{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/82389"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/82389","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Microfluidics for Biomolecular Studies","abstract":"Large-scale integrated microfluidic networks were designed and fabricated in order to carry out large combinatorial synthesis and screening. The microfluidic devices contained a series of small chambers with a total volume of one nanoliter to contain each of the combinations in the screening library. The library screen was carried out using a label-free sensor that was integrated into the microfluidic device. The sensor identified strongly binding ligands in a combinatorial screen of antibodies.","abstract_html":"Large-scale integrated microfluidic networks were designed and fabricated in order to carry out large combinatorial synthesis and screening. The microfluidic devices contained a series of small chambers with a total volume of one nanoliter to contain each of the combinations in the screening library. The library screen was carried out using a label-free sensor that was integrated into the microfluidic device. The sensor identified strongly binding ligands in a combinatorial screen of antibodies.","abstract_has_math":false,"creators":["Toepke, Michael W."],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Chemical and Biomolecular Engineering","degree_department":null,"school":null,"contributors":["Kenis, Paul J.A."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-25T20:43:28Z","date_published":"2015-09-25T20:43:28Z","updated_at":"2026-07-22T22:26:18Z","subjects":["Engineering, Chemical"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI3243012"],"render_values":[{"text":"(MiAaPQ)AAI3243012","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/82389","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kenis, Paul J.A."]},{"key":"dc:creator","label":"Author","values":["Toepke, Michael W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-25T20:43:28Z","10000-01-01","2006"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Biomolecular Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Chemical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/82389","(MiAaPQ)AAI3243012"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Large-scale integrated microfluidic networks were designed and fabricated in order to carry out large combinatorial synthesis and screening. The microfluidic devices contained a series of small chambers with a total volume of one nanoliter to contain each of the combinations in the screening library. The library screen was carried out using a label-free sensor that was integrated into the microfluidic device. The sensor identified strongly binding ligands in a combinatorial screen of antibodies.","Made available in DSpace on 2015-09-25T20:43:28Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3243012.pdf: 3517043 bytes, checksum: 72235458f8b7efc136e2a5f38b2df8a6 (MD5) Previous issue date: 2006","Embargo set by: Seth Robbins for item 83670 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","109 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2006."]},{"key":"dc:title","label":"Title","values":["Microfluidics for Biomolecular Studies"]}]}],"canonical_facts":{"dc:contributor":["Kenis, Paul J.A."],"dc:creator":["Toepke, Michael W."],"dc:date":["2015-09-25T20:43:28Z","10000-01-01","2006"],"dc:description":["Large-scale integrated microfluidic networks were designed and fabricated in order to carry out large combinatorial synthesis and screening. The microfluidic devices contained a series of small chambers with a total volume of one nanoliter to contain each of the combinations in the screening library. The library screen was carried out using a label-free sensor that was integrated into the microfluidic device. The sensor identified strongly binding ligands in a combinatorial screen of antibodies.","Made available in DSpace on 2015-09-25T20:43:28Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3243012.pdf: 3517043 bytes, checksum: 72235458f8b7efc136e2a5f38b2df8a6 (MD5) Previous issue date: 2006","Embargo set by: Seth Robbins for item 83670 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","109 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2006."],"dc:identifier":["http://hdl.handle.net/2142/82389","(MiAaPQ)AAI3243012"],"dc:language":["eng"],"dc:subject":["Engineering, Chemical"],"dc:title":["Microfluidics for Biomolecular Studies"],"dc:type":["text"],"thesis:degree_discipline":["Chemical and Biomolecular Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:18Z"}