{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/83944"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/83944","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Scanning Probe Microscopy of Biomaterials and Nanoscale Biomechanics","abstract":"Since its invention, operation of AFM in liquid for imaging soft biomaterials has been hindered by a low quality factor caused by large drag forces on the cantilever. Utilizing the small dimensions of a nanoneedle, the new method presented in this dissertation resolves the complications by keeping the cantilever outside of the liquid and using a nanoneedle attached to the AFM probe as the sensing element in liquid. It was shown that this method in liquid maintained the harmonic dynamic characteristics of the cantilever similar to that in air and had an intrinsic high quality factor. The performance of the new method is demonstrated through imaging single collagen fibrils in liquid as well as the extremely soft membrane of living cells under physiological conditions.","abstract_html":"Since its invention, operation of AFM in liquid for imaging soft biomaterials has been hindered by a low quality factor caused by large drag forces on the cantilever. Utilizing the small dimensions of a nanoneedle, the new method presented in this dissertation resolves the complications by keeping the cantilever outside of the liquid and using a nanoneedle attached to the AFM probe as the sensing element in liquid. It was shown that this method in liquid maintained the harmonic dynamic characteristics of the cantilever similar to that in air and had an intrinsic high quality factor. The performance of the new method is demonstrated through imaging single collagen fibrils in liquid as well as the extremely soft membrane of living cells under physiological conditions.","abstract_has_math":false,"creators":["Jolandan, Majid Minary"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Yu, Min-Feng"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-25T21:12:48Z","date_published":"2015-09-25T21:12:48Z","updated_at":"2026-07-22T22:26:22Z","subjects":["Biophysics, Biomechanics"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI3455832"],"render_values":[{"text":"(MiAaPQ)AAI3455832","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/83944","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yu, Min-Feng"]},{"key":"dc:creator","label":"Author","values":["Jolandan, Majid Minary"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-25T21:12:48Z","10000-01-01","2010"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biophysics, Biomechanics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/83944","(MiAaPQ)AAI3455832"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Since its invention, operation of AFM in liquid for imaging soft biomaterials has been hindered by a low quality factor caused by large drag forces on the cantilever. Utilizing the small dimensions of a nanoneedle, the new method presented in this dissertation resolves the complications by keeping the cantilever outside of the liquid and using a nanoneedle attached to the AFM probe as the sensing element in liquid. It was shown that this method in liquid maintained the harmonic dynamic characteristics of the cantilever similar to that in air and had an intrinsic high quality factor. The performance of the new method is demonstrated through imaging single collagen fibrils in liquid as well as the extremely soft membrane of living cells under physiological conditions.","Made available in DSpace on 2015-09-25T21:12:48Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3455832.pdf: 4888006 bytes, checksum: 0aff6586633ed5baaf224d1a6204c7ad (MD5) Previous issue date: 2010","Embargo set by: Seth Robbins for item 85225 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","126 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2010."]},{"key":"dc:title","label":"Title","values":["Scanning Probe Microscopy of Biomaterials and Nanoscale Biomechanics"]}]}],"canonical_facts":{"dc:contributor":["Yu, Min-Feng"],"dc:creator":["Jolandan, Majid Minary"],"dc:date":["2015-09-25T21:12:48Z","10000-01-01","2010"],"dc:description":["Since its invention, operation of AFM in liquid for imaging soft biomaterials has been hindered by a low quality factor caused by large drag forces on the cantilever. Utilizing the small dimensions of a nanoneedle, the new method presented in this dissertation resolves the complications by keeping the cantilever outside of the liquid and using a nanoneedle attached to the AFM probe as the sensing element in liquid. It was shown that this method in liquid maintained the harmonic dynamic characteristics of the cantilever similar to that in air and had an intrinsic high quality factor. The performance of the new method is demonstrated through imaging single collagen fibrils in liquid as well as the extremely soft membrane of living cells under physiological conditions.","Made available in DSpace on 2015-09-25T21:12:48Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3455832.pdf: 4888006 bytes, checksum: 0aff6586633ed5baaf224d1a6204c7ad (MD5) Previous issue date: 2010","Embargo set by: Seth Robbins for item 85225 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","126 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2010."],"dc:identifier":["http://hdl.handle.net/2142/83944","(MiAaPQ)AAI3455832"],"dc:language":["eng"],"dc:subject":["Biophysics, Biomechanics"],"dc:title":["Scanning Probe Microscopy of Biomaterials and Nanoscale Biomechanics"],"dc:type":["text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:22Z"}