{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/69907"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/69907","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Inelastic Analysis of Reinforced Concrete Beams Subjected to Combined Axial Force, Bending and Torsion","abstract":"The response of reinforced concrete members subjected to combined loading which includes torsion is investigated theoretically for a static monotonically increasing load. A unified model, which is an extension of the space truss model, is developed to solve this problem for rectangular, circular and slab sections. A nonlinear beam element which is based on the results from the space truss model is used in the analysis of grid structures on which torsion is known to be significant. By comparison with available experimental data as well as examination of the behavior of the model in extreme conditions, the use of the structural mechanism of the space truss model is verified. The application of the models to some typical torsional problems suggests the conclusion that the existence of torsion may have significant influence on the response of the structure, especially as it relates to the strength of the structure to support the applied load.","abstract_html":"The response of reinforced concrete members subjected to combined loading which includes torsion is investigated theoretically for a static monotonically increasing load. A unified model, which is an extension of the space truss model, is developed to solve this problem for rectangular, circular and slab sections. A nonlinear beam element which is based on the results from the space truss model is used in the analysis of grid structures on which torsion is known to be significant. By comparison with available experimental data as well as examination of the behavior of the model in extreme conditions, the use of the structural mechanism of the space truss model is verified. The application of the models to some typical torsional problems suggests the conclusion that the existence of torsion may have significant influence on the response of the structure, especially as it relates to the strength of the structure to support the applied load.","abstract_has_math":false,"creators":["Leung, Ming Biu"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-12-15T20:35:47Z","date_published":"2014-12-15T20:35:47Z","updated_at":"2026-07-22T22:26:01Z","subjects":["Engineering, Electronics and Electrical"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(UMI)AAI8218506"],"render_values":[{"text":"(UMI)AAI8218506","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/69907","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Leung, Ming Biu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-12-15T20:35:47Z","10000-01-01","1982"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Electronics and Electrical"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/69907","(UMI)AAI8218506"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The response of reinforced concrete members subjected to combined loading which includes torsion is investigated theoretically for a static monotonically increasing load. A unified model, which is an extension of the space truss model, is developed to solve this problem for rectangular, circular and slab sections. A nonlinear beam element which is based on the results from the space truss model is used in the analysis of grid structures on which torsion is known to be significant. By comparison with available experimental data as well as examination of the behavior of the model in extreme conditions, the use of the structural mechanism of the space truss model is verified. The application of the models to some typical torsional problems suggests the conclusion that the existence of torsion may have significant influence on the response of the structure, especially as it relates to the strength of the structure to support the applied load.","Made available in DSpace on 2014-12-15T20:35:47Z (GMT). No. of bitstreams: 1 8218506.pdf: 5054545 bytes, checksum: deca2c5c2ad00c5d32432b23c50a2d7c (MD5) Previous issue date: 1982","Embargo set by: Seth Robbins for item 70073 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","217 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 1982."]},{"key":"dc:title","label":"Title","values":["Inelastic Analysis of Reinforced Concrete Beams Subjected to Combined Axial Force, Bending and Torsion"]}]}],"canonical_facts":{"dc:creator":["Leung, Ming Biu"],"dc:date":["2014-12-15T20:35:47Z","10000-01-01","1982"],"dc:description":["The response of reinforced concrete members subjected to combined loading which includes torsion is investigated theoretically for a static monotonically increasing load. A unified model, which is an extension of the space truss model, is developed to solve this problem for rectangular, circular and slab sections. A nonlinear beam element which is based on the results from the space truss model is used in the analysis of grid structures on which torsion is known to be significant. By comparison with available experimental data as well as examination of the behavior of the model in extreme conditions, the use of the structural mechanism of the space truss model is verified. The application of the models to some typical torsional problems suggests the conclusion that the existence of torsion may have significant influence on the response of the structure, especially as it relates to the strength of the structure to support the applied load.","Made available in DSpace on 2014-12-15T20:35:47Z (GMT). No. of bitstreams: 1 8218506.pdf: 5054545 bytes, checksum: deca2c5c2ad00c5d32432b23c50a2d7c (MD5) Previous issue date: 1982","Embargo set by: Seth Robbins for item 70073 Lift date: Forever Reason: Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","Restricted to the U of I community idenfinitely during batch ingest of legacy ETDs","U of I Only","217 p.","Thesis (Ph.D.)--University of Illinois at Urbana-Champaign, 1982."],"dc:identifier":["http://hdl.handle.net/2142/69907","(UMI)AAI8218506"],"dc:subject":["Engineering, Electronics and Electrical"],"dc:title":["Inelastic Analysis of Reinforced Concrete Beams Subjected to Combined Axial Force, Bending and Torsion"],"dc:type":["text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:26:01Z"}