Yuanhui"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-28T14:53:51Z","date_published":"2015-09-28T14:53:51Z","updated_at":"2026-07-22T22:26:26Z","subjects":["Engineering, Agricultural"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI3290261"],"render_values":[{"text":"(MiAaPQ)AAI3290261","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/86069","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Zhang, Yuanhui"]},{"key":"dc:creator","label":"Author","values":["Jerez, Sheryll Buena"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-28T14:53:51Z","10000-01-01","2007"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Agricultural Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Agricultural"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/86069","(MiAaPQ)AAI3290261"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["CFD simulation was used to predict the spatial distribution of particles less than 10 mum in diameter (PM10) in the swine building. Results showed that the magnitude of the predicted concentrations was significantly higher than the measured concentrations which could be attributed to the assumption of the particle generation rate. Thus, the CFD will be useful as a simulation tool in the future if the particle variables (e.g., particle generation rate, particle velocity) in the model can be properly quantified.","Made available in DSpace on 2015-09-28T14:53:51Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3290261.pdf: 8287599 bytes, checksum: 021534510575c042b0a88087df7aadb2 (MD5) Previous issue date: 2007","Embargo set by: Seth Robbins for item 87350 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","276 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2007."]},{"key":"dc:title","label":"Title","values":["Airborne Pollutant Spatial Distribution, Emission, and Ventilation Effectiveness for Mechanically Ventilated Livestock Buildings"]}]}],"canonical_facts":{"dc:contributor":["Zhang, Yuanhui"],"dc:creator":["Jerez, Sheryll Buena"],"dc:date":["2015-09-28T14:53:51Z","10000-01-01","2007"],"dc:description":["CFD simulation was used to predict the spatial distribution of particles less than 10 mum in diameter (PM10) in the swine building. Results showed that the magnitude of the predicted concentrations was significantly higher than the measured concentrations which could be attributed to the assumption of the particle generation rate. Thus, the CFD will be useful as a simulation tool in the future if the particle variables (e.g., particle generation rate, particle velocity) in the model can be properly quantified.","Made available in DSpace on 2015-09-28T14:53:51Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3290261.pdf: 8287599 bytes, checksum: 021534510575c042b0a88087df7aadb2 (MD5) Previous issue date: 2007","Embargo set by: Seth Robbins for item 87350 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","276 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2007."],"dc:identifier":["http://hdl.handle.net/2142/86069","(MiAaPQ)AAI3290261"],"dc:language":["eng"],"dc:subject":["Engineering, Agricultural"],"dc:title":["Airborne Pollutant Spatial Distribution, Emission, and Ventilation Effectiveness for Mechanically Ventilated Livestock Buildings"],"dc:type":["text"],"thesis:degree_discipline":["Agricultural Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:26Z"}