{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/80464"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/80464","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Spatial Localization and Temporal Analysis of Optical Property Fluctuations by Multiplexed Near -Infrared Photon Density Waves in Turbid Media: In Vitro and in Vivo Studies","abstract":"Recently much attention has been given to the study of the processes in the human brain that lead to the changing of the optical parameters that characterize the tissue, measured by our frequency-domain instrumentation. These processes have been divided into two main categories with different time-scales. The slower one is mostly due to the fluctuations in the absorption coefficient caused by oxy- and deoxy-hemoglobin changes in the tissue. The temporal analysis of the signal resulting from this process is studied in detail, and I also introduce a time-series data analysis technique that has not been applied to this field before but was introduced in another area very recently. The faster time-scale process has been attributed to the electrochemical excitation of the individual neurons in the brain that have been observed to cause a change in the scattering coefficient of the tissue. This is the other primary parameter that is measured by our frequency domain instrument. However, before this work it has not been clear how to go about to better localize these smaller fluctuations. I present a novel idea for improving spatial localization of macroscopic optical parameter fluctuations, and study the characteristics of this optical probe design using analytical solutions to the diffusion equation and Monte Carlo simulations that more appropriately represent the volume of excitation of the cortex neurons.","abstract_html":"Recently much attention has been given to the study of the processes in the human brain that lead to the changing of the optical parameters that characterize the tissue, measured by our frequency-domain instrumentation. These processes have been divided into two main categories with different time-scales. The slower one is mostly due to the fluctuations in the absorption coefficient caused by oxy- and deoxy-hemoglobin changes in the tissue. The temporal analysis of the signal resulting from this process is studied in detail, and I also introduce a time-series data analysis technique that has not been applied to this field before but was introduced in another area very recently. The faster time-scale process has been attributed to the electrochemical excitation of the individual neurons in the brain that have been observed to cause a change in the scattering coefficient of the tissue. This is the other primary parameter that is measured by our frequency domain instrument. However, before this work it has not been clear how to go about to better localize these smaller fluctuations. I present a novel idea for improving spatial localization of macroscopic optical parameter fluctuations, and study the characteristics of this optical probe design using analytical solutions to the diffusion equation and Monte Carlo simulations that more appropriately represent the volume of excitation of the cortex neurons.","abstract_has_math":false,"creators":["Filiaci, Mattia Emidio"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Gratton, Enrico"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-25T20:02:35Z","date_published":"2015-09-25T20:02:35Z","updated_at":"2026-07-22T22:26:14Z","subjects":["Physics, Optics"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(MiAaPQ)AAI3017074"],"render_values":[{"text":"(MiAaPQ)AAI3017074","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/80464","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gratton, Enrico"]},{"key":"dc:creator","label":"Author","values":["Filiaci, Mattia Emidio"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-25T20:02:35Z","10000-01-01","2001"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics, Optics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/80464","(MiAaPQ)AAI3017074"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Recently much attention has been given to the study of the processes in the human brain that lead to the changing of the optical parameters that characterize the tissue, measured by our frequency-domain instrumentation. These processes have been divided into two main categories with different time-scales. The slower one is mostly due to the fluctuations in the absorption coefficient caused by oxy- and deoxy-hemoglobin changes in the tissue. The temporal analysis of the signal resulting from this process is studied in detail, and I also introduce a time-series data analysis technique that has not been applied to this field before but was introduced in another area very recently. The faster time-scale process has been attributed to the electrochemical excitation of the individual neurons in the brain that have been observed to cause a change in the scattering coefficient of the tissue. This is the other primary parameter that is measured by our frequency domain instrument. However, before this work it has not been clear how to go about to better localize these smaller fluctuations. I present a novel idea for improving spatial localization of macroscopic optical parameter fluctuations, and study the characteristics of this optical probe design using analytical solutions to the diffusion equation and Monte Carlo simulations that more appropriately represent the volume of excitation of the cortex neurons.","Made available in DSpace on 2015-09-25T20:02:35Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3017074.pdf: 6082108 bytes, checksum: 6466f7e60a0bb57d0d6dd8174da22cea (MD5) Previous issue date: 2001","Embargo set by: Seth Robbins for item 81746 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","103 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2001."]},{"key":"dc:title","label":"Title","values":["Spatial Localization and Temporal Analysis of Optical Property Fluctuations by Multiplexed Near -Infrared Photon Density Waves in Turbid Media: In Vitro and in Vivo Studies"]}]}],"canonical_facts":{"dc:contributor":["Gratton, Enrico"],"dc:creator":["Filiaci, Mattia Emidio"],"dc:date":["2015-09-25T20:02:35Z","10000-01-01","2001"],"dc:description":["Recently much attention has been given to the study of the processes in the human brain that lead to the changing of the optical parameters that characterize the tissue, measured by our frequency-domain instrumentation. These processes have been divided into two main categories with different time-scales. The slower one is mostly due to the fluctuations in the absorption coefficient caused by oxy- and deoxy-hemoglobin changes in the tissue. The temporal analysis of the signal resulting from this process is studied in detail, and I also introduce a time-series data analysis technique that has not been applied to this field before but was introduced in another area very recently. The faster time-scale process has been attributed to the electrochemical excitation of the individual neurons in the brain that have been observed to cause a change in the scattering coefficient of the tissue. This is the other primary parameter that is measured by our frequency domain instrument. However, before this work it has not been clear how to go about to better localize these smaller fluctuations. I present a novel idea for improving spatial localization of macroscopic optical parameter fluctuations, and study the characteristics of this optical probe design using analytical solutions to the diffusion equation and Monte Carlo simulations that more appropriately represent the volume of excitation of the cortex neurons.","Made available in DSpace on 2015-09-25T20:02:35Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 3017074.pdf: 6082108 bytes, checksum: 6466f7e60a0bb57d0d6dd8174da22cea (MD5) Previous issue date: 2001","Embargo set by: Seth Robbins for item 81746 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","103 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 2001."],"dc:identifier":["http://hdl.handle.net/2142/80464","(MiAaPQ)AAI3017074"],"dc:language":["eng"],"dc:subject":["Physics, Optics"],"dc:title":["Spatial Localization and Temporal Analysis of Optical Property Fluctuations by Multiplexed Near -Infrared Photon Density Waves in Turbid Media: In Vitro and in Vivo Studies"],"dc:type":["text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:14Z"}