{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/83459"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/83459","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"A Design Approach for Seismic Retrofit of Circular Bridge Columns With Lap Splices","abstract":"A careful examination of the cross section of the only column that was pulled to failure during the field tests carried out in this study suggested that the cracking pattern in the section was different from that assumed failure mechanism in the design method that was used. That was presumed to be the result of the offset orientation of the bars in the lap splice. However, due to irregularities in the reinforcement details for the field columns the correlation was not obvious. Therefore, a laboratory investigation was undertaken in order to study the optimal amount of lateral confinement necessary to avoid a lap splice failure, the influence of the bar orientation in the retrofitting of the columns, and to assess the different retrofitting techniques. Eight half size models were built with characteristics similar to the field columns, #11 bar sizes and thirty diameter (1.09 m (43 in.)) lap splice lengths, in order to be able to correlate the laboratory results directly with field columns results. To keep the number of the parameters to a minimum all columns were designed with exactly the same cross section. Meanwhile the amount and type of confinement was varied.","abstract_html":"A careful examination of the cross section of the only column that was pulled to failure during the field tests carried out in this study suggested that the cracking pattern in the section was different from that assumed failure mechanism in the design method that was used. That was presumed to be the result of the offset orientation of the bars in the lap splice. However, due to irregularities in the reinforcement details for the field columns the correlation was not obvious. Therefore, a laboratory investigation was undertaken in order to study the optimal amount of lateral confinement necessary to avoid a lap splice failure, the influence of the bar orientation in the retrofitting of the columns, and to assess the different retrofitting techniques. Eight half size models were built with characteristics similar to the field columns, #11 bar sizes and thirty diameter (1.09 m (43 in.)) lap splice lengths, in order to be able to correlate the laboratory results directly with field columns results. To keep the number of the parameters to a minimum all columns were designed with exactly the same cross section. Meanwhile the amount and type of confinement was varied.","abstract_has_math":false,"creators":["Shkurti, Fatjon Pineo"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":["Gamble, William L."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-25T21:05:02Z","date_published":"2015-09-25T21:05:02Z","updated_at":"2026-07-22T22:26:21Z","subjects":["Applied Mechanics"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI9904586"],"render_values":[{"text":"(MiAaPQ)AAI9904586","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/83459","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gamble, William L."]},{"key":"dc:creator","label":"Author","values":["Shkurti, Fatjon Pineo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-25T21:05:02Z","10000-01-01","1998"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Applied Mechanics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/83459","(MiAaPQ)AAI9904586"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A careful examination of the cross section of the only column that was pulled to failure during the field tests carried out in this study suggested that the cracking pattern in the section was different from that assumed failure mechanism in the design method that was used. That was presumed to be the result of the offset orientation of the bars in the lap splice. However, due to irregularities in the reinforcement details for the field columns the correlation was not obvious. Therefore, a laboratory investigation was undertaken in order to study the optimal amount of lateral confinement necessary to avoid a lap splice failure, the influence of the bar orientation in the retrofitting of the columns, and to assess the different retrofitting techniques. Eight half size models were built with characteristics similar to the field columns, #11 bar sizes and thirty diameter (1.09 m (43 in.)) lap splice lengths, in order to be able to correlate the laboratory results directly with field columns results. To keep the number of the parameters to a minimum all columns were designed with exactly the same cross section. Meanwhile the amount and type of confinement was varied.","Made available in DSpace on 2015-09-25T21:05:02Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 9904586.pdf: 12243520 bytes, checksum: 5d31e15eeb9c97eabda239149ffc320c (MD5) Previous issue date: 1998","Embargo set by: Seth Robbins for item 84740 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","298 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 1998."]},{"key":"dc:title","label":"Title","values":["A Design Approach for Seismic Retrofit of Circular Bridge Columns With Lap Splices"]}]}],"canonical_facts":{"dc:contributor":["Gamble, William L."],"dc:creator":["Shkurti, Fatjon Pineo"],"dc:date":["2015-09-25T21:05:02Z","10000-01-01","1998"],"dc:description":["A careful examination of the cross section of the only column that was pulled to failure during the field tests carried out in this study suggested that the cracking pattern in the section was different from that assumed failure mechanism in the design method that was used. That was presumed to be the result of the offset orientation of the bars in the lap splice. However, due to irregularities in the reinforcement details for the field columns the correlation was not obvious. Therefore, a laboratory investigation was undertaken in order to study the optimal amount of lateral confinement necessary to avoid a lap splice failure, the influence of the bar orientation in the retrofitting of the columns, and to assess the different retrofitting techniques. Eight half size models were built with characteristics similar to the field columns, #11 bar sizes and thirty diameter (1.09 m (43 in.)) lap splice lengths, in order to be able to correlate the laboratory results directly with field columns results. To keep the number of the parameters to a minimum all columns were designed with exactly the same cross section. Meanwhile the amount and type of confinement was varied.","Made available in DSpace on 2015-09-25T21:05:02Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 9904586.pdf: 12243520 bytes, checksum: 5d31e15eeb9c97eabda239149ffc320c (MD5) Previous issue date: 1998","Embargo set by: Seth Robbins for item 84740 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","298 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 1998."],"dc:identifier":["http://hdl.handle.net/2142/83459","(MiAaPQ)AAI9904586"],"dc:language":["eng"],"dc:subject":["Applied Mechanics"],"dc:title":["A Design Approach for Seismic Retrofit of Circular Bridge Columns With Lap Splices"],"dc:type":["text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:21Z"}