{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/83155"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/83155","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Structural Damage Detection and Assessment From Spatially Sparse and Noise -Polluted Modal Response","abstract":"A global damage detection and assessment algorithm is developed based on a parameter estimation method using the measured modal response of a structure. Damage is characterized by a reduction in a constitutive property of a parameterized finite-element model of the structure between two discrete time inferences. A parameter group-updating scheme is proposed to localize damage in a structural system taking into account the multiplicity of parameter estimation solutions arising from using spatially sparse and noise-polluted data. A unified approach, based on the random starting point scheme and the optimum sensitivity method, for determining solution clustering is used to find multiple solutions and to assess the sensitivity of parameter estimates to noise. The best solution cluster, indicated by the lowest objective, is used as a basis for group subdivision at each level of the damage localization process. The statistical distribution of the element parameters of the damaged and the associated baseline structure is used to assess the severity of damage at the potential damage sites. The proposed damage detection and assessment procedure is tested with a certain set of simulation case studies using a planar bridge truss and a three-dimensional tower truss as the model problems.","abstract_html":"A global damage detection and assessment algorithm is developed based on a parameter estimation method using the measured modal response of a structure. Damage is characterized by a reduction in a constitutive property of a parameterized finite-element model of the structure between two discrete time inferences. A parameter group-updating scheme is proposed to localize damage in a structural system taking into account the multiplicity of parameter estimation solutions arising from using spatially sparse and noise-polluted data. A unified approach, based on the random starting point scheme and the optimum sensitivity method, for determining solution clustering is used to find multiple solutions and to assess the sensitivity of parameter estimates to noise. The best solution cluster, indicated by the lowest objective, is used as a basis for group subdivision at each level of the damage localization process. The statistical distribution of the element parameters of the damaged and the associated baseline structure is used to assess the severity of damage at the potential damage sites. The proposed damage detection and assessment procedure is tested with a certain set of simulation case studies using a planar bridge truss and a three-dimensional tower truss as the model problems.","abstract_has_math":false,"creators":["Pothisiri, Thanyawat"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":["Hjelmstad, Keith D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2001,"date_issued":"2001","date_published":"2001","updated_at":"2026-07-22T22:26:20Z","subjects":["Engineering, Civil"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI3017184"],"render_values":[{"text":"(MiAaPQ)AAI3017184","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/83155","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hjelmstad, Keith D."]},{"key":"dc:creator","label":"Author","values":["Pothisiri, Thanyawat"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2001","2015-09-25T21:03:07Z","10000-01-01"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Civil"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/83155","(MiAaPQ)AAI3017184"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A global damage detection and assessment algorithm is developed based on a parameter estimation method using the measured modal response of a structure. Damage is characterized by a reduction in a constitutive property of a parameterized finite-element model of the structure between two discrete time inferences. A parameter group-updating scheme is proposed to localize damage in a structural system taking into account the multiplicity of parameter estimation solutions arising from using spatially sparse and noise-polluted data. A unified approach, based on the random starting point scheme and the optimum sensitivity method, for determining solution clustering is used to find multiple solutions and to assess the sensitivity of parameter estimates to noise. The best solution cluster, indicated by the lowest objective, is used as a basis for group subdivision at each level of the damage localization process. The statistical distribution of the element parameters of the damaged and the associated baseline structure is used to assess the severity of damage at the potential damage sites. The proposed damage detection and assessment procedure is tested with a certain set of simulation case studies using a planar bridge truss and a three-dimensional tower truss as the model problems.","Made available in DSpace on 2015-09-25T21:03:07Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3017184.pdf: 7144330 bytes, checksum: b7237985559abb4b6552eeb8e59f149b (MD5) Previous issue date: 2001","Embargo set by: Seth Robbins for item 84436 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","126 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2001."]},{"key":"dc:title","label":"Title","values":["Structural Damage Detection and Assessment From Spatially Sparse and Noise -Polluted Modal Response"]}]}],"canonical_facts":{"dc:contributor":["Hjelmstad, Keith D."],"dc:creator":["Pothisiri, Thanyawat"],"dc:date":["2001","2015-09-25T21:03:07Z","10000-01-01"],"dc:description":["A global damage detection and assessment algorithm is developed based on a parameter estimation method using the measured modal response of a structure. Damage is characterized by a reduction in a constitutive property of a parameterized finite-element model of the structure between two discrete time inferences. A parameter group-updating scheme is proposed to localize damage in a structural system taking into account the multiplicity of parameter estimation solutions arising from using spatially sparse and noise-polluted data. A unified approach, based on the random starting point scheme and the optimum sensitivity method, for determining solution clustering is used to find multiple solutions and to assess the sensitivity of parameter estimates to noise. The best solution cluster, indicated by the lowest objective, is used as a basis for group subdivision at each level of the damage localization process. The statistical distribution of the element parameters of the damaged and the associated baseline structure is used to assess the severity of damage at the potential damage sites. The proposed damage detection and assessment procedure is tested with a certain set of simulation case studies using a planar bridge truss and a three-dimensional tower truss as the model problems.","Made available in DSpace on 2015-09-25T21:03:07Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3017184.pdf: 7144330 bytes, checksum: b7237985559abb4b6552eeb8e59f149b (MD5) Previous issue date: 2001","Embargo set by: Seth Robbins for item 84436 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","126 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2001."],"dc:identifier":["http://hdl.handle.net/2142/83155","(MiAaPQ)AAI3017184"],"dc:language":["eng"],"dc:subject":["Engineering, Civil"],"dc:title":["Structural Damage Detection and Assessment From Spatially Sparse and Noise -Polluted Modal Response"],"dc:type":["text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:20Z"}