{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/85187"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/85187","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"High Resolution Acetic Acid Survey and Water Vapor Radiometer","abstract":"Ground-based interferometric observations are severely affected by atmospheric conditions. Phase correction is a technique to obtain high quality data and achieve great scientific goals. For our acetic acid survey, a better phase correction technique can not only detect weaker transitions of large molecules, but also increase the map resolution of hot cores. Water vapor radiometers (WVRs) are designed to improve the technique by observing tropospheric water vapor along the lines of sight of interferometers. We have numerically demonstrated the importance of phase correction for interferometric observations and examined the water vapor phase correction technique. Furthermore, we have built two WVR prototypes with new calibration, thermal regulation and backend systems. The WVR prototypes had been tested in a laboratory, on a roof and at the CARMA site to verify their performance. We conclude the WVR thermal stability and dynamic range are critical while the enormous and rapid fluctuations of the sky background emission overwhelm the WVR dynamic range and degrade the WVR sensitivity.","abstract_html":"Ground-based interferometric observations are severely affected by atmospheric conditions. Phase correction is a technique to obtain high quality data and achieve great scientific goals. For our acetic acid survey, a better phase correction technique can not only detect weaker transitions of large molecules, but also increase the map resolution of hot cores. Water vapor radiometers (WVRs) are designed to improve the technique by observing tropospheric water vapor along the lines of sight of interferometers. We have numerically demonstrated the importance of phase correction for interferometric observations and examined the water vapor phase correction technique. Furthermore, we have built two WVR prototypes with new calibration, thermal regulation and backend systems. The WVR prototypes had been tested in a laboratory, on a roof and at the CARMA site to verify their performance. We conclude the WVR thermal stability and dynamic range are critical while the enormous and rapid fluctuations of the sky background emission overwhelm the WVR dynamic range and degrade the WVR sensitivity.","abstract_has_math":false,"creators":["Shiao, Yu-Shao"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Astronomy","degree_department":null,"school":null,"contributors":["Leslie Looney"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-07-22T22:26:24Z","subjects":["Physics, Astronomy and Astrophysics"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI3337928"],"render_values":[{"text":"(MiAaPQ)AAI3337928","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/85187","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Leslie Looney"]},{"key":"dc:creator","label":"Author","values":["Shiao, Yu-Shao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008","2015-09-25T22:35:38Z","10000-01-01"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Astronomy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics, Astronomy and Astrophysics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/85187","(MiAaPQ)AAI3337928"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Ground-based interferometric observations are severely affected by atmospheric conditions. Phase correction is a technique to obtain high quality data and achieve great scientific goals. For our acetic acid survey, a better phase correction technique can not only detect weaker transitions of large molecules, but also increase the map resolution of hot cores. Water vapor radiometers (WVRs) are designed to improve the technique by observing tropospheric water vapor along the lines of sight of interferometers. We have numerically demonstrated the importance of phase correction for interferometric observations and examined the water vapor phase correction technique. Furthermore, we have built two WVR prototypes with new calibration, thermal regulation and backend systems. The WVR prototypes had been tested in a laboratory, on a roof and at the CARMA site to verify their performance. We conclude the WVR thermal stability and dynamic range are critical while the enormous and rapid fluctuations of the sky background emission overwhelm the WVR dynamic range and degrade the WVR sensitivity.","Made available in DSpace on 2015-09-25T22:35:38Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3337928.pdf: 6482279 bytes, checksum: 0f901fd91d813d2e134e847ce0a08caa (MD5) Previous issue date: 2008","Embargo set by: Seth Robbins for item 86468 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","130 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2008."]},{"key":"dc:title","label":"Title","values":["High Resolution Acetic Acid Survey and Water Vapor Radiometer"]}]}],"canonical_facts":{"dc:contributor":["Leslie Looney"],"dc:creator":["Shiao, Yu-Shao"],"dc:date":["2008","2015-09-25T22:35:38Z","10000-01-01"],"dc:description":["Ground-based interferometric observations are severely affected by atmospheric conditions. Phase correction is a technique to obtain high quality data and achieve great scientific goals. For our acetic acid survey, a better phase correction technique can not only detect weaker transitions of large molecules, but also increase the map resolution of hot cores. Water vapor radiometers (WVRs) are designed to improve the technique by observing tropospheric water vapor along the lines of sight of interferometers. We have numerically demonstrated the importance of phase correction for interferometric observations and examined the water vapor phase correction technique. Furthermore, we have built two WVR prototypes with new calibration, thermal regulation and backend systems. The WVR prototypes had been tested in a laboratory, on a roof and at the CARMA site to verify their performance. We conclude the WVR thermal stability and dynamic range are critical while the enormous and rapid fluctuations of the sky background emission overwhelm the WVR dynamic range and degrade the WVR sensitivity.","Made available in DSpace on 2015-09-25T22:35:38Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3337928.pdf: 6482279 bytes, checksum: 0f901fd91d813d2e134e847ce0a08caa (MD5) Previous issue date: 2008","Embargo set by: Seth Robbins for item 86468 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","130 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2008."],"dc:identifier":["http://hdl.handle.net/2142/85187","(MiAaPQ)AAI3337928"],"dc:language":["eng"],"dc:subject":["Physics, Astronomy and Astrophysics"],"dc:title":["High Resolution Acetic Acid Survey and Water Vapor Radiometer"],"dc:type":["text"],"thesis:degree_discipline":["Astronomy"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:24Z"}