{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/84016"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/84016","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Design, Fabrication, and Test of Chaotic Micromixers, Hydrogel Microvalves and pH Regulation Systems","abstract":"In the last part of the thesis, two integrated microsystems designed to provide self regulation of pH in bioassays are demonstrated. The first system is based on the counterflow microdialysis principle, whereas the second system involves direct addition of an acidic or basic buffer solution into a sample solution. In both systems, a hydrogel component is used as a pH sensor, controller, and valve, simultaneously. Oscillatory modulation of the flow was achieved, and the feasibility of autonomous control of pH in microsystems has been demonstrated.","abstract_html":"In the last part of the thesis, two integrated microsystems designed to provide self regulation of pH in bioassays are demonstrated. The first system is based on the counterflow microdialysis principle, whereas the second system involves direct addition of an acidic or basic buffer solution into a sample solution. In both systems, a hydrogel component is used as a pH sensor, controller, and valve, simultaneously. Oscillatory modulation of the flow was achieved, and the feasibility of autonomous control of pH in microsystems has been demonstrated.","abstract_has_math":false,"creators":["Liu, Hui"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["David J. Beebe"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-25T21:13:10Z","date_published":"2015-09-25T21:13:10Z","updated_at":"2026-07-22T22:26:22Z","subjects":["Engineering, Mechanical"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI9996655"],"render_values":[{"text":"(MiAaPQ)AAI9996655","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/84016","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["David J. Beebe"]},{"key":"dc:creator","label":"Author","values":["Liu, Hui"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-25T21:13:10Z","10000-01-01","2001"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/84016","(MiAaPQ)AAI9996655"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In the last part of the thesis, two integrated microsystems designed to provide self regulation of pH in bioassays are demonstrated. The first system is based on the counterflow microdialysis principle, whereas the second system involves direct addition of an acidic or basic buffer solution into a sample solution. In both systems, a hydrogel component is used as a pH sensor, controller, and valve, simultaneously. Oscillatory modulation of the flow was achieved, and the feasibility of autonomous control of pH in microsystems has been demonstrated.","Made available in DSpace on 2015-09-25T21:13:10Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 9996655.pdf: 7432391 bytes, checksum: f1310238f7e5b32725708b3709735ffd (MD5) Previous issue date: 2001","Embargo set by: Seth Robbins for item 85297 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","143 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2001."]},{"key":"dc:title","label":"Title","values":["Design, Fabrication, and Test of Chaotic Micromixers, Hydrogel Microvalves and pH Regulation Systems"]}]}],"canonical_facts":{"dc:contributor":["David J. Beebe"],"dc:creator":["Liu, Hui"],"dc:date":["2015-09-25T21:13:10Z","10000-01-01","2001"],"dc:description":["In the last part of the thesis, two integrated microsystems designed to provide self regulation of pH in bioassays are demonstrated. The first system is based on the counterflow microdialysis principle, whereas the second system involves direct addition of an acidic or basic buffer solution into a sample solution. In both systems, a hydrogel component is used as a pH sensor, controller, and valve, simultaneously. Oscillatory modulation of the flow was achieved, and the feasibility of autonomous control of pH in microsystems has been demonstrated.","Made available in DSpace on 2015-09-25T21:13:10Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 9996655.pdf: 7432391 bytes, checksum: f1310238f7e5b32725708b3709735ffd (MD5) Previous issue date: 2001","Embargo set by: Seth Robbins for item 85297 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","143 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2001."],"dc:identifier":["http://hdl.handle.net/2142/84016","(MiAaPQ)AAI9996655"],"dc:language":["eng"],"dc:subject":["Engineering, Mechanical"],"dc:title":["Design, Fabrication, and Test of Chaotic Micromixers, Hydrogel Microvalves and pH Regulation Systems"],"dc:type":["text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:22Z"}