{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/82485"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/82485","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Transport-Kinetic Processes and Surface Chemistry in Biosensor Design","abstract":"\"Finally, sample mixing is examined as a potential method to improve the performance of microfluidic biosensors. We attempt to mix sections of the sample solution where the analyte concentration is high with other sections where it is low, and thereby reduce the sensor response time when the detection kinetics are diffusion-limited. A serpentine micromixer, originally designed to mix two fluids in bulk solution via \"\"chaotic advection,\"\" is used to mix the sample as it passes through a surface plasmon resonance biosensor. These experiments indicate that such \"\"solution-based\"\" mixing strategies can be effective in microfluidic biosensors.\"","abstract_html":"&quot;Finally, sample mixing is examined as a potential method to improve the performance of microfluidic biosensors. We attempt to mix sections of the sample solution where the analyte concentration is high with other sections where it is low, and thereby reduce the sensor response time when the detection kinetics are diffusion-limited. A serpentine micromixer, originally designed to mix two fluids in bulk solution via &quot;&quot;chaotic advection,&quot;&quot; is used to mix the sample as it passes through a surface plasmon resonance biosensor. These experiments indicate that such &quot;&quot;solution-based&quot;&quot; mixing strategies can be effective in microfluidic biosensors.&quot;","abstract_has_math":false,"creators":["Vijayendran, Ravi Albert"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Leckband, Deborah E."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-25T20:44:19Z","date_published":"2015-09-25T20:44:19Z","updated_at":"2026-07-22T22:26:18Z","subjects":["Engineering, Biomedical"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI9996698"],"render_values":[{"text":"(MiAaPQ)AAI9996698","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/82485","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Leckband, Deborah E."]},{"key":"dc:creator","label":"Author","values":["Vijayendran, Ravi Albert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-25T20:44:19Z","10000-01-01","2001"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/82485","(MiAaPQ)AAI9996698"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["\"Finally, sample mixing is examined as a potential method to improve the performance of microfluidic biosensors. We attempt to mix sections of the sample solution where the analyte concentration is high with other sections where it is low, and thereby reduce the sensor response time when the detection kinetics are diffusion-limited. A serpentine micromixer, originally designed to mix two fluids in bulk solution via \"\"chaotic advection,\"\" is used to mix the sample as it passes through a surface plasmon resonance biosensor. These experiments indicate that such \"\"solution-based\"\" mixing strategies can be effective in microfluidic biosensors.\"","Made available in DSpace on 2015-09-25T20:44:19Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 9996698.pdf: 5362062 bytes, checksum: c9eaffd59cfd2b03fc81d4f4083abbd5 (MD5) Previous issue date: 2001","Embargo set by: Seth Robbins for item 83766 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","124 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2001."]},{"key":"dc:title","label":"Title","values":["Transport-Kinetic Processes and Surface Chemistry in Biosensor Design"]}]}],"canonical_facts":{"dc:contributor":["Leckband, Deborah E."],"dc:creator":["Vijayendran, Ravi Albert"],"dc:date":["2015-09-25T20:44:19Z","10000-01-01","2001"],"dc:description":["\"Finally, sample mixing is examined as a potential method to improve the performance of microfluidic biosensors. We attempt to mix sections of the sample solution where the analyte concentration is high with other sections where it is low, and thereby reduce the sensor response time when the detection kinetics are diffusion-limited. A serpentine micromixer, originally designed to mix two fluids in bulk solution via \"\"chaotic advection,\"\" is used to mix the sample as it passes through a surface plasmon resonance biosensor. These experiments indicate that such \"\"solution-based\"\" mixing strategies can be effective in microfluidic biosensors.\"","Made available in DSpace on 2015-09-25T20:44:19Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 9996698.pdf: 5362062 bytes, checksum: c9eaffd59cfd2b03fc81d4f4083abbd5 (MD5) Previous issue date: 2001","Embargo set by: Seth Robbins for item 83766 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","124 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2001."],"dc:identifier":["http://hdl.handle.net/2142/82485","(MiAaPQ)AAI9996698"],"dc:language":["eng"],"dc:subject":["Engineering, Biomedical"],"dc:title":["Transport-Kinetic Processes and Surface Chemistry in Biosensor Design"],"dc:type":["text"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:18Z"}