{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/83974"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/83974","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Development of a Transient System Model of Mobile Air-Conditioning Systems","abstract":"An important part of the system model is calculating the refrigerant properties correctly. We developed refrigerant property routines to the calculate equilibrium thermodynamic properties in the liquid, vapor, two-phase liquid-vapor, and supercritical region using the Modified-Benedict-Webb-Rubin equation of state. Our property routines accurately solve for a given output property for applicable combinations of input properties. They also accurately predict whether the refrigerant is in the single-phase or two-phase region. The property routines agree extremely well with the experimental data found in the literature.","abstract_html":"An important part of the system model is calculating the refrigerant properties correctly. We developed refrigerant property routines to the calculate equilibrium thermodynamic properties in the liquid, vapor, two-phase liquid-vapor, and supercritical region using the Modified-Benedict-Webb-Rubin equation of state. Our property routines accurately solve for a given output property for applicable combinations of input properties. They also accurately predict whether the refrigerant is in the single-phase or two-phase region. The property routines agree extremely well with the experimental data found in the literature.","abstract_has_math":false,"creators":["Hemami, Tara Lynn"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Dunn, W.E."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-25T21:12:59Z","date_published":"2015-09-25T21:12:59Z","updated_at":"2026-07-22T22:26:22Z","subjects":["Engineering, Automotive"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI9912261"],"render_values":[{"text":"(MiAaPQ)AAI9912261","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/83974","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dunn, W.E."]},{"key":"dc:creator","label":"Author","values":["Hemami, Tara Lynn"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-25T21:12:59Z","10000-01-01","1998"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Automotive"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/83974","(MiAaPQ)AAI9912261"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["An important part of the system model is calculating the refrigerant properties correctly. We developed refrigerant property routines to the calculate equilibrium thermodynamic properties in the liquid, vapor, two-phase liquid-vapor, and supercritical region using the Modified-Benedict-Webb-Rubin equation of state. Our property routines accurately solve for a given output property for applicable combinations of input properties. They also accurately predict whether the refrigerant is in the single-phase or two-phase region. The property routines agree extremely well with the experimental data found in the literature.","Made available in DSpace on 2015-09-25T21:12:59Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 9912261.pdf: 10849769 bytes, checksum: b8e2cb90024fd736657d88b92abb69f3 (MD5) Previous issue date: 1998","Embargo set by: Seth Robbins for item 85255 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","237 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 1998."]},{"key":"dc:title","label":"Title","values":["Development of a Transient System Model of Mobile Air-Conditioning Systems"]}]}],"canonical_facts":{"dc:contributor":["Dunn, W.E."],"dc:creator":["Hemami, Tara Lynn"],"dc:date":["2015-09-25T21:12:59Z","10000-01-01","1998"],"dc:description":["An important part of the system model is calculating the refrigerant properties correctly. We developed refrigerant property routines to the calculate equilibrium thermodynamic properties in the liquid, vapor, two-phase liquid-vapor, and supercritical region using the Modified-Benedict-Webb-Rubin equation of state. Our property routines accurately solve for a given output property for applicable combinations of input properties. They also accurately predict whether the refrigerant is in the single-phase or two-phase region. The property routines agree extremely well with the experimental data found in the literature.","Made available in DSpace on 2015-09-25T21:12:59Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 9912261.pdf: 10849769 bytes, checksum: b8e2cb90024fd736657d88b92abb69f3 (MD5) Previous issue date: 1998","Embargo set by: Seth Robbins for item 85255 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","237 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 1998."],"dc:identifier":["http://hdl.handle.net/2142/83974","(MiAaPQ)AAI9912261"],"dc:language":["eng"],"dc:subject":["Engineering, Automotive"],"dc:title":["Development of a Transient System Model of Mobile Air-Conditioning Systems"],"dc:type":["text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:22Z"}