{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/81353"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/81353","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Computational Framework for Assessing Voltage Security Using Energy Methods","abstract":"This thesis develops a theoretically sound and computationally practical set of tools for assessing and quantifying the voltage security of a power system in terms of an intuitive measure. This measure, called the maximum loading percentage (MLP), expresses the proximity of a system to serving the maximum amount of load it can furnish without experiencing a voltage collapse. When used in conjunction with the adaptive system reduction technique introduced in this research, an effective method of screening the system for areas of concern, and a new, improved method for locating alternative power flow solutions, the proposed measure quickly and accurately evaluates the voltage security of power systems, even those of large dimension. This work also introduces a technique for identifying the most effective controls for mitigating the effects of voltage collapse once it occurs. Finally, it advances power flow calculation methods by offering algorithms that improve the convergence properties of power flow engines in solving modern power system models. The proposed tools are applied to systems ranging in size from two to several thousand buses.","abstract_html":"This thesis develops a theoretically sound and computationally practical set of tools for assessing and quantifying the voltage security of a power system in terms of an intuitive measure. This measure, called the maximum loading percentage (MLP), expresses the proximity of a system to serving the maximum amount of load it can furnish without experiencing a voltage collapse. When used in conjunction with the adaptive system reduction technique introduced in this research, an effective method of screening the system for areas of concern, and a new, improved method for locating alternative power flow solutions, the proposed measure quickly and accurately evaluates the voltage security of power systems, even those of large dimension. This work also introduces a technique for identifying the most effective controls for mitigating the effects of voltage collapse once it occurs. Finally, it advances power flow calculation methods by offering algorithms that improve the convergence properties of power flow engines in solving modern power system models. The proposed tools are applied to systems ranging in size from two to several thousand buses.","abstract_has_math":false,"creators":["Klump, Raymond Peter"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Overbye, Thomas J."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-25T20:10:42Z","date_published":"2015-09-25T20:10:42Z","updated_at":"2026-07-22T22:26:16Z","subjects":["Engineering, Electronics and Electrical"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI9990048"],"render_values":[{"text":"(MiAaPQ)AAI9990048","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/81353","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Overbye, Thomas J."]},{"key":"dc:creator","label":"Author","values":["Klump, Raymond Peter"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-25T20:10:42Z","10000-01-01","2000"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Electronics and Electrical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/81353","(MiAaPQ)AAI9990048"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis develops a theoretically sound and computationally practical set of tools for assessing and quantifying the voltage security of a power system in terms of an intuitive measure. This measure, called the maximum loading percentage (MLP), expresses the proximity of a system to serving the maximum amount of load it can furnish without experiencing a voltage collapse. When used in conjunction with the adaptive system reduction technique introduced in this research, an effective method of screening the system for areas of concern, and a new, improved method for locating alternative power flow solutions, the proposed measure quickly and accurately evaluates the voltage security of power systems, even those of large dimension. This work also introduces a technique for identifying the most effective controls for mitigating the effects of voltage collapse once it occurs. Finally, it advances power flow calculation methods by offering algorithms that improve the convergence properties of power flow engines in solving modern power system models. The proposed tools are applied to systems ranging in size from two to several thousand buses.","Made available in DSpace on 2015-09-25T20:10:42Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 9990048.pdf: 7653805 bytes, checksum: a89e1ecc31490d24bb6e8b82035505bf (MD5) Previous issue date: 2000","Embargo set by: Seth Robbins for item 82634 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","174 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2000."]},{"key":"dc:title","label":"Title","values":["Computational Framework for Assessing Voltage Security Using Energy Methods"]}]}],"canonical_facts":{"dc:contributor":["Overbye, Thomas J."],"dc:creator":["Klump, Raymond Peter"],"dc:date":["2015-09-25T20:10:42Z","10000-01-01","2000"],"dc:description":["This thesis develops a theoretically sound and computationally practical set of tools for assessing and quantifying the voltage security of a power system in terms of an intuitive measure. This measure, called the maximum loading percentage (MLP), expresses the proximity of a system to serving the maximum amount of load it can furnish without experiencing a voltage collapse. When used in conjunction with the adaptive system reduction technique introduced in this research, an effective method of screening the system for areas of concern, and a new, improved method for locating alternative power flow solutions, the proposed measure quickly and accurately evaluates the voltage security of power systems, even those of large dimension. This work also introduces a technique for identifying the most effective controls for mitigating the effects of voltage collapse once it occurs. Finally, it advances power flow calculation methods by offering algorithms that improve the convergence properties of power flow engines in solving modern power system models. The proposed tools are applied to systems ranging in size from two to several thousand buses.","Made available in DSpace on 2015-09-25T20:10:42Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 9990048.pdf: 7653805 bytes, checksum: a89e1ecc31490d24bb6e8b82035505bf (MD5) Previous issue date: 2000","Embargo set by: Seth Robbins for item 82634 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","174 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2000."],"dc:identifier":["http://hdl.handle.net/2142/81353","(MiAaPQ)AAI9990048"],"dc:language":["eng"],"dc:subject":["Engineering, Electronics and Electrical"],"dc:title":["Computational Framework for Assessing Voltage Security Using Energy Methods"],"dc:type":["text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:16Z"}