{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/83910"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/83910","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Fouling of Aluminum Oxide Microfiltration Membranes by Semi-Synthetic Metal Working Fluids","abstract":"The modeled membrane fouling mechanisms were validated through the reformulation of a semi-synthetic MWF designed to have greater microemulsion stability. It was experimentally verified that the new fluid did not see significant aggregation. Accordingly this fluid did not show evidence of significant flux decline. Functionality tests showed no difference in cooling and lubrication between the reformulated fluid and a commercial semi-synthetic MWF.","abstract_html":"The modeled membrane fouling mechanisms were validated through the reformulation of a semi-synthetic MWF designed to have greater microemulsion stability. It was experimentally verified that the new fluid did not see significant aggregation. Accordingly this fluid did not show evidence of significant flux decline. Functionality tests showed no difference in cooling and lubrication between the reformulated fluid and a commercial semi-synthetic MWF.","abstract_has_math":false,"creators":["Wentz, John"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Kapoor, Shiv G.","DeVor, Richard E."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-25T21:12:41Z","date_published":"2015-09-25T21:12:41Z","updated_at":"2026-07-22T22:26:22Z","subjects":["Engineering, Mechanical"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI3314936"],"render_values":[{"text":"(MiAaPQ)AAI3314936","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/83910","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kapoor, Shiv G.","DeVor, Richard E."]},{"key":"dc:creator","label":"Author","values":["Wentz, John"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-25T21:12:41Z","10000-01-01","2008"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/83910","(MiAaPQ)AAI3314936"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The modeled membrane fouling mechanisms were validated through the reformulation of a semi-synthetic MWF designed to have greater microemulsion stability. It was experimentally verified that the new fluid did not see significant aggregation. Accordingly this fluid did not show evidence of significant flux decline. Functionality tests showed no difference in cooling and lubrication between the reformulated fluid and a commercial semi-synthetic MWF.","Made available in DSpace on 2015-09-25T21:12:41Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3314936.pdf: 5974876 bytes, checksum: 0b3489466ed1d4fea34db2dec02bd65d (MD5) Previous issue date: 2008","Embargo set by: Seth Robbins for item 85191 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","213 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2008."]},{"key":"dc:title","label":"Title","values":["Fouling of Aluminum Oxide Microfiltration Membranes by Semi-Synthetic Metal Working Fluids"]}]}],"canonical_facts":{"dc:contributor":["Kapoor, Shiv G.","DeVor, Richard E."],"dc:creator":["Wentz, John"],"dc:date":["2015-09-25T21:12:41Z","10000-01-01","2008"],"dc:description":["The modeled membrane fouling mechanisms were validated through the reformulation of a semi-synthetic MWF designed to have greater microemulsion stability. It was experimentally verified that the new fluid did not see significant aggregation. Accordingly this fluid did not show evidence of significant flux decline. Functionality tests showed no difference in cooling and lubrication between the reformulated fluid and a commercial semi-synthetic MWF.","Made available in DSpace on 2015-09-25T21:12:41Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3314936.pdf: 5974876 bytes, checksum: 0b3489466ed1d4fea34db2dec02bd65d (MD5) Previous issue date: 2008","Embargo set by: Seth Robbins for item 85191 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","213 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2008."],"dc:identifier":["http://hdl.handle.net/2142/83910","(MiAaPQ)AAI3314936"],"dc:language":["eng"],"dc:subject":["Engineering, Mechanical"],"dc:title":["Fouling of Aluminum Oxide Microfiltration Membranes by Semi-Synthetic Metal Working Fluids"],"dc:type":["text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:22Z"}