{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/80854"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/80854","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Estimating the Medical Ultrasound in Vivo Power Spectrum","abstract":"This thesis considered the estimation of the in vivo power spectrum from the backscattered waveforms by finding the total attenuation along the propagation path. The total attenuation was estimated by assuming model for the scatterers (i.e., spherically symmetric Gaussian impedance distributions of unknown size) and then solving for the size and total attenuation simultaneously from the frequency dependence of the backscattered spectrum. The attenuation and scatterer size could be accurately and precisely estimated provided that sufficient frequency data was available. The accuracy and precision were significantly improved by increasing the range of frequencies used in the estimate. In addition, some improvement could be obtained by increasing the length of the window used to gate the backscattered RF echoes (i.e., samples in frequency domain independent). Although only applied to the estimation of scatterer size in this thesis, the estimation of the in vivo power spectrum using the developed methods could be applied to other tissue characterization procedures as well as estimating the temperature increase in the tissue from ultrasound exposures.","abstract_html":"This thesis considered the estimation of the in vivo power spectrum from the backscattered waveforms by finding the total attenuation along the propagation path. The total attenuation was estimated by assuming model for the scatterers (i.e., spherically symmetric Gaussian impedance distributions of unknown size) and then solving for the size and total attenuation simultaneously from the frequency dependence of the backscattered spectrum. The attenuation and scatterer size could be accurately and precisely estimated provided that sufficient frequency data was available. The accuracy and precision were significantly improved by increasing the range of frequencies used in the estimate. In addition, some improvement could be obtained by increasing the length of the window used to gate the backscattered RF echoes (i.e., samples in frequency domain independent). Although only applied to the estimation of scatterer size in this thesis, the estimation of the in vivo power spectrum using the developed methods could be applied to other tissue characterization procedures as well as estimating the temperature increase in the tissue from ultrasound exposures.","abstract_has_math":false,"creators":["Bigelow, Timothy Allen"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["William D. O'Brien, Jr"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-25T20:08:30Z","date_published":"2015-09-25T20:08:30Z","updated_at":"2026-07-22T22:26:15Z","subjects":["Health Sciences, Radiology"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI3130881"],"render_values":[{"text":"(MiAaPQ)AAI3130881","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/80854","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["William D. O'Brien, Jr"]},{"key":"dc:creator","label":"Author","values":["Bigelow, Timothy Allen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-25T20:08:30Z","10000-01-01","2004"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health Sciences, Radiology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/80854","(MiAaPQ)AAI3130881"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis considered the estimation of the in vivo power spectrum from the backscattered waveforms by finding the total attenuation along the propagation path. The total attenuation was estimated by assuming model for the scatterers (i.e., spherically symmetric Gaussian impedance distributions of unknown size) and then solving for the size and total attenuation simultaneously from the frequency dependence of the backscattered spectrum. The attenuation and scatterer size could be accurately and precisely estimated provided that sufficient frequency data was available. The accuracy and precision were significantly improved by increasing the range of frequencies used in the estimate. In addition, some improvement could be obtained by increasing the length of the window used to gate the backscattered RF echoes (i.e., samples in frequency domain independent). Although only applied to the estimation of scatterer size in this thesis, the estimation of the in vivo power spectrum using the developed methods could be applied to other tissue characterization procedures as well as estimating the temperature increase in the tissue from ultrasound exposures.","Made available in DSpace on 2015-09-25T20:08:30Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3130881.pdf: 7580236 bytes, checksum: 98f8deb50aeb0f0698ebf4b706823756 (MD5) Previous issue date: 2004","Embargo set by: Seth Robbins for item 82136 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","243 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2004."]},{"key":"dc:title","label":"Title","values":["Estimating the Medical Ultrasound in Vivo Power Spectrum"]}]}],"canonical_facts":{"dc:contributor":["William D. O'Brien, Jr"],"dc:creator":["Bigelow, Timothy Allen"],"dc:date":["2015-09-25T20:08:30Z","10000-01-01","2004"],"dc:description":["This thesis considered the estimation of the in vivo power spectrum from the backscattered waveforms by finding the total attenuation along the propagation path. The total attenuation was estimated by assuming model for the scatterers (i.e., spherically symmetric Gaussian impedance distributions of unknown size) and then solving for the size and total attenuation simultaneously from the frequency dependence of the backscattered spectrum. The attenuation and scatterer size could be accurately and precisely estimated provided that sufficient frequency data was available. The accuracy and precision were significantly improved by increasing the range of frequencies used in the estimate. In addition, some improvement could be obtained by increasing the length of the window used to gate the backscattered RF echoes (i.e., samples in frequency domain independent). Although only applied to the estimation of scatterer size in this thesis, the estimation of the in vivo power spectrum using the developed methods could be applied to other tissue characterization procedures as well as estimating the temperature increase in the tissue from ultrasound exposures.","Made available in DSpace on 2015-09-25T20:08:30Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3130881.pdf: 7580236 bytes, checksum: 98f8deb50aeb0f0698ebf4b706823756 (MD5) Previous issue date: 2004","Embargo set by: Seth Robbins for item 82136 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","243 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2004."],"dc:identifier":["http://hdl.handle.net/2142/80854","(MiAaPQ)AAI3130881"],"dc:language":["eng"],"dc:subject":["Health Sciences, Radiology"],"dc:title":["Estimating the Medical Ultrasound in Vivo Power Spectrum"],"dc:type":["text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:15Z"}