{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/80528"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/80528","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Measurement of Internal Movements of the Escherichia Coli Ribosome Using Forster Resonance Energy Transfer and Microsecond, Continuous -Flow Turbulent Mixing in Micro-Fabricated Devices","abstract":"The second half of this thesis is independent of the above. We present the design, construction and implementation of micro-fabricated, continuous-flow, turbulent mixing devices that can mix two or three fluids to complete homogeneity on the molecular scale in the microsecond range. The prototypical designs are compact, portable, simple to fabricate and consume smaller sample volumes than current technology. We characterize the turbulent mixing process in microfluidic channels with fluorescence intensity and lifetime imaging and show that both the dependence of mixing times and pressure drop on the flow velocity and Reynolds number agree well with theoretical expectations for turbulent pipe flow. The novelties in this work are: the new methods of fabrication which enable production of three-dimensional geometries in glass with micro-fabrication methods, the implementation of turbulent mixing and measurement at microsecond timescales and showing the ability to generalize theoretical expectations for turbulence in pipes with micrometer scale dimensions.","abstract_html":"The second half of this thesis is independent of the above. We present the design, construction and implementation of micro-fabricated, continuous-flow, turbulent mixing devices that can mix two or three fluids to complete homogeneity on the molecular scale in the microsecond range. The prototypical designs are compact, portable, simple to fabricate and consume smaller sample volumes than current technology. We characterize the turbulent mixing process in microfluidic channels with fluorescence intensity and lifetime imaging and show that both the dependence of mixing times and pressure drop on the flow velocity and Reynolds number agree well with theoretical expectations for turbulent pipe flow. The novelties in this work are: the new methods of fabrication which enable production of three-dimensional geometries in glass with micro-fabrication methods, the implementation of turbulent mixing and measurement at microsecond timescales and showing the ability to generalize theoretical expectations for turbulence in pipes with micrometer scale dimensions.","abstract_has_math":false,"creators":["Majumdar, Zigurts Krishna"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Clegg, Robert M."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-25T20:02:56Z","date_published":"2015-09-25T20:02:56Z","updated_at":"2026-07-22T22:26:14Z","subjects":["Biology, Molecular"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI3202138"],"render_values":[{"text":"(MiAaPQ)AAI3202138","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/80528","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Clegg, Robert M."]},{"key":"dc:creator","label":"Author","values":["Majumdar, Zigurts Krishna"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-25T20:02:56Z","10000-01-01","2005"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biology, Molecular"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/80528","(MiAaPQ)AAI3202138"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The second half of this thesis is independent of the above. We present the design, construction and implementation of micro-fabricated, continuous-flow, turbulent mixing devices that can mix two or three fluids to complete homogeneity on the molecular scale in the microsecond range. The prototypical designs are compact, portable, simple to fabricate and consume smaller sample volumes than current technology. We characterize the turbulent mixing process in microfluidic channels with fluorescence intensity and lifetime imaging and show that both the dependence of mixing times and pressure drop on the flow velocity and Reynolds number agree well with theoretical expectations for turbulent pipe flow. The novelties in this work are: the new methods of fabrication which enable production of three-dimensional geometries in glass with micro-fabrication methods, the implementation of turbulent mixing and measurement at microsecond timescales and showing the ability to generalize theoretical expectations for turbulence in pipes with micrometer scale dimensions.","Made available in DSpace on 2015-09-25T20:02:56Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3202138.pdf: 5455853 bytes, checksum: 145a8e1d835e910034c370181ac8ae30 (MD5) Previous issue date: 2005","Embargo set by: Seth Robbins for item 81810 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","193 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2005."]},{"key":"dc:title","label":"Title","values":["Measurement of Internal Movements of the Escherichia Coli Ribosome Using Forster Resonance Energy Transfer and Microsecond, Continuous -Flow Turbulent Mixing in Micro-Fabricated Devices"]}]}],"canonical_facts":{"dc:contributor":["Clegg, Robert M."],"dc:creator":["Majumdar, Zigurts Krishna"],"dc:date":["2015-09-25T20:02:56Z","10000-01-01","2005"],"dc:description":["The second half of this thesis is independent of the above. We present the design, construction and implementation of micro-fabricated, continuous-flow, turbulent mixing devices that can mix two or three fluids to complete homogeneity on the molecular scale in the microsecond range. The prototypical designs are compact, portable, simple to fabricate and consume smaller sample volumes than current technology. We characterize the turbulent mixing process in microfluidic channels with fluorescence intensity and lifetime imaging and show that both the dependence of mixing times and pressure drop on the flow velocity and Reynolds number agree well with theoretical expectations for turbulent pipe flow. The novelties in this work are: the new methods of fabrication which enable production of three-dimensional geometries in glass with micro-fabrication methods, the implementation of turbulent mixing and measurement at microsecond timescales and showing the ability to generalize theoretical expectations for turbulence in pipes with micrometer scale dimensions.","Made available in DSpace on 2015-09-25T20:02:56Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3202138.pdf: 5455853 bytes, checksum: 145a8e1d835e910034c370181ac8ae30 (MD5) Previous issue date: 2005","Embargo set by: Seth Robbins for item 81810 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","193 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2005."],"dc:identifier":["http://hdl.handle.net/2142/80528","(MiAaPQ)AAI3202138"],"dc:language":["eng"],"dc:subject":["Biology, Molecular"],"dc:title":["Measurement of Internal Movements of the Escherichia Coli Ribosome Using Forster Resonance Energy Transfer and Microsecond, Continuous -Flow Turbulent Mixing in Micro-Fabricated Devices"],"dc:type":["text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:14Z"}